09.08.2013 Views

Lighting controls

Lighting controls

Lighting controls

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

PHL-H11_INT.QXD 16-07-2004 10:42 Pagina 11.1<br />

<strong>Lighting</strong> <strong>controls</strong>


PHL-H11_INT.QXD 16-07-2004 10:42 Pagina 11.2<br />

11.2 LIGHTING CONTROLS


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.3<br />

Health and well being – Total cost of ownership<br />

The benefits of lighting <strong>controls</strong><br />

Modern lighting <strong>controls</strong> deliver a range of benefits, most of which<br />

can be measured in real improvements to the profits of a business.<br />

From straightforward energy savings, through reduced maintenance<br />

costs to potential increases in productivity, lighting <strong>controls</strong> have<br />

clearly demonstrated their worth.<br />

Over the past 25 years Philips lighting <strong>controls</strong> have developed a full<br />

range of solutions designed to deliver these benefits.<br />

Energy Saving<br />

No business likes to be seen to be wasteful. <strong>Lighting</strong> <strong>controls</strong> ensure<br />

that lighting is only provided when and where it is needed.Advanced<br />

sensors are used to integrate daylight and to detect occupancy.These<br />

solutions have been shown to reduce lighting use by as much as 75%.<br />

Result-no obvious waste or compromise of comfort.<br />

Installation Cost Saving<br />

Occupancy sensors and wireless infra-red <strong>controls</strong> avoid the use of<br />

wired switches. Control products compatible with a ‘plug-in’<br />

approach to installation can save up to 70% of the ‘on-site’ labour<br />

time.And these savings continue during the life of the building<br />

whenever changes are needed.<br />

Comfort<br />

In business today the provision of a comfortable environment for<br />

people to learn, work, shop, eat, rest and play is vital for success.<br />

With Philips’ <strong>controls</strong>, the lighting can be set to suit the task, the<br />

experience, individual preferences and tge required mood – and then<br />

readily change them as well.<br />

Safety<br />

There is an increasing awareness of safety and well being, with a<br />

growing emphasis on the importance of emergency lighting.<br />

Flexibility<br />

It is said that the only certainty in life is that things will change.Any<br />

building that cannot be readily adapted to changing business needs<br />

and use is not acceptable today. Philips lighting <strong>controls</strong> are designed<br />

to facilitate change-rapidly and effectively–whatever the application.<br />

Meeting Legislation<br />

Climate change, as well as health and safety are provoking<br />

governments into making more and more regulations, standards and<br />

legislation. Often lighting alone will not easily meet these demands<br />

without the addition of a control solution. In this field, Philps lighting<br />

<strong>controls</strong> has unrivalled knowledge and experience to share.<br />

Maintenance<br />

The easier it is to maintain a lighting installation the lower the cost<br />

of ownership.A Philips lighting management solution can extend lamp<br />

life, provide regular maintenance schedules and report on the<br />

condition of emergency lights. Our lighting management solutions<br />

ensure that exit route lighting is maintained during periods of<br />

occupancy and emergency lighting is effectively tested and<br />

monitored.<br />

LIGHTING CONTROLS<br />

11.3


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.4<br />

<strong>Lighting</strong> <strong>controls</strong> – Key features<br />

E<br />

Automatic control<br />

1. Movement detection<br />

To control lighting within a specific area, sensing of occupancy by<br />

movement detection ensures that lights are activated only when<br />

needed.<br />

2. Daylight linking<br />

Natural light is energy-saving and beneficial to individual users. Light<br />

output can respond to daylight conditions, maintaining a constant level<br />

of indoor lighting and ensuring comfort at all times.<br />

3.Time schedule<br />

Daily programming of the management of lighting installations enables<br />

the correct lighting levels to be achieved at all times, by changing<br />

lighting levels, by switching lights on and off or by adjusting the way<br />

control systems respond to other devices.<br />

Manual control<br />

4. Pushbuttons/wall switches<br />

<strong>Lighting</strong> Control systems can also be operated manually by connecting<br />

conventional wall switches or pushbuttons to inputs in the lighting<br />

control module.<br />

5. Infrared remote control<br />

In offices and meeting rooms where the lighting requirements change<br />

frequently, wireless infrared control offers the flexibility to set the<br />

lighting, and change it at any time.<br />

6. PC control via IT network (TCP/IP)<br />

For high-level lighting management, the control system can be linked to<br />

a LAN. This option gives individual users’ control over their local<br />

working environment.<br />

7.Telephone handset control (via PABX)<br />

To enhance individual comfort, telephones can be connected to a<br />

lighting management system for a cost-effective way of letting users<br />

control their local lighting.<br />

Monitoring<br />

8. Hours run logging<br />

Keep track of lamp hours and produce precisely targeted relamping<br />

schedules and detailed departmental cost allocations.<br />

9. Emergency lighting test and monitor<br />

<strong>Lighting</strong> management systems offer a reliable way to carry out statutory<br />

testing of emergency and exit lighting, without interfering with the<br />

normal operation of standard luminaires.<br />

10. Current lighting status<br />

The ability to get a real-time view of the status of all the lights in a<br />

building on a floor-by-floor basis enhances effective facility management.<br />

11.4 LIGHTING CONTROLS<br />

DMX<br />

<strong>Lighting</strong> effects<br />

11. Maintained illuminance<br />

Set desired light levels and maintain them throughout the life of the<br />

lamp to achieve significant cost savings.<br />

12. Dimming control<br />

As more and more light sources can be economically dimmed, lighting<br />

<strong>controls</strong> need to provide both switching and dimming capabilities.<br />

13. Grouping of lighting circuits<br />

Managing a comfortably lit interior often involves one group of lights<br />

influencing the status of another circuit.<br />

14. Corridor linking<br />

Holding lights on in common circulation areas and corridors during all<br />

occupied hours is an important contribution to comfort and safety.<br />

15. Scene-setting<br />

To meet the needs of different tasks, events or moods, a selection of<br />

lighting scenes can be created, stored and recalled at the touch of a<br />

button.<br />

16. Control of any lighting type<br />

As lighting designs often require multiple types of lamps, <strong>Lighting</strong><br />

Controls provide the freedom to choose any suitable lamps.<br />

17. Colour changing<br />

The ability to change the colour temperature of a lighting installation<br />

makes it possible to eather create a more comfortable working<br />

environment or introduce dynamic lighting effects in architecture.<br />

System connectivity<br />

18. Link to other building <strong>controls</strong><br />

The <strong>Lighting</strong> Controls product range includes numerous possibilities for<br />

different building control and management systems to share information<br />

and functions.<br />

19. Full LonWorks ® Interoperability<br />

Achieve seamless integration into building-wide control systems by<br />

using a standard network protocol.<br />

20. Digital Adressable <strong>Lighting</strong> Interface<br />

The Digital Addressable <strong>Lighting</strong> Interface is the latest standard control<br />

interface for high-frequency electronic ballasts. With this new<br />

technology, control circuits are completely independent of supply<br />

wiring.<br />

21. DMX interface<br />

The standard protocol for the audio/visual and theatre industry. This<br />

interface links complex lighting scenes to presentations and displays.


