Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Integrated Routing System<br />
<strong>IXS</strong>-<strong>6700</strong><br />
<strong>IXS</strong>-<strong>6600</strong><br />
Universal LCD Remote Panel<br />
<strong>BKS</strong>-<strong>R6010</strong>
<strong>IXS</strong>-6000 Series Routing Systems<br />
— the Core Matrix in Your Production System<br />
It has always been important for the broadcast and video production industry to handle a<br />
wide array of signals at the optimal efficiency.<br />
Responding to this, <strong>Sony</strong> is proud to introduce a new-generation “hybrid” routing system, the<br />
<strong>IXS</strong>-6000 Series. Comprising two models, the <strong>IXS</strong>-<strong>6700</strong> and <strong>IXS</strong>-<strong>6600</strong>, this series can handle not<br />
only SD and HD video signals, but also audio, RS-422A, and time code within a single chassis.<br />
This gives both space- and cost-saving benefits.<br />
The <strong>IXS</strong>-6000 Series routers are equipped with a common Ethernet interface, allowing a<br />
sophisticated yet easy-to-configure network-based control system to be established.<br />
The well-proven S-BUS interface is also provided to enable easy integration into existing<br />
routing systems. Another advantage is the unique ability to integrate with <strong>Sony</strong>’s MVS-8000G<br />
and DVS-9000 switchers, bringing a number of great benefits such as bidirectional operational<br />
control, source name exchange, and tally management.<br />
In addition to the wide variety of optional control panels represented by the well-proven<br />
<strong>BKS</strong>-R1617A Multi-Display Control Unit that can be used with the <strong>IXS</strong> 6000 series routers,<br />
<strong>Sony</strong> is also introducing the <strong>BKS</strong>-<strong>R6010</strong> Universal LCD Remote Panel, which is equipped with<br />
LCD buttons for an enhanced level of operability.<br />
Packing these features into a compact chassis, the <strong>IXS</strong>-6000 Series Routing System is a<br />
cost-effective and smart solution for installation into a broad range of facilities, including<br />
those limited by space.<br />
FEATURES<br />
■ Multi-format Capability;<br />
Hybrid Routing System<br />
• Can handle HD-SDI and SD-SDI, AES/EBU,<br />
analog audio, RS-422A, and time code within<br />
a single chassis (a range of I/O modules are<br />
available to suit)<br />
• Video routing – up to 128 x 136 (<strong>IXS</strong>-<strong>6700</strong>)/<br />
64 x 68 (<strong>IXS</strong>-<strong>6600</strong>) matrix<br />
– Multiple bit-rate video signals (HD/SD or SD only)<br />
ranging from 143 Mb/s to 1.485 Gb/s<br />
– Re-clocking capability for multiple bit-rate signals<br />
including DVB-ASI<br />
• AES/EBU audio routing<br />
– Up to 256 x 272 (<strong>IXS</strong>-<strong>6700</strong>)/128 x 136 (<strong>IXS</strong>-<strong>6600</strong>)<br />
matrix by the use of TDM (Time Division Multiplexing)<br />
techniques<br />
– Optional Sampling Rate Converter module is available to<br />
handle asynchronous inputs<br />
Maximum Matrix size*<br />
<strong>IXS</strong>-<strong>6700</strong> <strong>IXS</strong>-<strong>6600</strong><br />
HD/SD Video 128 x 136 64 x 68<br />
SD Video 128 x 136 64 x 68<br />
AES/EBU Audio 256 x 272 128 x 136<br />
Analog Audio 64 x 64** 32 x 32**<br />
RS-422A 112 ports 56 ports<br />
Time Code 128 x 136 64 x 68<br />
* When the <strong>IXS</strong>-6000 Series is configured with a single signal format.<br />
** Stereo pairs<br />
■ Control System<br />
• Can be used as a primary station with<br />
enhanced control functions, eliminating the<br />
need for a separate external control unit<br />
• Has Powerful operational features such as Tieline,<br />
Virtual matrix, Input/output system<br />
protection, and Phantoms<br />
• Inputs and outputs can be freely assigned on<br />
up to 16 levels<br />
• Both S-BUS system and Ethernet control<br />
