UNIVERSITY OF CALIFORNIA SAN FRANCISCO, CLINICAL LABORATORIES<br />

6. Validate and print control and patient results.<br />

7. Save the database to the designated flash drive.<br />

8. Perform Daily Shut-Down procedure.<br />

9. For optimal performance, it is important to perform routine maintenance as described in the<br />

LIAISON User Manual. Detailed instructions may be found in the DisSorin LIAISON Maintenance<br />

procedure.<br />

SPECIMEN DILUTION PROCEDURES<br />

Specimens with a 25 OH <strong>Vitamin</strong> D <strong>Total</strong> result <strong>of</strong> >150 ng/mL will be flagged as “>>”. Samples<br />

should be diluted with LIAISON 25 OH <strong>Vitamin</strong> D TOTAL Specimen Diluent. Note that all lots <strong>of</strong><br />

specimen diluent are interchangeable between LIAISON 25 OH <strong>Vitamin</strong> D TOTAL <strong>Assay</strong> kit lots.<br />

Manual dilutions should be done as follows:<br />

a. A dilution <strong>of</strong> one part patient to 3 parts diluent is recommended, resulting in a 1:4 dilution.<br />

b. Mix specimen diluent thoroughly by gentle inversion prior to use.<br />

c. Add 75 µL <strong>of</strong> patient sample to 225 µL <strong>of</strong> specimen diluent.<br />

d. Mix well or vortex gently.<br />

X. RESULTING/REPORTABLE RANGE<br />

The predefined Master Curve is adjusted to a new instrument-specific curve using the two calibrators<br />

supplied in the reagent integral via the bar codes on the reagent integral label.<br />

Some results may contain information in the flags column <strong>of</strong> the report. For a description <strong>of</strong> the flags<br />

that may appear refer to the posted reference table or to the LIAISON Quick Guide Appendix, page<br />

25.<br />

ANALYTICAL MEASUREMENT RANGE & REPORTABLE RANGE<br />

The analytical measurement range for the DiaSorin LIAISON 25 OH <strong>Vitamin</strong> D <strong>Total</strong> <strong>Assay</strong> is 4<br />

ng/mL to 150 ng/mL.<br />

The lowest reportable value is 4 ng/mL, based on an inter-assay precision that approximates 20% CV<br />

(functional sensitivity). Values below 4 ng/mL should be reported as