Outdoor Unit : CU-4KS24NBU<br />

Indoor Unit : CS-MKS9NKU × 3<br />

Power Supply : 230V Single Phase 60Hz<br />

RATING CAPACITY: 25,400 BTU/h AIR FLOW RATE: 777 CFM<br />

INDOOR OUTDOOR<br />

ENT. TEMP. o F ( o C) AMBIENT TEMP. o F ( o < Cooling Capacity (Low Ambient) ><br />

C)<br />

WB DB 15 25 35 45 55<br />

(-9.4) (-3.9) (1.7) (7.2) (12.8)<br />

TC 25,470 25,420 25,470 25,670 25,610<br />

72 (22.2) SHC 19,250 25,420 19,250 19,410 19,410<br />

59 76 (24.4) SHC 21,970 25,420 21,970 22,120 22,120<br />

(15.0) 80 (26.7) SHC 24,840 25,420 24,840 24,840 24,840<br />

84 (28.9) SHC 25,470 25,420 25,470 25,670 25,610<br />

88 (31.1) SHC 25,470 25,420 25,470 25,670 25,610<br />

TC 25,540 25,590 25,780 26,160 26,210<br />

72 (22.2) SHC 15,780 25,590 15,780 15,940 16,090<br />

63 76 (24.4) SHC 18,350 25,590 18,500 18,650 18,650<br />

(17.2) 80 (26.7) SHC 21,220 25,590 21,370 21,520 21,520<br />

84 (28.9) SHC 23,930 25,590 23,930 24,080 24,230<br />

88 (31.1) SHC 25,540 25,590 25,780 26,160 26,210<br />

TC 25,380 25,550 25,930 26,510 26,700<br />

72 (22.2) SHC 12,010 25,550 12,310 12,470 12,620<br />

67 76 (24.4) SHC 14,730 25,550 15,030 15,180 15,330<br />

(19.4) 80 (26.7) SHC 17,600 25,550 17,750 18,050 18,050<br />

84 (28.9) SHC 20,160 25,550 20,460 20,610 20,760<br />

88 (31.1) SHC 22,880 25,550 23,180 23,330 23,480<br />

TC 24,930 25,240 25,840 26,690 27,040<br />

72 (22.2) SHC 8,240 25,240 8,540 8,840 9,000<br />

71 76 (24.4) SHC 10,960 25,240 11,260 11,560 11,710<br />

(21.7) 80 (26.7) SHC 13,670 25,240 13,970 14,280 14,430<br />

84 (28.9) SHC 16,390 25,240 16,690 16,990 17,140<br />

88 (31.1) SHC 19,100 25,240 19,410 19,710 19,860<br />

TC 24,210 24,680 25,530 26,670 27,190<br />

75 76 (24.4) SHC 7,190 24,680 7,640 7,940 8,240<br />

(23.9) 80 (26.7) SHC 10,050 24,680 10,500 10,810 10,960<br />

84 (28.9) SHC 12,620 24,680 13,070 13,520 13,670<br />

88 (31.1) SHC 15,330 24,680 15,780 16,090 16,390<br />

TC : Total Cooling Capacity (BTU/h) SHC : Sensible Heat Capacity (BTU/h)<br />

NOTE<br />

1. Above data does not take Freeze Prevention Protection during cooling operation into account.<br />

For this reason, the value may vary from the actual cooling characteristics.<br />

2. Above data represents the value when the operation frequency of a compressor is fixed.<br />