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.5<br />

<strong>Lighting</strong> <strong>controls</strong> – System selection matrix<br />

Philips offers a range of innovative lighting control products that<br />

meet the demands of many sizes and types of application.Whether<br />

the project is a large HQ office building, requiring a full lighting<br />

management system, or a small refurbishment job involving a couple<br />

of rooms, there is a Philips lighting control to suit the application.<br />

When matching your project to our lighting control products use<br />

the following criteria as your initial guide to product selection:<br />

E<br />

DMX<br />

Systems Stand alone Luminaire based<br />

Helio Lightmaster Scenio 100 Scenio<br />

Trios<br />

MultiDim<br />

Occuswitch<br />

Intelligent<br />

luminaires<br />

Linesense<br />

Automatic control page 11.15 page 11.16 page 11.27 page 11.31<br />

page<br />

11.30/11.26<br />

page 11.10 page 11.6 page 11.28<br />

Movement detection • • • • • • • •<br />

Daylight linking • • • • •<br />

Time schedule • • •<br />

Manual control<br />

Push buttons/switches • • • • • •<br />

Infrared remote control • • • • • • •<br />

PC control • • o<br />

Telephone control via PABX o<br />

Monitoring<br />

Hours run logging o •<br />

Emergency testing and logging o •<br />

<strong>Lighting</strong> effects<br />

Maintained illuminance • • • • •<br />

Switching and dimming • • • • • • •<br />

Grouping functionality • • • •<br />

Corridor linking • •<br />

Scene setting • • • • • •<br />

Control of any lighting type • • • • • •<br />

Colour changing o o • •<br />

System Connectivity<br />

• The functionality required – dimming, flexibility ….<br />

• The scale of the project (and hence its budget…)<br />

• The application – office, hotel, shop, industry, etc.<br />

Other factors to bear in mind include the choice of lighting design as<br />

well as any requirement for local user <strong>controls</strong> and/or occupancy<br />

response.<br />

Link to other building mgt. syst. • • •<br />

Full LonWorks ® interoperability •<br />

Digital Adressable <strong>Lighting</strong> Interface • • o • • •<br />

DMX interface •<br />

• standard option o project special<br />

LIGHTING CONTROLS 11.5


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.6<br />

Luminaire based and basic solutions<br />

Philips intelligent luminaires –<br />

The simplest way to lighting control<br />

To increase comfort, energy saving and flexibility in offices, Philips has<br />

incorporated miniature lighting <strong>controls</strong> within the luminaires.<br />

Philips <strong>Lighting</strong> offers a choice of intelligent luminaire solutions that<br />

provide a wide range of functions such as daylight linking, movement<br />

detection, remote control and scene setting with energy savings of<br />

up to 70%. Intelligent luminaires enable lighting control to be applied<br />

in a building at any stage of a project.The sensor-controller<br />

combination within the luminaire has little impact, or none at all, on<br />

the electrical installation.<br />

Omnisense – All intelligence in one<br />

Primarily designed for cellular and smaller open plan offices,<br />

Omnisense can also be applied in other areas such as meeting<br />

rooms, toilets and storage rooms. By using the benefits of digital<br />

technology, Omnisense provides 10 pre-programmed modes to<br />

match a variety of applications quickly and easily. Each mode includes<br />

a varies parameters such as delay times and switching behaviour. In<br />

addition to daylight regulation and movement detection, infrared<br />

remote control enables users to interact with their environment:<br />

switch, dim or select preset lighting levels or scenes. Omnisense<br />

functionality can be changed easily so that its behaviour can be<br />

adapted to new situations.<br />

11.6 LIGHTING CONTROLS<br />

Occulux – Movement-dependent daylight regulation<br />

As a combination of a state-of-the-art light sensor and a miniature<br />

movement detector, Occulux regulates lighting levels depending on<br />

the amount of daylight entering a room and on occupation.The<br />

increasing need for flexibility means that lights often remain on<br />

unnecessarily. On the other hand, turning lights off in certain areas of<br />

an open plan office can create an unpleasant visual impression.<br />

Occulux therefore dims light down to a minimum lighting level when<br />

an area is unoccupied.The result is a constant, pleasant lighting level<br />

for office workers with a maintained adjustable minimum, enabling<br />

owners to benefit from considerable savings on energy costs of up<br />

to 50%.<br />

Luxsense – Daylight-dependent regulation option<br />

Luminaires with this option contain a unobtrusive light sensor,<br />

regulating light to the required level depending on the amount of<br />

daylight. Energy saving results from both the use of daylight and the<br />

compensation of the over-design effect (maintained illuminance).<br />

With today’s efficient lamps and optics, the compensation of the<br />

over-design is very effective, particularly in retrofit projects.Average<br />

energy savings can reach up to 35%. Luxsense is also available as a<br />

separate product for both TL5 and TL-D luminaires.


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.7<br />

Occuswitch – <strong>Lighting</strong> control the easy way<br />

The Occuswitch is a very simple occupancy type controller that<br />

provides automatic switching of lighting loads of up to 10A.A built-in<br />

adjustable time delay allows the lights to remain on after occupancy<br />

for a selected period of time.An optional light sensor is also built-in<br />

so that if the natural daylight conditions are sufficient the lights will<br />

not switch on thus saving more energy.<br />

The Occuswitch distinguishes itself in design, quality and ease of<br />

installation; it is simply positioned in the middle of the room or area,<br />

the mains power supply wired directly to it and the luminaire circuit<br />

wired from it. Simplicity at its best! Occuswitch is ideally suited for<br />

those areas that are infrequently occupied and where dimming is not<br />

required - such as washrooms, stores, lobbies, corridors, cellular<br />

offices and meeting rooms.A version with manual IR remote<br />

override control is also available.<br />

Occuswitch<br />

LIGHTING CONTROLS 11.7


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.8<br />

<strong>Lighting</strong> <strong>controls</strong> Omnisense, Occulux, Luxsense<br />

11.8 LIGHTING CONTROLS<br />

LRI1661<br />

Omnisense<br />

- Easy selection of 10 building application modes<br />

with commissioning tool IRT8099<br />

- Mounting height: approx. 3 m<br />

- Default setting light level: 500 - 600 lux<br />

- Easy adjustment of required light level with<br />

commissioning tool<br />

- Movement detection area 20 m 2<br />

- Master-slave installation: up to 7 DALI luminaires<br />

can be slaved to 1 luminaire equipped with<br />

Omnisense provided they all remain in the<br />

movement detection area<br />

- Reliable Philips RC5 infrared protocol<br />

- Can be used with or without bracket, depending<br />

on luminaire type<br />

- Available as option for many luminaires<br />

LRI1340<br />

Occulux<br />

- Mounting height: approx. 3 m<br />

- Default setting light level: 500 - 600 lux<br />

- Easy manual adjustment of minimum light level<br />

during absence<br />

- Movement detection area 20 m 2<br />

- Master-slave installation: up to 7 HFR luminaires<br />

can be slaved to 1 luminaire equipped with<br />

Occulux provided they all remain in the movement<br />

detection area<br />

- Can be used with or without bracket, depending<br />

on luminaire type<br />

- Available as option for many luminaires<br />

LRL1220<br />

Luxsense<br />

- Mounting height: 2-4 m<br />

- Default setting light level: 500 - 600 lux<br />

- Easy manual adjustment of required light level<br />

IRT8099<br />

Commissioning tool for Omnisense luminaires.<br />

Easy to use and inexpensive tool to adjust light<br />

levels and to switch between functionality modes.<br />

Batteries are included.<br />

Product ID European Order<br />

Code (EOC)<br />

IRT8099/00 51889300<br />

~LIGHTM~Lightmaster


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.9<br />

<strong>Lighting</strong> <strong>controls</strong><br />

LIGHTING CONTROLS 11.9


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.10<br />

<strong>Lighting</strong> <strong>controls</strong> Occuswitch<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRM1050/00 SENSR MOV DET ST 0.26 51725400<br />

