ATACHMENT6: 251(C)(3) UNE/SOUTHWESTERN BELL TELEPHONE, L.P.<br />

SBC TEXAS/CLEC JOINT PETITIONERS<br />

PAGE 17 of 42<br />

082505<br />

environment where the Inside Wire subloop is owned or controlled by SBC Texas. The Parties acknowledge<br />

and agree that a transmission facility to a CMRS facility does not have to be unbundled. The local loop<br />

UNE includes all features, functions and capabilities of the transmission facility, including attached<br />

electronics (except those electronics used for the provision of advanced services, such as Digital Subscriber<br />

Line Access Multiplexers), and CLEC requested line conditioning (subject to applicable charges in Appendix<br />

Pricing). The local loop UNE includes, but is not limited to DS1, DS3, fiber, and other high capacity loops to<br />

the extent required by applicable law.<br />

4.2.1 SBC TEXAS must provide timely access to unbundled loops offered under the terms of this agreement.<br />

SBC TEXAS’ timeliness will be measured as required by the provisions in Attachment: Performance<br />

Measurements.<br />

4.3 SBC TEXAS shall provide at the rates, terms, and conditions set out in this Attachment and Attachment<br />

Pricing, the types of UNE loops in sections 4.3.1- 4.3.6. When CLEC orders an 251(c)(3) Unbundled loop,<br />

CLEC will be provided a termination on whatever demarcation device, if any, connects the loop to the<br />

customer premises or a compatible interface device or NID on a SBC TEXAS owned or controlled telephone<br />

pole where the CLEC Radio Port connects with SBC TEXAS’ network, without additional charge.<br />

4.3.1 The standard for 2-Wire analog loop is loss not exceeding 8 dB. SBC will offer 2-Wire analog loop not to<br />

exceed 5dB as an option which supports analog voice frequency, voice band services with loop start<br />

signaling within the frequency spectrum of approximately 300 Hz and 3000 Hz.<br />

4.3.2 The 4-Wire analog loop provides a non-signaling voice band frequency spectrum of approximately 300 Hz to<br />

3000 Hz. The 4-Wire analog loop provides separate transmit and receive paths.<br />

4.3.3 The 2-Wire 160 Kbps digital interface loop (ISDN-BRI) facilities transmission of digital signals at 160 Kbps<br />

and provides 2 B plus D channels.<br />

4.3.4 Intentionally Left Blank.<br />

4.3.5 A DS1 Digital Loop 1.544 Mbps digital interface loop facilities transmission of digital signals at 1.544 Mbps<br />

and terminates in a 4-wire electrical interface at both ends.<br />

4.3.5.1 DS1 loops (where they have not been Declassified and subject to caps set forth in Section 4.3.6.2).<br />

However, notwithstanding this Section 4.3.5.1, access to 251(c)(3) UNEs is provided under this Agreement<br />

over such routes, technologies, and facilities as SBC TEXAS may elect at its own discretion.<br />

4.3.6 DS1 UNE Digital Loops will be offered and/or provided only where such Loops have not been Declassified.<br />

4.3.6.1 The procedures set forth below will apply in the event DS1 Digital Loops (DS1) are or have been<br />

Declassified.<br />

4.3.6.2 DS1 Loop “Caps”<br />

SBC TEXAS is not obligated to provide to CLEC more than ten (10) DS1 251(c)(3) UNE loops per<br />

requesting carrier to any single building in which DS1 Loops have not been otherwise Declassified;<br />

accordingly, CLEC may not order or otherwise obtain, and CLEC will cease ordering 251(c)(3) Unbundled<br />

DS1 Loops once CLEC has already obtained ten DS1 251(c)(3) UNE Loops at the same building. If,<br />

notwithstanding this Section, CLEC submits such an order, at SBC TEXAS’ option it may accept the order,<br />

but convert any requested DS1 251(c)(3) UNE Loop(s) in excess of the cap to Special Access, and