After fixing the M.H. frame and cover locking arrangement shall be provided as per<br />

following unless specified in the wording of the item. The size of the M.S. flat shall<br />

be 50mm x 10mm with M.S. bar U shape of 16mm dia. The U shape M.S. bars<br />

shall be properly embedded in the RCC roof slab and anchored. The C.I. M.H.<br />

frame and cover and the locking arrangement after fixing shall be painted with<br />

anticorrosive black paint. The work shall be done to the entire satisfaction of the<br />

Engineer in charge.<br />

GTS : General Technical specification. Page 100