LRM1051/00 SENSR MOV DET PLUG 0.34 51732200<br />

LRM1060/00 SENSR MOV DET ST IR 0.26 51734600<br />

LRM1061/00 SENSR MOV DET PLUG IR 0.34 51736000<br />

11.10 LIGHTING CONTROLS<br />

Dimensions in mm<br />

~HELIO~Helio lighting management system<br />

LRM1050/00<br />

Movement detector with built-in lighting switch.The<br />

unit is designed for the automatic switching of<br />

lighting in indoor applications. Connection: Screw<br />

terminals. Switch-off delay time from 1 to 35 min.<br />

(selectable).The pattern of sensitivity is nearly<br />

circular; covering an area with a diameter of about<br />

7m.Mounting height 2.5 to 3 m. Daylight-override<br />

10 to 1000 lux (selectable), factory set at 750 lux.<br />

Max. switching current 10 A rms (any load).<br />

LRM1051/00<br />

Movement detector with built-in lighting switch.The<br />

unit is designed for the automatic switching of<br />

lighting in indoor applications. Connection: Wieland<br />

connectors GST 18-3 male/female. Switch-off delay<br />

time from 1 to 35 min. (selectable).The pattern of<br />

sensitivity is nearly circular; covering an area with a<br />

diameter of about 7 m. Mounting height 2.5 to 3 m.<br />

Daylight-override 10 to 1000 lux (selectable), factory<br />

set at 750 lux. Max. switching current 10 A rms (any<br />

load).<br />

LRM1060/00<br />

Movement detector with built-in lighting switch and an<br />

infrared receiver, enabling manual control<br />

(OVERRIDE).The unit is designed for the automatic<br />

switching of lighting in indoor applications. Connection:<br />

Screw terminals. Switch-off delay time from 1 to<br />

35 min. (selectable).The pattern of sensitivity is nearly<br />

circular; covering an area with a diameter of about<br />

7m.Mounting height 2.5 to 3 m. Daylight-override<br />

10 to 1000 lux (selectable), factory set at 750 lux.<br />

Max. switching current 10 A rms (any load).<br />

LRM1061/00<br />

Movement detector with built-in lighting switch and<br />

an infrared receiver, enabling manual control<br />

(OVERRIDE).The unit is designed for the automatic<br />

switching of lighting in indoor applications.<br />

Connection: Wieland connectors GST 18-3<br />

male/female. Switch-off delay time from 1 to 35 min.<br />

(selectable).The pattern of sensitivity is nearly<br />

circular; covering an area with a diameter of about<br />

7m.Mounting height 2.5 to 3 m. Daylight-override<br />

10 to 1000 lux (selectable), factory set at 750 lux.<br />

Max. switching current 10 A rms (any load).


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.11<br />

<strong>Lighting</strong> <strong>controls</strong> Occuswitch<br />

ASSOCIATED PRODUCTS<br />

Dimensions in mm<br />

IRT8010/00 LRH8010/00<br />

IRT8050/00<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRM1064/00 SENSR ABS DET ST IR 0.26 51755100<br />

LRM1065/00 SENSR ABS DET PLUG IR 0.34 51757500<br />

IRT8010/00 TRANSM IR POINT 0.06 51749000<br />

LRH8010/00 MOUNT IR POINT 0.03 51797100<br />

IRT8050/00 TRANSM IR 2KEY WALL 0.12 51707000<br />

LRM1064/00<br />

Movement detector with built-in lighting switch and<br />

an infrared receiver, enabling manual control<br />

(MANUAL SWITCH ON).The unit is designed for<br />

the automatic switching of lighting in indoor<br />

applications. Connection: Screw terminals. Switch-off<br />

delay time from 1 to 35 min. (selectable).The<br />

pattern of sensitivity is nearly circular; covering an<br />

area with a diameter of about 7 m. Mounting height<br />

2.5 to 3 m. Daylight-override 10 to 1000 lux<br />

(selectable), factory set at 750 lux. Max. switching<br />

current 10 A rms (any load).<br />

LRM1065/00<br />

Movement detector with built-in lighting switch and<br />

an infrared receiver, enabling manual control<br />

(MANUAL SWITCH ON).The unit is designed for<br />

the automatic switching of lighting in indoor<br />

applications. Connection: Wieland connectors<br />

GST 18-3 male/female. Switch-off delay time from<br />

1 to 35 min. (selectable).The pattern of sensitivity is<br />

nearly circular; covering an area with a diameter of<br />

about 7 m. Mounting height 2.5 to 3 m. Daylightoverride<br />

10 to 1000 lux (selectable), factory set at<br />

750 lux. Max. switching current 10 A rms (any load).<br />

LIGHTING CONTROLS 11.11


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.12


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.13<br />

<strong>Lighting</strong> management<br />

The working environment<br />

People think and work better in a comfortable environment, which<br />

leads to better productivity.Today's office buildings need to be<br />

adaptable to the needs of both individual users and the companies<br />

they work for.A networked lighting management system is an<br />

essential part of a modern lighting installation.<br />

Flexibility<br />

Change - in a modern building this can happen every day. Philips'<br />

lighting management systems have been developed with change in<br />

mind. From the easily installed hardware to the user-friendly local<br />

override facilities these solutions make change much easier to deal<br />

with, while still delivering the individual lighting levels chosen by the<br />

staff.<br />

LIGHTING CONTROLS 11.13


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.14<br />

LightMaster<br />

LightMaster – Networked lighting management<br />

LightMaster is a family of networked lighting <strong>controls</strong>, which are very<br />

attractive to budget-conscious users, designers and installers.<br />

LightMaster components are built into a simple, yet highly flexible<br />

networked lighting control and monitoring system, that also offers<br />

simple and effective integration possibilities.<br />

With building use changing regularly, often within months, the<br />

expense of reconfiguration is now an important factor for every<br />

building operator.This system is specifically designed to facilitate any<br />

required changes in the lighting installation through the powerful yet<br />

easy-to-use LightManager software suite. Monitoring facilities range<br />

from simple status indication to sophisticated event and run-time<br />

logging.<br />

1. Intial configuration<br />

11.14 LIGHTING CONTROLS<br />

9-output LCM, switching<br />

and dimming<br />

Luminaire<br />

2. Changed configuration (lay-out)Caption<br />

User-friendly graphics<br />

LightManager is both the configuration tool and the user interface<br />

for LightMaster.The package is specifically designed to run under<br />

Microsoft Windows, ensuring that it has a familiar ‘look and feel’ to<br />

welcome the user. Building plans and lighting layouts are imported<br />

from AutoCAD or other industry-standard design packages.These<br />

files then become the foundation of the lighting control system’s<br />

supervisory software. Easily understood icons that give absolute<br />

clarity to the facilities management team illustrate all the lighting<br />

system components.<br />

Multi-sensor<br />

Wall switch


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.15<br />

Helio<br />

Helio - Innovation by integration<br />

Helio is a lighting control system for building-wide control, which can<br />

become an integral part of the building management concept using<br />

one network. Its open system architecture, open communications<br />

protocol and standardised technology allow Helio to be easily<br />

integrated with systems supplied by different vendors such as<br />

heating, ventilation, window blinds, building access and more.<br />

2-output LCM<br />

8-output LCM, either switching<br />

only or switching and dimming<br />

Luminaire<br />

LON multi-sensor or<br />

conventional<br />

(multi-) sensor<br />

1. Get ready for integration<br />

InfraRed receiver<br />

Heating & ventilation<br />

controller<br />

Sunblind controller<br />

2. Take control with sensors,<br />

transmitters and pushbuttons<br />

Integration on all levels<br />

Helio is based on Echelon’s LonWorks® technology, the de facto<br />

standard for leading suppliers of building services <strong>controls</strong>. Plug-ins<br />

