Rack Card Calibration and Control – the controller in a module-based rack or chassis<br />

system often needs to identify what cards are installed, monitor key metrics like<br />

temperature, and track hot-swapped units. The 1 – Wire® memory, I/O, and<br />

temperature-sensor products solve this problem by providing a unique identity for every<br />

module in the system. The 1 – Wire® devices typically used include the DS2413,<br />

DS28EA00, DS2502, DS2505, DS2431, DS28EC20, DS2433, DS28E04, and DS28E01.<br />

PCB identification and authentication – factory-administered 64-bit serialization with<br />

embedded memory provides PCB/product labeling and storage of product information.<br />

Programmable features like OTP (One-Time Programmable) mode and write protection<br />

combine with SHA-1 based secure authentication to ensure that critical data cannot be<br />

altered once it is programmed. Storage of product characteristics, PCB<br />

hardware/software revision, maintenance records, and calibration constants are examples<br />

of typical usage. The 1 – Wire® devices typically used include the DS2401, DS2411,<br />

DS1963S, DS1992L, DS2502-E48, DS2502-E64, DS1982, DS1985, DS2431,<br />

DS28EC20, DS2433, DS28E01, and DS1961S.<br />

Accessory/Peripheral Identification and Control – typical applications include battery-<br />

pack and power-adapter identification, LED control, TEDS (Transducer Electronic Data<br />

Sheet) sensor identification/control, and consumable identification/control. The 1 –<br />

Wire® devices typically used include the DS2401, DS2411, DS2413, DS2502, DS2505,<br />

DS2431, DS28EC20, DS2433, and DS28E01.<br />

IP Protection, Secure Feature Control Clone Prevention – authentication solutions help<br />

OEMs (Original Equipment Manufacturers) protect product development and research<br />

31