8-4-2. Inspection Points for Each Part<br />
(1) Outdoor control circuit board<br />
Refer to 8-3-1. Checking the outdoor unit.<br />
NOTE<br />
Others<br />
Inspection<br />
points<br />
Breaker<br />
Problems<br />
Refrigerant gas pressure<br />
Indoor unit<br />
Do not remove or insert the outdoor control circuit board connector when power is being supplied to it.<br />
(The controller will be damaged.)<br />
(2) Fuse<br />
Check it visually or the continuity with a tester.<br />
(3) Compressor<br />
Check for an open circuit in the compressor coil winding.<br />
(4) Compressor protective sensor (compressor discharge temperature thermistor)<br />
Check that the senseor is securely contained in the thermostart holder.<br />
(5) Coil thermistor<br />
Check that the sensor is securely contained in the thermostat holder.<br />
Indoor unit does not operate.<br />
Operation lamp blinking.<br />
Operation lamp does not illuminate.<br />
Indoor fan dose not turn.<br />
Outdoor unit does not operate.<br />
75<br />
Outdoor fan dose not turn.<br />
Outdoor unit Others<br />
The compressor (only) does not<br />
operate.<br />
The compressor stops on occasion.<br />
The compressor speed does not<br />
increase.<br />
The electric expansion valve does<br />
not operate.<br />
Does not cool or cooling<br />
performance is inadequate.<br />
No. of<br />
Inspection<br />
Points for<br />
Each part<br />
(8)<br />
(9)