for other tools, such as LonMaker for Windows®, are also provided.<br />

As a result Helio offers numerous solutions for lighting and<br />

integration, driven by users’ demands for investment benefits,<br />

functionality and upgradeability.Three levels of lighting solutions give<br />

you virtually unlimited possibilities.These range from a<br />

basic solution for centralised lighting control, through<br />

a system with more advanced control functions using<br />

sensors, transmitters and pushbuttons, to a fully<br />

integrated approach to building <strong>controls</strong>.<br />

3. Complete integration<br />

with HVAC systems and sunblinds<br />

LIGHTING CONTROLS 11.15


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.16<br />

<strong>Lighting</strong> <strong>controls</strong> Lightmaster<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LBC5000/00 SOFTW A62PC+SOFTW 4.00 53552400<br />

LBC5001/02 SOFTW CARD+SOFTW 0.15 53734400<br />

LFC5255/00 NETWK AREA CONTR 2.44 53932400<br />

11.16 LIGHTING CONTROLS<br />

Dimensions in mm<br />

LRH5300/50 CONTR BASE ASSY PLUG 1.26 53422000<br />

LLC5319/50 CONTR 9X4 PLUG SW&RE 1.71 53460200<br />

LLC5319/70 CONTR 9X4 PLUG SW&RE D-NO 1.00 53710800<br />

LLC5319/71 CONTR 9X4 PLUG SW&RE D-LIM 1.80 53762700<br />

LLC5359/50 CONTR 9X4 PLUG SW&RE RC5 1.71 53930000<br />

~LIGHTM~Lightmaster<br />

LBC5000/00<br />

Central Supervisor. IBM compatible PC with<br />

software and interface card, user interface to the<br />

LM100 system. A Central Supervisor can control up<br />

to 60 Area Controllers.<br />

Also available:<br />

LBC5001/02 Interface Card and LightManager<br />

Software to be used with a PC provided by the<br />

client.<br />

LFC5255/00<br />

Area Controller. A building controlled by a LM100<br />

system is split into a number of areas. Each area is<br />

supervised with an Area Controller.The Area<br />

Controller manages network traffic, schedules time<br />

commands and implements re-configuration<br />

commands from the Central Supervisor.<br />

LRH5300/50<br />

Base to be used with LLC5319 <strong>Lighting</strong> Control<br />

Modules.<br />

LLC5319<br />

Pluggable <strong>Lighting</strong> Control Module with 4 inputs and<br />

9 outputs (Wieland GST). Each output can be<br />

configured to control any light or combination of<br />

lights anywhere on the system. Each individual<br />

output is allowed to switch up to 4 A, with a<br />

maximum for all outputs up to 10 A divided over<br />

the two sides, each 5 A. Requires the LRH5300/50<br />

base to be mounted on.<br />

Versions available:<br />

LLC5319/50 Pluggable LCM (1-10V).<br />

LLC5319/70 Pluggable LCM for use with DALI<br />

ballasts (no feedback).<br />

LLC5319/71 Pluggable LCM for use with DALI<br />

ballasts (limited feedback).<br />

LLC5359/50 Pluggable LCM (1-10V) for use with<br />

RC5 IR remote control.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.17<br />

<strong>Lighting</strong> <strong>controls</strong> Lightmaster<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LLC5314/50 CONTR 4X4 ST SW&RE 0.89 53572200<br />

LRH5304/50 CONTR BASE ASSY ST 2.14 53590600<br />

LLC5702/50 CONTR 2X2 GT SW&RE 0.36 53574600<br />

LLC5702/41 CONTR 2X2 GT SW&RE TIN 1.37 53412100<br />

LLC5702/42 CONTR 2X2 GT SW&RE 2TIN 1.72 53413800<br />

LLC5702/72 CONTR 16X2 GT SW&RE D 0.40 53756600<br />

LLC5702/73 CONTR 16X2 GT SW&RE IN 1.37 53758000<br />

LLC5314/50<br />

<strong>Lighting</strong> Control Module with screw terminals for<br />

4 inputs and 4 outputs (1-10 V).This unit is used to<br />

control circuits of lights. Each input can be<br />

configured to control any light or combination of<br />

lights anywhere on the system. Requires the<br />

LRH5304/50 Base to be mounted on. Dimension<br />

drawing includes the base (LRH5304/50).<br />

LRH5304/50<br />

Base to be used with LLC5314/50 <strong>Lighting</strong> Control<br />

Module. Dimension drawing includes the lighting<br />

control module (LCC5314/50).<br />

LLC5702/50<br />

Separate Gear Tray <strong>Lighting</strong> Control Module. Can be<br />

mounted inside a luminaire or switch cabinet.<br />

1-10V analogue dimming.<br />

LLC5702/72 Gear Tray <strong>Lighting</strong> Control Module,<br />

with single DALI output, 16 addresses and feedback,<br />

2 inputs.<br />

LLC5702<br />

Gear Tray <strong>Lighting</strong> Control Module with terminals<br />

for 2 outputs and 2 inputs in metal enclosure. Each<br />

input can be configured to control any light or<br />

combination of lights anywhere on the system.<br />

Versions available:<br />

LLC5702/41 1 Gear Tray <strong>Lighting</strong> Control Module in<br />

metal enclosure.<br />

LLC5702/42 2 Gear Tray <strong>Lighting</strong> Control Modules<br />

in 1 metal enclosure.<br />

LLC5702/73 1 Gear Tray <strong>Lighting</strong> Control Module in<br />

metal enclosure with one DALI output, 16 addresses<br />

and feedback, 2 inputs.<br />

LIGHTING CONTROLS 11.17


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.18<br />

<strong>Lighting</strong> <strong>controls</strong> Lightmaster<br />

11.18 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LLC5714/00 CONTR 0X4 DIN 0.28 53414500<br />

LLC5714/41 CONTR 0X4 DIN TIN 1.70 53416900<br />

LLC5724/50 CONTR 4X0 DIN SW&RE 0.47 53578400<br />

LLC5724/41 CONTR 4X0 DIN SW&RE TIN 1.84 53417600<br />

LLC5714/00<br />

Input Module for DIN Rail mounting.<br />

LLC5714/41<br />

Input Module with 4 inputs in metal enclosure.<br />

Allows the connection of 4 sensors or switches.<br />

Each sensor or switch can be configured to control<br />

any light or combination of lights anywhere on the<br />

system.<br />

LLC5724/50<br />

Output Module for DIN Rail mounting.<br />

LLC5724/41<br />

Output Module with 4 outputs in metal enclosure.<br />

It has screw terminals for 4 light circuits. Each of the<br />

outputs can be addressed individually.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.19<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRC5040/10 CONTR 1x1 ST SW&RE 0.47 51625700<br />

