Report in English with a Dutch summary (KCE reports 45A)
Report in English with a Dutch summary (KCE reports 45A)
Report in English with a Dutch summary (KCE reports 45A)
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>KCE</strong> <strong>reports</strong> vol.45 Screen<strong>in</strong>g for Colorectal Cancer 65<br />
Table 14: Advantages and disadvantages of iFOBT compared <strong>with</strong><br />
gFOBT<br />
Advantages of fecal immunochemical test (iFOBT) compared <strong>with</strong> gFOBT<br />
Improved<br />
specificity<br />
Potential<br />
<strong>in</strong>crease <strong>in</strong><br />
patient<br />
compliance<br />
iFOBTs will not react <strong>with</strong> non-human hemoglob<strong>in</strong>, vitam<strong>in</strong>s, drugs, or<br />
peroxidase from food sources. They also showed to be non-reactive <strong>with</strong><br />
blood from the upper gastro<strong>in</strong>test<strong>in</strong>al tract provided bleed<strong>in</strong>g is occult.<br />
S<strong>in</strong>ce no dietary restrictions are needed, iFOBT may be more acceptable to<br />
the consumer than current gFOBT tests.<br />
Disadvantages of an fecal immunochemical test (iFOBT) compared <strong>with</strong> gFOBT<br />
Limited cl<strong>in</strong>ical<br />
test<strong>in</strong>g<br />
Same<br />
sensitivity<br />
limitations<br />
More<br />
expensive<br />
Regional<br />
resources<br />
Colonoscopy<br />
resources limited<br />
Colonoscopy<br />
resources readily<br />
available<br />
No prospective, controlled trials of iFOBT screen<strong>in</strong>g and colorectal cancer<br />
<strong>in</strong>cidence or mortality outcomes have been reported. However, if iFOBTs<br />
perform at least as well as gFOBT, it is likely that iFOBTs used for CRC<br />
screen<strong>in</strong>g would have at least the same efficacy <strong>in</strong> decreas<strong>in</strong>g colon cancer<br />
mortality as gFOBTs 270.<br />
While iFOBTs have advantages over gFOBTs, they are still tests for occult<br />
blood, which may leak <strong>in</strong>termittently and may occur from sources <strong>in</strong> the<br />
colon and rectum other than cancers or large adenomas. Data <strong>in</strong>dicate that<br />
the problem for detection created by <strong>in</strong>termittent bleed<strong>in</strong>g is less marked<br />
<strong>with</strong> immunochemical than <strong>with</strong> guaiac tests because higher test sensitivity<br />
is not accompanied by significant degradation of specificity, as is the cause<br />
<strong>with</strong> guaiac tests.<br />
In addition, because bleed<strong>in</strong>g from adenomas occurs <strong>in</strong>frequently, the<br />
potential for CRC prevention through adenoma detection and removal is<br />
likely to be lower <strong>with</strong> this and all FOBT methods than <strong>with</strong> endoscopic<br />
and imag<strong>in</strong>g screen<strong>in</strong>g modalities. However when used annually, as<br />
recommended, the program sensitivity of FOBT is very high.<br />
See Table 15<br />
Table 15 lists available FOBT test kits <strong>in</strong> Belgium 274, leav<strong>in</strong>g some choice<br />
depend<strong>in</strong>g on availability of regional colonoscopy resources.<br />
Table 15: Choice of FOBT depend<strong>in</strong>g on colonoscopy resources<br />
Recommended<br />
FOBT<br />
Guaiac test <strong>with</strong><br />
high specificity<br />
Fecal<br />
Immunochemical<br />
test (FIT)<br />
Guaiac test <strong>with</strong><br />
high sensitivity<br />
Trade name Belgian supplier Price per<br />
test round<br />
(VAT <strong>in</strong>cl.)<br />
Hemoccult® II Laméris 2,06<br />
Instant-View®<br />
Hemostick®<br />
Actim Fecal<br />
Blood®<br />
Hemoccult®<br />
Sensa®<br />
Obelis<br />
Ventec<br />
Lucron<br />
Bioproducts<br />
Laméris N.V.<br />
± 7<br />
2,14<br />
The Instant View FOBT II test comes <strong>in</strong> a set of fecal collection tubes, pre-filled<br />
<strong>with</strong> extraction buffer, <strong>with</strong> sampl<strong>in</strong>g stick and correspond<strong>in</strong>g one-step lateral<br />
flow chromatographic immunoassay test cassettes (Instant View FOBT II casette