Attachment 2<br />

Page 15<br />

2.3.2 Arrangements 3 and 4 above require the use of a designed circuit. Therefore, nondesigned<br />

Loops such as the SL1 voice grade and UCL-ND may not be ordered in<br />

these cases.<br />

2.3.3 If no alternate facility is available, and upon request from BHN, and if agreed to<br />

by both Parties, AT&T may utilize its Special Construction (SC) process to<br />

determine the additional costs required to provision facilities. BHN will then have<br />

the option of paying the one-time SC rates to place the Loop.<br />

2.4 Network Interface Device<br />

2.4.1 The NID is defined as any means of interconnection of the End User’s premises<br />

wiring to AT&T’s distribution plant, such as a cross connect device used for that<br />

purpose. The NID is a single-line termination device or that portion of a multiple<br />

line termination device required to terminate a single line or circuit at the<br />

premises. The NID features two independent chambers or divisions that separate<br />

the service provider’s network from the End User’s premises wiring. Each<br />

chamber or division contains the appropriate connection points or posts to which<br />

the service provider and the End User each make their connections. The NID<br />

provides a protective ground connection and is capable of terminating cables such<br />

as twisted pair cable.<br />

2.4.2 AT&T shall permit BHN to connect BHN’s Loop facilities to the End User’s<br />

premises wiring through the AT&T NID or at any other technically feasible point.<br />

2.4.3 Access to NID<br />

2.4.3.1 BHN may access the End User’s premises wiring by any of the following means<br />

and BHN shall not disturb the existing form of electrical protection and shall<br />

maintain the physical integrity of the NID:<br />

2.4.3.1.1 In Georgia, Kentucky and Florida, AT&T shall allow BHN to connect its Loops<br />

directly to AT&T’s multi-line residential NID enclosures that have spare<br />

terminations available or, in those states where the Commission has so ordered,<br />

BHN can connect to terminations that currently have loops attached to them but<br />

that are not currently used by AT&T or any other telecommunications carriers to<br />

provide service to the premises.<br />

2.4.3.1.2 Where an adequate length of the End User’s premises wiring is present and<br />

environmental conditions permit, either Party may remove the customer premises<br />

wiring from the other Party’s NID and connect such wiring to that Party’s own<br />

NID, provided that it has received the appropriate consent from the End User and<br />

has provided reasonable advanced notice to the other party.<br />

2.4.3.1.3 Either Party may enter the subscriber access chamber or dual chamber NID<br />

enclosures for the purpose of extending a connect divisioned or spliced jumper<br />