LRC5042/00 CONTR 2x1 ST SW&RE 1.10 51727800<br />

LRC5043/00 CONTR 2x2 ST SW&RE 1.20 53708500<br />

LRC5038/10 CONTR 8x4 PLUG S 1.48 53740500<br />

~HELIO~Helio lighting management system<br />

LRC5040/10<br />

Helio light controller with single channel for<br />

switching and regulating lighting loads up to 5 A, and<br />

providing a sensor interface for standard IR<br />

receivers, pushbutton interface units, movement<br />

detectors, and light sensors.<br />

LRC5042/00<br />

Helio light controller with two separately controlled<br />

outputs and one interface for standard movement,<br />

light and infrared sensors.The outputs are able to<br />

switch and regulate lighting loads up to 5 A.The<br />

outputs and LON bus have screw connections, the<br />

sensor interface is connected via RJ12 plug.<br />

LRC5043/00<br />

Helio light controller identical to the LRC5042 but<br />

with two sensor interfaces for standard movement<br />

detectors, lights sensor and IR receiver and two<br />

inputs for standard wall switches.The outputs have a<br />

6-pole screw conector that provides Live, Neutral,<br />

Protective Earth, Maintained live for power supply to<br />

batteries in emergency luminaires and a + and - for<br />

1- 10 V dimming.<br />

LRC5038/10<br />

Helio light controller with eight switchable outputs,<br />

two pairs of sensor interfaces for standard<br />

movement detectors, light sensors, IR receivers and<br />

two inputs for standard wall switches.The outputs<br />

are able to switch lighting loads up to 4 A.The unit<br />

has a maximum total rating of 10 A divided over the<br />

two sides, each 5 A. Each output has a 3-pole<br />

Wieland socket (GST) that provides Live, Neutral<br />

and Protective Earth.<br />

LIGHTING CONTROLS 11.19


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.20<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRC5048/00 CONTR 8x4 PLUG SW&RE 3.00 51688200<br />

LRI5133/10 SENSR LON MULTISENSOR 0.30 51684400<br />

11.20 LIGHTING CONTROLS<br />

Dimensions in mm<br />

LRC5048/00<br />

Helio light controller with eight separately controlled<br />

outputs and two interfaces for standard movement<br />

detectors, light sensors and pushbutton switches.The<br />

outputs are able to switch and regulate lighting loads<br />

up to 5 A.The unit has a maximum total rating of<br />

16 A. Each output has a 6-pole Wieland socket<br />

(GST) that includes a maintained live for power<br />

supply to batteries in emergency luminaires. Battery<br />

performance can then be tested by interrupting the<br />

maintained power supply at prescribed intervals.<br />

LRI5133/10<br />

Helio multi-sensor with movement detector, light<br />

sensor, and infrared receiver used for remote and<br />

automatic control of lighting, HVAC and sun blind<br />

functions in integrated room control applications.The<br />

IR receiver can be combined with hand-held and wall<br />

transmitters for remote control operations and with<br />

wall transmitters with built-in temperature sensors for<br />

automatic temperature control. Units are connected<br />

directly to LonWorks ® bus cable for network<br />

communication and power supply.Their functional<br />

behaviour can adapted by downloading project<br />

specific software over the bus.<br />

Mounting plate for surface mounting of LRI5133.<br />

This plate is packed together with the sensor itself.<br />

Mounting ring for recessed mounting of LRI5133.<br />

This ring is packed together with the sensor itself.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.21<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LCU5305/00 NETWK 2x2 DIG I/O 0.20 51614100<br />

LCU5315/20 NETWK CLOCK 0.20 51615800<br />

LCN5225/00 NETWK POWER 0.60 51611000<br />

LCN5235/00 NETWK REPEATER 0.60 51612700<br />

LCU5305/00<br />

Helio digital I/O module providing a simple dry<br />

contact interface to and from various systems.<br />

The unit has 2 inputs and 2 outputs.<br />

LCU5315/20<br />

Helio system clock providing a real time clock and<br />

programmable switching schedule.<br />

LCN5225/00<br />

Helio bus power supply unit providing a voltage of<br />

42 V DC and a current of 1.4 A to the linkpower<br />

bus.The bus voltage and current is used by devices<br />

using LPT transceivers like Helio sensors, system<br />

clocks and digital I/Os.<br />

LCN5235/00<br />

Helio bus power supply/repeater regenerating bus<br />

communication and providing power to the bus.<br />

LIGHTING CONTROLS 11.21


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.22<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LCN5245/00 NETWK ROUTER 0.60 51613400<br />

LCC5301/00 CABLE BUS 100M 0.01 51714800<br />

LCS5425/00 SOFTW UNILON CLIENT 0.10 51758200<br />

LCS5430/00 SOFTW UNILON SERVER 0.60 51756800<br />

LCS5435/00 SOFTW UNILON TRAIN 0.60 51849700<br />

LCS5495/00 SOFTW UNILON CREDIT - 51759900<br />

11.22 LIGHTING CONTROLS<br />

Dimensions in mm<br />

LCN5245/00<br />

Helio bus power supply/router repeater<br />

regenerating and managing bus communication and<br />

providing power to the bus.<br />

LCC5301/00<br />

<strong>Lighting</strong> control busline, used to interconnect all<br />

system components of the Helio lighting<br />

management system.<br />

The busline carries all data exchange between the<br />

various "modules" of Helio.<br />

The LCC5301 is a cable of 100 m without<br />

connectors.<br />

Unilon software.<br />

Unilon is a general configuration tool for<br />

LonWorks ® based systems. It offers a fully graphical<br />

user interface and many other features for<br />

commissioning of LonWorks ® systems. Each actual<br />

installation of one node in a network requires a<br />

license, so-called credit key. Unilon is now available in<br />

client and server version. Credits can be separately<br />

ordered in variable amounts.The server package<br />

includes documentation files about Helio and<br />

Unilon.<br />

Helio LNS Plug-ins.<br />

Plug-ins for other configuration tools like<br />

LonMaker for Windows are also available. For<br />

more information please contact your local Philips<br />

<strong>Lighting</strong> Controls representative.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.23<br />

