X = OFF<br />

0 = ON<br />

E01: Indoor/Outdoor Communication Failure<br />

Lamps Quiet Timer Operation<br />

Condition (3) (2) (1)<br />

E01 X X 0<br />

Perform the following check<br />

Is the voltage of about 12 VDC<br />

Or more given between the terminals<br />

2 and 3 on the outdoor unit terminal plate<br />

(Serial Communication Line) ?<br />

(Fig. 1)<br />

Yes<br />

Cont.<br />

Voltmeter<br />

- +<br />

V<br />

Outdoor unit<br />

1 2 3 4 5 6<br />

1 2 3<br />

Indoor Unit<br />

Fig.1<br />

NO<br />

YES<br />

Defect or connection error<br />

In the inter-connecting wires.<br />

Power<br />

Fig. 2<br />

1 2 3<br />

Indoor Unit<br />

- V +<br />

Voltmete<br />

r<br />

1. Turn OFF the power and wait until the power lamp (LED)<br />

Of the outdoor unit controller is turned OFF.<br />

2. Disconnect the wire from the terminal 3 on the indoor unit<br />

Terminal plate. (Fig. 2)<br />

3. Turn ON the power.<br />

_<br />

Is the voltage of about 22 VDC to<br />

24 VDC given between the terminals<br />

2 and 3 on the indoor unit terminal plate<br />

(Serial Communication Line) ?<br />

(Fig. 2)<br />

NO<br />

Defect in the indoor unit<br />

P.C. board<br />

Outdoor Unit<br />

1 2 3 4 5 6<br />

X<br />

Power<br />

10