systems are available<br />
• Optional <strong>BKS</strong>-<strong>R6010</strong> Universal LCD Remote<br />
Panel for control of the <strong>IXS</strong>-6000 Series via<br />
either S-BUS system or Ethernet interface:<br />
- Equipped with a large LCD display for status<br />
indication (English, Chinese, and Japanese)<br />
- Multi-function buttons that are equipped with color<br />
TFT LCD displays to select sources, destinations, and<br />
levels<br />
- User-defined names can be displayed on the multi-<br />
function buttons (English, Chinese, and Japanese).<br />
- Source selection using a clickable selector knob<br />
- Easy setup via a web browser<br />
• Other optional control panels: <strong>BKS</strong>-R1617A<br />
Multi-Display Control Unit, <strong>BKS</strong>-R3216 Multi-BUS<br />
Control Unit, <strong>BKS</strong>-R3219A Universal Control Unit,<br />
and <strong>BKS</strong>-R3220 X-Y Control Unit
OPTIONS<br />
<strong>BKS</strong>-R1617A<br />
Multi-Display Control Unit<br />
■ High Reliability<br />
• High level of redundancy<br />
– Equipped with main and backup CPU board as standard<br />
– Equipped with redundant power supply units as standard<br />
(<strong>IXS</strong>-<strong>6700</strong>: four units – two for main and two for<br />
backup, <strong>IXS</strong>-<strong>6600</strong>: two units – one for main and one for<br />
backup)<br />
• Self-diagnostic functions<br />
– Monitors communication quality, link status, and backup<br />
CPU status<br />
– Detects mismatch of settings between main CPU and<br />
backup CPU<br />
– Detects crosspoint errors<br />
– Information on status/errors can be displayed on the<br />
router’s front panel<br />
■ Ease of Maintenance<br />
• Troubleshooting and software upgrades can<br />
be performed without interrupting system<br />
operations<br />
• Can keep a variety of logs such as System<br />
Status log and Command log (S-BUS, Ethernet,<br />
RS-422A, Internal Control)<br />
• Ethernet-based remote monitoring and<br />
maintenance can be obtained using the <strong>Sony</strong><br />
MMStation Remote Monitoring and<br />
Maintenance Software – an SNMP-compliant<br />
application<br />
<strong>BKS</strong>-R3216<br />
Multi-BUS Control Unit<br />
<strong>BKS</strong>-R3219A<br />
Universal Control Unit<br />
■ Compact and Lightweight Design<br />
• Compact chassis design:<br />
8RU (<strong>IXS</strong>-<strong>6700</strong>)/4RU (<strong>IXS</strong>-<strong>6600</strong>)<br />
• Low power consumption:<br />
approx. 550 W* (<strong>IXS</strong>-<strong>6700</strong>)/300 W** (<strong>IXS</strong>-<strong>6600</strong>)<br />
* 128 x 136 matrix, 1.485-Gb/s video with redundant<br />
power supply and CPU<br />
** 64 x 68 matrix, 1.485-Gb/s video with redundant<br />
power supply and CPU<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Format HD/SD Video SD Video AES/EBU Audio AES/EBU Audio Analog Audio RS-422A Time Code<br />
(D-sub) (BNC)<br />
Input IKS-V6010M IKS-V6010SD IKS-A6011 IKS-A6012 IKS-A6013 IKS-RS6010 IKS-TC6010<br />
HD/SD Digital Video<br />
Input Board,<br />
SD Digital Video<br />
Input Board,<br />
D-sub AES/EBU<br />
Input Board,<br />
BNC AES/EBU<br />
Input Board,<br />
Analog Audio Input<br />
Board, 8-stereo analog<br />
audio inputs<br />
RS-422A,<br />
Input Board,<br />
Time Code<br />
16 inputs<br />
16 inputs 16 inputs 32 inputs 16 inputs 7 inputs<br />
Sampling Rate Converter<br />
—<br />
IKS-A6015 Sampling Rate Converter Board,<br />
32 channels (stereo)<br />
—<br />
Matrix IKS-6030M Matrix Board<br />
Processor IKS-V6050M IKS-V6050SD<br />
HD/SD Video Router SD Video Router IKS-A6050 Audio/Data Router Processor Board<br />
Processor Board Processor Boardr<br />
Output IKS-V6060M IKS-V6060SD IKS-A6061 IKS-A6062 IKS-A6063 IKS-RS6060 IKS-TC6060<br />
HD/SD Digital Video<br />
Output Board,<br />
SD Digital Video<br />
Output Board,<br />
D-sub AES/EBU<br />
Output Board,<br />
BNC AES/EBU<br />
Output Board,<br />