<strong>Lighting</strong> <strong>controls</strong><br />

LIGHTING CONTROLS 11.23


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.24


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.25<br />

Architecture and shops<br />

Versatile control range<br />

Scenio100 / MultiDim is a scene setting lighting control range that<br />

cover a wide range of applications. It provides from simple to<br />

comprehensive control facilities at the touch of a button.With an<br />

easy-to-use remote control different preset scenes can be<br />

programmed and selected, changing the mood of the room in<br />

seconds.<br />

Creative lighting design<br />

With its capacity to control a large number of channels of lighting,<br />

the Scenio100 / MultiDim range is ideally suited for applications using<br />

many different types of luminaries for incandescent, halogen and<br />

fluorescent lamps. In addition Scenio100 / MultiDim can also be used<br />

to switch on projectors, lower projection screens or close window<br />

blinds at just the touch of a button.<br />

Scene setting for all occasions<br />

The Scenio100 / MultiDim product range can be applied in situations<br />

such as conference halls, boardrooms, lecture theatres, hotel<br />

functions rooms, museums, showrooms, cafes, restaurants and shops.<br />

Caption<br />

Shoebaloo, Amsterdam<br />

Colours set the mood and add emotion<br />

LIGHTING CONTROLS 11.25


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.26<br />

MultiDim<br />

Digital control solution<br />

Philips DALI MultiDim offers today’s most versatile and easy-toinstall<br />

solution that brings the benefits of digital lighting control to<br />

many different application areas.Whether in shops, offices,<br />

conference rooms, hotels, restaurants or other applications.<br />

Quick and economic installation<br />

MultiDim consists of an integrated range of DALI-compatible devices<br />

that can be combined flexibly to create exactly the desired control<br />

functions.The systems addressable digital architecture means that<br />

only a single two-core cable is needed to interconnect all units.The<br />

possibility to eliminate conventional vertical wall wiring both reduces<br />

installation time and cost, and greatly increases the ease with which<br />

later changes can be implemented.<br />

MultiDim product range<br />

11.26 LIGHTING CONTROLS<br />

Freedom in lighting design<br />

MultiDim offers unbeatable freedom and ease of lighting system<br />

design.The MultiDim controllers can be used in combination with<br />

DALI-compatible fluorescent lamp ballasts and lamp interface units<br />

(both high voltage incandescent lamps and low voltage halogen<br />

lamps).Where necessary control functions can be provided by adding<br />

the required MultiDim units such as dimmers, control panels, IR<br />

remote control units and multi sensors for light levels and room<br />

occupancy.<br />

Maximising flexibility with DALI<br />

Thanks to the systems digital addressable control and<br />

communication concept, each unit in the DALI network has its own<br />

unique address that allows it to be switched and controlled<br />

independently.The systems single control line can be used to control<br />

different groups of lamps, and up to 63 devices connected to the<br />

same physical control wire can be addressed and controlled<br />

independently.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.27<br />

Scenio100<br />

Powerful control solution<br />

Scenio100 enables the lighting designer to achieve the correct<br />

ambience for all occasions. Either simple or advanced effects may be<br />

set at the touch of a button, including dynamic lighting and colour<br />

change as well as daylight linking and time control options. Scenes<br />

are created via software run on a PC, LCD touch screen or by<br />

infrared hand held transmitter.<br />

Flexibility in applications<br />

In retail areas time sequenced scene and colour changing is used to<br />

stimulate sales by highlighting products and creating an exciting<br />

environment. In restaurants Scenio100 provides the right atmosphere<br />

for a light breakfast, a working lunch or an intimate dinner.<br />

Other indoor applications include: museums, exhibition and<br />

conference centres, lecture theatres, leisure centres, stadiums, hotels,<br />

public buildings and prestige homes. Scenio100 is also highly effective<br />

in outdoor applications, particularly floodlighting.<br />

Choice of Dimming Racks<br />

Tungsten, low voltage, LED, cold cathode, fluorescent and all other<br />

dimmable light sources may be controlled using phase cutting, digital<br />

or DC voltage techniques. Dimming modules are built into compact,<br />

standard or custom-built racks, which are connected by a serial data<br />

bus to create a multi-channel control solution. Racks feature a mains<br />

input isolator and circuit breakers for individual output protection, as<br />

well as inputs for serial and DMX control, and voltage free contacts<br />

providing an interface to other building management systems.<br />

Control Interfaces<br />

Scenes can be controlled by LCD touch screen, infrared remote<br />

control and manual button control plate. Control plates with a satin<br />

anodised aluminium finish are standard available, with other<br />

decorative finishes optional available. Partition switches join and<br />

separate the control of rooms with demountable partitions.<br />

For further information about the versatile<br />

Scenio 100 system, please contact your local<br />

Philips <strong>Lighting</strong> representative.<br />

LIGHTING CONTROLS 11.27


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.28<br />

Industry lighting systems - Linesense<br />

<strong>Lighting</strong> <strong>controls</strong> in industry<br />

Industrial buildings today are<br />

models of efficiency in meeting<br />

their specific purpose – be it a<br />

logistics’ warehouse or a major<br />

manufacturing complex. <strong>Lighting</strong> in<br />

these environments plays the<br />

same important role as it does in<br />

any other work place.<br />

Philips industrial lighting control<br />

solutions are specifically intended<br />

to meet the exacting demands of<br />

these buildings to be both cost<br />

effective and well lit facilities.<br />

<strong>Lighting</strong> <strong>controls</strong> for TTX400 light-lines<br />

Today’s warehouses and distribution centres can be characterised by<br />

their large size and the few people employed. Light is switched on all<br />

day although the employees need it only for a limited time. For those<br />

applications Philips <strong>Lighting</strong> offers a stand-alone control solution,<br />

Linesense, to be used in combination with TTX400 light-lines.<br />

Linesense dims or even switches off the lights when nobody is<br />

present in a particular zone.<br />

Linesense extention with movement detector<br />

11.28 LIGHTING CONTROLS<br />

Easy to install<br />

The Linesense range comprises a supplementary 300 mm trunking<br />

element, containing the controller, for addition to the TTX400 light<br />

line.This extra unit is easily installed between the light line and the<br />

electrical connection unit – the “6th click” in the TTX400 system.<br />

High bay movement detectors and, optionally, a light sensor are<br />

simply connected through RJ-12 modular cables to the dedicated<br />

brackets. Once installed, the system works automatically and requires<br />

no extra maintenance.<br />

Energy saving<br />

Linesense, in combination with the highly efficient TTX400<br />

luminaires, decreases energy costs substantially by using presence<br />

detection, daylight linking and manual control.<br />

Examples show that energy savings up to 75% can be achieved.With<br />

Linesense energy savings are realised from day one, with no<br />

additional costs in the long run.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.29<br />

LON-DALI<br />

Digital intelligence for Light-lines<br />

The LON-DALI control system provides optimal lighting where it’s<br />

needed and when it’s needed. Promoting maximum productivity,<br />

comfort and safety.A system, moreover, that’s simple to operate and<br />

to adapt to changing industrial requirements. Providing a unique<br />

solution that truly reflects the needs of modern industry – today and<br />

into the future.<br />

Adaptive to needs and activities<br />

The LON-DALI system allows creating lighting zones within and<br />

across light-lines (TTX400 and Maxos). It offers total flexibility to<br />

control the lighting behaviour of each zone and even to reprogram<br />

the zones into a new lighting arrangement to accommodate changes<br />

in floor layout or production activity. New arrangements can be<br />

software configured with no need for rewiring.<br />

Caption<br />

LON-DALI system solution<br />

Optimal lighting<br />

The system, moreover, accommodates time control, manual control,<br />

movement detection and daylight regulation – resulting in optimal<br />

illumination of all tasks on the factory floor and increasing operator<br />

productivity, efficiency, comfort and safety.<br />

Taking control<br />

The LON-DALI controller allows for status monitoring including<br />

individual lamp and ballast status, burning hours and energy<br />

consumption in each light zone. Ensuring that the light line<br />

installation always functions at optimum efficiency, and allowing for<br />

accurate cost allocation to individual departments using the<br />

installation.The controller provides the means to have this<br />

information to be integrated into a modern Building Management<br />

System.<br />

LRC5140/41- LON-DALI light controller for industry<br />

LIGHTING CONTROLS 11.29


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.30<br />

<strong>Lighting</strong> <strong>controls</strong> Trios system<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRC1010/10 CONTR 1x1 ST S 0.46 51643100<br />

