SI 1730 12/12/05<br />

Sauermann reference : SI1730SIUS11 or 23<br />

TECHNICAL PERFORMANCE DATA<br />

Mains supply 120V or 230V~ 60 Hz - 35 W<br />

Max flow rate 8 gph<br />

Max suction head From 4.9 to 8.2 ft according to<br />

mains supply (120V or 230V)<br />

Max discharge head 33 ft<br />

Detection levels On=0.67” Off=0.44” Alarm=0.83”<br />

Alarm contact NO - NC 8 A resistive – 250 V<br />

Thermal protection 194° F<br />

Sound level ≤ 42 dBA at 3.3 ft<br />

Pump dimensions L 3.7” x W 2.9” x H 2”<br />

Detection unit dimensions L 2.1” x W 1.6” x H 1.4”<br />

Weight (including box) ± 1.16 lbs (0.525 kg)<br />

Master Pack quantity 10 pieces<br />

GENERAL INFORMATIONs information<br />

Mini condensate pump specifically designed for air conditioning units with limited internal space.<br />

Kit content<br />

Piston pump bloc 8 gph<br />

Detection unit with float (SI2758)<br />

Connector and Connector protector<br />

Detector installation kit : blond rubber Ø 0.59”x1.38”, vent pipe Ø 0.16”x0.24” – 2.95”, selfadhesive<br />

mounting rail<br />

Description<br />

Reciprocating piston pump which first sucks in, then evacuates the condensation water.<br />

Consisting of a pump unit and a remote detection unit fitted with a 3 level float (on / off /<br />

alarm).<br />

Alarm contact normally closed or normally open that automatically cuts off the air<br />

conditioning system compressor or a solenoid valve or allows a light signal or a buzzer to<br />

operate.<br />

Thermal protection 194° F on the pump coil.<br />

Advantages<br />

Small size<br />

High performance<br />

Removable screw terminal<br />

APPLICATIONS<br />

Air conditioners up to 8.3 tons (30 kW)<br />

Wall split systems<br />

Fan coils<br />

Ceilling suspended units<br />

Ducted units.<br />

DIFFERENT INSTALLATION<br />

POSSIBILITIES<br />

1


ACCESSORIES<br />

TABLE OF TRUE FLOW RATE FOR SI 1730<br />

ACC 00105, ACC 00150<br />

Clear tubing 0.24” int.<br />

ACC 00105 : 16.4 ft in blister pack<br />

ACC 00150 : in 164 ft roll<br />

ACC 00205<br />

6 self-sealing fittings for condensate removal.<br />

The head losses defined Vertical Total tubing length<br />

In this table are calculated discharge 16 ft 33 ft 66 ft 98 ft<br />

With a Ø 0.24” int.<br />

Flexible pipework<br />

head (in gph) (in gph) (in gph) (in gph)<br />

3.3 ft 7.66 7.14 6.61 6.08<br />

SUCTION 6.6 ft 7.27 6.74 6.34 5.81<br />

HEIGHT 10.0 ft 6.74 6.34 5.81 5.42<br />

0ft 13.0 ft 6.21 5.81 5.29 5.02<br />

16.0 ft 5.55 5.15 4.76 4.36<br />

20.0 ft 4.36 3.97 3.70<br />

23.0 ft 3.70 3.30 3.04<br />

27.0 ft 3.04 2.64 2.38<br />

30.0 ft 2.38 1.98 1.72<br />

33.0 ft 1.59 1.32 1.06<br />

3.3 ft 6.34 5.81 5.55 5.29<br />

SUCTION 6.6 ft 5.81 5.55 5.29 5.02<br />

HEIGHT 10.0 ft 5.29 5.02 4.76 4.63<br />

3.3 ft 13.0 ft 4.49 4.36 4.23 4.10<br />

16.0 ft 3.70 3.57 3.57<br />

20.0 ft 3.04 2.91 2.91<br />

23.0 ft 2.64 2.51 2.38<br />

27.0 ft 2.12 1.98 1.85<br />

30.0 ft 1.59 1.46 1.32<br />

33.0 ft 0.93 0.80<br />

3.3 ft 5.29 5.02 4.76 4.63<br />

SUCTION 6.6 ft 4.49 4.36 4.23 4.10<br />

HEIGHT 10.0 ft 3.83 3.70 3.57 3.57<br />

6.6 ft 13.0 ft 3.04 2.91 2.91<br />

16.0 ft 2.64 2.51 2.38<br />

20.0 ft 2.12 1.98 1.85<br />

23.0 ft 1.59 1.46 1.32<br />

27.0 ft 1.06 0.93 0.80<br />

3.3 ft 3.83 3.70 3.57 3.57<br />

SUCTION 6.6 ft 3.17 3.04 2.91 2.91<br />

HEIGHT 10.0 ft 2.64 2.51 2.38<br />

8.20 ft 13.0 ft 2.12 1.98 1.85<br />

16.0 ft 1.59 1.46 1.32<br />

20.0 ft 1.06 0.93 0.80