Analog Audio Input<br />
Board, 8-stereo analog<br />
audio outputs<br />
RS-422A<br />
Output Board,<br />
Time Code<br />
17 outputs<br />
Specifications<br />
17 outputs 17 outputs 34 outputs 17 outputs 7 outputs<br />
Input/output connector BNC type D-sub BNC type D-sub 25-pin D-sub 9-pin BNC type<br />
(0.8 Vp-p ± 10%, 75 Ω) (balanced, 110 Ω) (unbalanced, 75 Ω) (female, balanced) (female) Time Code (LTC)<br />
Signal standard HD-SDI (SMPTE 292M) SD-SDI (SMPTE 259M) AES3-2003, AES3-2003, Analog audio RS-422A SMPTE 12M-1999<br />
SD-SDI (SMPTE 259M) SDTI (SMPTE 305M) AES-2id-1996 AES-3id-2001 (balanced) signal item 8.6<br />
SDTI (SMPTE 305M) (r2001) 6.3<br />
Data transfer rate 143 Mb/s to 1.485 Gb/s 143 Mb/s to 360 Mb/s 6.144 Mb/s (Sampling freq. 48 kHz) —<br />
Video re-clocking/ 143, 177, 270, 360, 143, 177, 270, Soft Switching (Linear PCM)<br />
540 Mb/s, 1.485/1.001,<br />
1.485 Gb/s<br />
360 Mb/s Synchronized Switching (Others) —<br />
S.R.C Input data<br />
transfer rate<br />
—<br />
4.928 to 27.648 Mb/s<br />
(Sampling freq. 38.5 kHz-216 kHz)<br />
—<br />
<strong>BKS</strong>-R3220<br />
X-Y Control Unit
SPECIFICATIONS<br />
<strong>IXS</strong>-<strong>6700</strong> <strong>IXS</strong>-<strong>6600</strong><br />
Main Frame 4 Power supply unit (2+2 redundancy), main and backup CPU boards 2 Power supply unit (1+1 redundancy), main and backup CPU boards<br />
General<br />
Power requirements 100 V to 240 V AC ±10%, 50/60 Hz<br />
Power consumption max. 550 W max. 300 W<br />
Operating temperture 5 to 40 °C (41 °F to 104 °F)<br />
Storage temperture -20 °C to 60 °C (-4 °F to 140 °F)<br />
Operational humidity 10 to 90% RH<br />
Dimensions (WxHxD) 440 x 354 x 520 mm (8RU) (17 3/8 x 14 x 20 1/2 inches) 440 x 176 x 520 mm (4RU) (17 3/8 x 7 x 20 1/2 inches)<br />
Mass 46 kg (fully loaded) (101 lb 7 oz) 26 kg (fully loaded) (57 lb 5 oz)<br />
Inputs/Outputs<br />
REMOTE 1 (S-BUS) <strong>Sony</strong> S-BUS, BNC type x 4 <strong>Sony</strong> S-BUS, BNC type x 3<br />
Distributed by<br />
MK10302V3IW08MAR<br />
Data transfer rate: 312 kb/s or 1250 kb/s Data transfer method: Bi-phase Space<br />
REMOTE 2 D-sub 9-pin (female) x 2, complies with RS-422A D-sub 9-pin (female) x 2*, complies with RS-422A<br />
Protocol: <strong>Sony</strong> Cart++ Data transfer rate: 38.4 kb/s<br />
REMOTE 3 D-sub 9-pin (male) x 1, complies with RS-232C signal standard for connecting a control terminal<br />
Timecode IN BNC type x 1<br />
ALARM OUT Mini D-sub 15-pin (female) x 1, Parallel, Open collector outputs, 6-ch D-sub 9-pin (female) x 1, Parallel, Open collector outputs, 4-ch*<br />
REF IN BNC type x 2 with loop-through output, tri-level sync or burst signal BNC type x 2, tri-level sync or burst signal<br />
WORD CLOCK BNC type x 2 with loop-through output BNC type x 1<br />
NETWORK RJ-45 x 2, 100BASE-TX<br />
* One of REMOTE 2 connecter is selectable between RS-422A and ALARM OUT.<br />
General<br />
<strong>BKS</strong>-<strong>R6010</strong><br />
Power requirements 100 to 120 V AC (for the U.S.A. and Canada) 100 to 240 V AC (for the other countries) 50/60 Hz<br />
Power consumption max. 72 W<br />
Operating temperture 5 to 40 °C (41 °F to 104 °F)<br />
Mass 2.2 kg (4 lb 14 oz)<br />
Control signal<br />
REMOTE 1 A/B <strong>Sony</strong> S-BUS, BNC type x2, Data transfer rate: 312 kb/s or 1250 kb/s, Data transfer method: Bi-phase Space<br />
REMOTE 2 D-sub 9-pin ×1, complies with RS-422A, Data transfer rate: 38.4 kb/s<br />
RS-232C D-sub 9-pin ×1, complies with RS-232C, Data transfer rate: 38.4 kb/s<br />
TC IN BNC type ×1<br />
NETWORK PJ-45 x1, 100 BASE-TX<br />
©2008 <strong>Sony</strong> Corporation. All rights reserved.<br />
Reproduction in whole or in part without written<br />
permission is prohibited.<br />
Features and specifications are subject to change without notice.<br />
All non-metric weights and measures are approximate.<br />
<strong>Sony</strong> and MMStation are trademarks of <strong>Sony</strong> Corporation.