LRC1020/10 CONTR 1x1 ST SW&RE 0.46 51645500<br />

LRC1030/00 CONTR 1x1 PROG ST SW&RE 0.46 51583000<br />

LRC1015/10 CONTR 1x1 DIN S 0.33 51644800<br />

LRC1025/10 CONTR 1x1 DIN SW&RE 0.33 51646200<br />

LRC1035/00 CONTR 1x1 PROG DIN SW&RE 0.33 51586100<br />

11.30 LIGHTING CONTROLS<br />

Dimensions in mm<br />

~HELIO~Helio lighting management system<br />

LRC1010/10<br />

LRC1020/10<br />

LRC1030/00<br />

Trios multifunctional and addressable light controllers<br />

in a housing for distributed installation in three<br />

versions.The switching (LRC1010) and the<br />

switching/regulating (LRC1020) versions have<br />

pre-defined functionalities that depend on the<br />

connection of movement detector, infrared receiver<br />

and/or light sensor.They are specifically designed for<br />

energy saving solutions with dimmable and<br />

non-dimmable luminaires.The functionality of the<br />

switching and regulating LRC1030 can be adapted<br />

by PC programming software (available separately)<br />

for special lighting control applications. A highly<br />

informative Trios Manual is available to assist<br />

designers and installers in selecting the correct<br />

products for their applications.<br />

LRC1015/10<br />

LRC1025/10<br />

LRC1035/00<br />

Trios multifunctional and addressable light controllers<br />

in a DIN-rail housing for centralised installation in<br />

three versions.The switching (LRC1015) and the<br />

switching/regulating (LRC1025) versions have<br />

pre-defined functionalities that depend on the<br />

connection of a movement detector, infrared<br />

receiver and/or light sensor.They are specifically<br />

designed for energy saving solutions with dimmable<br />

and non-dimmable luminaires.The functionality of<br />

the switching and regulating LRC1035 can be<br />

adapted by PC programming software (available<br />

separately) for special lighting control applications.<br />

A highly informative Trios Manual is available to assist<br />

designers and installers in selecting the correct<br />

products for their applications.<br />

LCS1030/00<br />

Trios Software<br />

Software for use on a PC to alter the parameters of<br />

the LRC1030/1035 controllers.<br />

Trios Handbook<br />

Trios Handbook, intended to assist consultants,<br />

engineers, installers and other professionals involved<br />

in project management and design, and in specifying<br />

and procuring lighting control systems. Its purpose is<br />

to aid the reader in selecting the most effective<br />

lighting solution for a particular application<br />

requirement. It describes the fundamental<br />

technicalities of the Trios system and its associated<br />

components, and gives detailed information on<br />

installation, test and commissioning.<br />

More information: www.<strong>controls</strong>4lighting.com


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.31<br />

<strong>Lighting</strong> <strong>controls</strong> Scenio system<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

LRC1555/00 CONTR 1X1 0.35 51653000<br />

LRC1505/00 CONTR 1X0 EXTENSION 0.35 51651600<br />

IRT8020/00 TRANSM IR SCENIO 0.22 51761200<br />

~TRIOS~Trios system<br />

LRC1555/00<br />

Scenio light controller with two modular sockets:<br />

one dedicated for sensors (IR receivers and/or<br />

movement detectors) and the other for businterconnection<br />

to the extension modules LRC1505.<br />

Up to three IR receivers and three movement<br />

detectors can be connected to the sensor input.<br />

The unit has one output channel suitable to switch a<br />

maximum load of 1150 VA, and a 1-10 V DC<br />

regulation output.<br />

LRC1505/00<br />

Scenio extension module to be linked to the light<br />

controller LRC1555 via a communication bus line. It<br />

has two modular sockets, both intended for bus<br />

loop-through connections. Sensors (IR receivers,<br />

movement detectors) cannot be connected to this<br />

unit.The unit has one output channel suitable to<br />

switch a maximum load of 1150 VA, and a 1-10 V<br />

DC regulating output. A 20 cm busline<br />

interconnection cable is supplied with the unit.<br />

IRT8020/00<br />

Eight-preset hand-held transmitter, suitable for<br />

infrared control of Scenio applications. It has 4 keys<br />

for presets and one key for “all off”. Keys for<br />

individual control and preset programming are<br />

located under a hinged cover at the bottom of the<br />

transmitter. In “teach mode” the transmitter can be<br />

used as a commissioning tool for Scenio.The group<br />

address selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

wall holder and batteries.<br />

LIGHTING CONTROLS 11.31


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.32<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

11.32 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

IRT8010/00 TRANSM IR POINT 0.06 51749000<br />

LRH8010/00 MOUNT IR POINT 0.03 51797100<br />

IRT8050/00 TRANSM IR 2KEY WALL 0.12 51707000<br />

IRT8030/00 TRANSM IR TRIOS 0.22 51763600<br />

~GENERAL~General purpose components<br />

IRT8010/00<br />

Hand-held two-key transmitter, for infrared control of<br />

various lighting control systems.This transmitter was<br />

developed for the Occuswitch “presence” and<br />

“absence”, but it can also be used with Trios and<br />

other systems.The Occuswitch-IR is only able to<br />

switch, but when the transmitter is used with the<br />

named systems it can also dim the lights (by pressing<br />

a button >0.5 sec).The group address selector switch<br />

is contained in the battery compartment.The unit is<br />

supplied with batteries. A wall holder is available.<br />

LRH8010/00<br />

Wall holder for the IRT8010 hand-held two-key<br />

transmitter.<br />

IRT8050/00<br />

Two-key infrared remote control transmitter for wall<br />

mounting and table-top use.The unit can be used in<br />

Trios applications.The actual function of the two<br />

large keys can be selected with a dip switch in the<br />

battery compartment. A dip switch is also used to<br />

select the group address.<br />

IRT8030/00<br />

Four-preset hand-held transmitter, suitable for<br />

infrared control of Trios applications. It has 4 keys for<br />

presets and one key for “all off”. Keys for individual<br />

control and preset programming are located under a<br />

hinged cover at the bottom of the transmitter. In<br />

“teach mode” the transmitter can be used as<br />

commissioning tool for Trios.The group address<br />

selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

wall holder and batteries.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.33<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

IRT8040/00 TRANSM IR SYS 0.22 51765000<br />

IRT8080/00 TRANSM IR MULTI-FUNC 0.22 51767400<br />

IRT8055/00 TRANSM IR 2KEY WALL TEMP 0.12 51843500<br />

IRT8040/00<br />

Hand-held transmitter, suitable for infrared control of<br />

Helio applications combined with HVAC and<br />

Sunblind systems. It has keys for two lighting groups,<br />

blinds control and temperature control and a key for<br />

“all off/absence”. Keys for lighting presets and preset<br />

programming are located under a hinged cover at<br />

the bottom of the transmitter.The group address<br />

selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

wall holder and batteries.<br />

IRT8080/00<br />

Hand-held transmitter, suitable for infrared control of<br />

various lighting control systems, other building<br />

systems (sunblind, HVAC).The transmitter can easily<br />

be adapted to project specifications by selecting one<br />

of its 15 settings.This can be achieved without any<br />

tools, and even after installation.The group address<br />

selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

text plates for the various settings, wall holder and<br />

batteries.<br />

IRT8055/00<br />

Multi-purpose infrared remote control transmitter<br />

for wall mounting, suitable for the transmission of<br />

measured temperature values.The unit can be used<br />

in integrated control systems with Heating,<br />

Ventilation and Airconditioning (HVAC) in<br />

combination with Helio applications.The actual<br />

function of the two large keys can be selected with<br />

a switch in the battery compartment.The same<br />

switch is used to select the group address. Only<br />

available as project special.<br />

LIGHTING CONTROLS 11.33


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.34<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

