Expansion joints.<br />

Expansion joints shall be provided wherever directed by the engineer in charge, on<br />

where necessary as per standard specification and practice. The filler to be used<br />

shall be of approved material.<br />

1.8 Cement plaster.<br />

12 mm thick cement plaster in (1:4) proportion shall be applied on outside surface<br />

of all concrete works from 30cm below ground level up to top. The surface in<br />

contact with water will have 12 mm thick cement plaster of not less than (1:3)<br />

proportion with 3% water proofing compound. The concrete surface shall be<br />

properly hacked, washed, cleaned and applied with thick cement slurry before<br />

applying. All brick work unless otherwise specified will be plastered externally and<br />

internally with 12mm cement plaster (1:6) proportion.<br />

The plaster shall be protected from sun, rain and frost at the contractors expense by<br />

such means as the engineer may approve. To protect the plaster from the sun,<br />

ordinarily the whole surface shall be covered with wet sakes.<br />

The contractor shall keep the plaster continuously waited for a period of seven days<br />

after application.<br />

1.9 Flooring.<br />

Except where in otherwise specified flooring will have minimum 15cm thick sand<br />

filling, one brick flat soling and 75 mm thick PCC (1:2:4). In case flooring in raw<br />

water pump house 40 mm heavy duty patent stone flooring shall be provided<br />

directly over R.C.C. slab in strip placed in suitable manner to avoid construction<br />

cracks.<br />

1.10 Door and window.<br />

All windows shall be provided with aluminium grill of approved design.<br />

All rolling shutter shall be of approved make and size with pusher and pull operated<br />

properly fabricated including all accessories and necessary fitting of approved<br />

quality.<br />

All the doors and windows shall be painted with two coats of enamel paints over a<br />

coat of primer. Engineer in Charge shall approve the materials, the size, the shape<br />

and the fitting of doors and windows before put in position.<br />