5. Results<br />
This section is structured around an analysis of each sample in turn. Hence there is a<br />
comparison of defects on that sample between the various X-ray techniques, and a<br />
comparison with the optical micrographs. The optical micrographs are referred to as<br />
Reichert, the microscope used.<br />
5.1 Results for Sample 1<br />
Sample I contains partially retlowed solder joints.<br />
Figure Machine used Defects<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
21<br />
22<br />
Glenbrook<br />
Glenbrook<br />
Nicolet<br />
X-tekperpend.<br />
X-tekangled<br />
HP Four Pi 50x<br />
Reichert<br />
Reichert<br />
Reichert<br />
Reichert<br />
Reichert<br />
Partially reflowed solder joints<br />
Partially reflowed solder joints<br />
Partially reflowed solder joints<br />
Partially reflowed solder joints<br />
Partially reflowed solder joints<br />
Partially reflowed solder joints<br />
Non-reflow of solder paste<br />
Partial reflow of solder paste<br />
Complete reflow of solder paste<br />
Incomplete melting of ball<br />
Non-reflow of solder paste<br />