11.34 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

LRM8114/00 SENSOR MOV DET 0.07 51906700<br />

LRI8134/00 SENSOR MULTISENSOR 0.07 51904300<br />

LRM8115/00 SENSR MOV DET LONG 0.07 51722300<br />

LRM8116/00 SENSR MOV DET WIDE 0.07 51841100<br />

LRM8114/00<br />

Compact advanced movement detector that<br />

features variable delay-to-off via DIP switch and can<br />

be part shaded to limit coverage.The sensor is<br />

powered via the additional modular plug-in (RJ12)<br />

connector cable that attaches it to a lighting<br />

controller.The sensor is suitable for both recessed<br />

and surface mounting. Mounting height is between<br />

2.5 m and 3.5 m.<br />

LRI8134/00<br />

Compact multi-sensor combining advanced internal<br />

light sensor, movement detector and infra-red<br />

receiver.The unit features individual element<br />

selection, variable delay-to-off via DIP switch and<br />

auto-calibrating light sensor. Movement detector can<br />

be part shaded to limit coverage.The sensor is<br />

powered via the additional modular plug-in (RJ12)<br />

connector cable that attaches it to a lighting<br />

controller.The sensor is suitable for both recessed<br />

and surface mounting. Mounting height is between<br />

2.5 m and 3.5 m.<br />

LRM8115/00<br />

Wall-mounted passive infrared movement detector<br />

for energy saving solutions in indoor lighting<br />

applications (automatic light switching based on<br />

occupancy). It detects the slightest movement within<br />

a range 25 m long. Equipped with adjustable<br />

switchoff delay times up to 35 minutes. Electrical<br />

connections via an additional sensor cable with a<br />

modular socket (“snap-in”).The daylight override<br />

function prevents the lights being witched on, if<br />

enough daylight is available.<br />

LRM8116/00<br />

Wall-mounted passive infrared movement detector<br />

for energy saving solutions in indoor lighting<br />

applications (automatic light switching based on<br />

occupancy). It detects the slightest movement within<br />

an angle of 90º (maximum range 15 m by 15 m at a<br />

mounting height of 2.1 m). Equipped with adjustable<br />

switchoff delay times up to 35 minutes. Electrical<br />

connections via an additional sensor cable with a<br />

modular socket (“snap-in”).The daylight override<br />

function prevents the lights being switched on, if<br />

enough daylight is available.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.35<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

Product ID<br />

Dimensions in mm<br />

Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

IRR8125/00 SENSR IR NV 0.03 51716200<br />

LRD8000/00 DIMMER 1KVA MAGNETIC TX 0.40 51571700<br />

LRD8010/10 DIMMER 1KVA ELECTRONIC TX 0.53 51573100<br />

LCU8020/00 INTERF PUSHBUTTON 0.10 51656100<br />

IRR8125/00<br />

Infrared receiver for remote control of lighting<br />

systems and other building-related functions.The unit<br />

is especially intended for “invisible” mounting behind<br />

a false ceiling. Only a thin plastic optic protrudes<br />

from the ceiling. More infrared receivers can be<br />

connected in parallel to cover large or odd-shaped<br />

rooms. It is powered from the corresponding<br />

controller, not requiring an external power supply<br />

unit. Electrical connections with a fixed cable (1 m.)<br />

with modular plug. Mounting height 2.5 to 3 m.<br />

LRD8000/00<br />

Light regulator for incandescent lamps, high-voltage<br />

halogen lamps and low-voltage halogen lamps with<br />

conventional transformers.The minimum light output<br />

level can be adjusted between 1% and 10% of<br />

maximum light output level. A green “power on”<br />

LED indicates the power status of the unit. Max. load<br />

is 1000 VA.<br />

LRD8010/10<br />

Light regulator for incandescent lamps, high-voltage<br />

halogen lamps and low-voltage halogen lamps with<br />

electronic transformers.The minimum light output<br />

level can be selected between 1% and 10% of<br />

maximum light output level. A green “power on”<br />

LED indicates the power status of the unit. Max. load<br />

is 1000 VA.<br />

LCU8020/00<br />

Push-button interface. RC5 code generator with<br />

digital inputs for the connection of push-buttons.<br />

Intended for manual control of light controllers and<br />

for coupling to other systems such a building<br />

management systems.The unit is connected to the<br />

infrared remote control input of the controller.<br />

Combination with an IR receiver is possible. Codes<br />

generated, depend on the input terminals used,<br />

20 combinations are possible. Different sets of<br />

codes, for Helio/Trios and Scenio can be selected<br />

with a rotary switch.The unit is powered from the<br />

corresponding controller.<br />

LIGHTING CONTROLS 11.35


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.36<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

11.36 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LPS100/00 POTSW 1-10V DIM 0.14 55803900<br />

LPS100/01 POTSW 1-10V DIM 0.14 55806000<br />

LCC8024/00 CONN BLOCK RJ12 1M-3F 0.01 51599100<br />

LPS100/00<br />

Manual rotary potentiometer with microswitch for<br />

recessed mounting. In combination with one or<br />

more electronic HF lightregulating ballasts, electronic<br />

light regulators or Trios controllers, it serves to<br />

control the light level of fluorescent lamps, halogen<br />

lamps or incandescent lamps.<br />

LPS100/01<br />

Manual rotary potentiometer with microswitch for<br />

surface mounting. In combination with one or more<br />

electronic HF light-regulating ballasts, electronic light<br />

regulators or Trios controllers, it serves to control<br />

the light level of fluorescent lamps, halogen lamps or<br />

incandescent lamps.<br />

LCC8024/00<br />

Branching connector with three modular sockets<br />

and one modular plug for use when more sensors<br />

are to be connected to the same controller input<br />

socket. (Or extension cable socket).


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.37<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

LCC8014/00 CABLE SENSR RJ12M-RJ12M 5M 0.12 51637000<br />

LCC8012/00 CABLE EXT RJ12M-RJ12F 5M 0.13 51595300<br />

LCC8013/00 CABLE EXT RJ12M-RJ12F 20M 0.50 51597700<br />

LCC8011/00 CABLE INTER RJ12M-RJ12M 1M 0.03 51593900<br />

LCC8015/00 CABLE IR RJ12M-RJ12M 5M 0.12 51711700<br />

LCC8016/00 CABLE RJ12-END 3M 0.06 53920100<br />

LCC8016/10 CABLE RJ12-BL4 3M 0.06 53922500<br />

LCC8014/00<br />

Cable of 5 m length with modular plugs at both<br />

ends for the connection of sensors to the various<br />

types of light controllers.<br />

LCC8012/00/LCC8013/00<br />

Extension cables of 5 m length (LCC8012) and<br />

20 m length (LCC8013) with modular plugs and<br />

sockets to increase the distance between sensors<br />

(infrared receivers, light sensors and movement<br />

detectors) and the corresponding controllers.<br />

Product ID A<br />

LCC8012/00 5000<br />

LCC8013/00 20000<br />

LCC8011/00<br />

Interlink cable of 1 m length with modular plugs at<br />

both ends for interconnection of multifunctional light<br />

controllers so that the connected sensors can be<br />

shared by more controllers.<br />

LCC8015/00<br />

Interlink cable of 5 m length with modular plugs on<br />

both ends for interconnection of Trios light<br />

controllers.The cable is intended to distribute (only)<br />

the RC5 signal from a push-button interface over<br />

the connected controllers, especially in centrally<br />

controlled Trios applications.<br />

LCC8016/00<br />

LCC8016/10<br />

Sensor link cable of 3 m length with RJ12 connector<br />

on one end. Intended to connect general purpose<br />

sensors (excl. IRR8125) to LightMaster systems.<br />

The /00 is free end and /10 has a BL4 connector.<br />

LIGHTING CONTROLS 11.37


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.38<br />

<strong>Lighting</strong> <strong>controls</strong><br />

11.38 LIGHTING CONTROLS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!