07.08.2013 Views

JENTEC

JENTEC

JENTEC

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MODEL NO. SHEET NO 1 OF 6<br />

ISSUED DATE:<br />

<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />

POWER SUPPLY REVISED DATE:<br />

CONTAINS:<br />

1.0 INTRODUCTION<br />

2.0 INPUT REQUIREMENTS<br />

2.1 Voltage (VAC)<br />

2.2 Frequency<br />

2.3 In-Rush Current<br />

2.4 Ac Input Current<br />

3.0 OUTPUT REQUIREMENTS<br />

3.1 Output Power<br />

3.2 Output Regulation<br />

3.2.1 Input Voltage<br />

3.2.2 Input Frequency<br />

3.2.3 Static Load<br />

3.2.4 Output Voltage<br />

3.2.5 Ripple<br />

3.3 Transient Response and Deviation<br />

3.4 Turn on, Hold up Time<br />

3.5 Efficiency<br />

4.0 PROTECTION<br />

4.1 Input<br />

4.1.1 Input Current<br />

4.1.2 Input Voltage<br />

4.2 Output<br />

4.2.1 Output Voltage<br />

4.2.2 Output Current<br />

4.2.3 Short Circuit Protection<br />

5.0 ENVIRONMENTAL CONDITIONS<br />

5.1 Non-operating<br />

5.1.1 Ambient Temperature<br />

5.1.2 Relative Humidity<br />

5.2 Operating<br />

5.2.1 Ambient Temperature<br />

5.2.2 Relative Humidity<br />

6.0 EMI EMISSIONS<br />

7.0 RELIABILITY AND QUALITY CONTROL<br />

7.1 MTBF<br />

7.2 Burn-In<br />

8.0 MECHANICAL<br />

8.1 Introduction<br />

8.2 General Requirements<br />

8.3 Power Supply Dimensions<br />

8.4 Connector<br />

9.0 SAFETY<br />

9.1 Dielectric Strength (Hi-Pot) Test<br />

9.2 Insulation Resistance<br />

9.3 Leakage current<br />

10.0 PACKAGING


MODEL NO. SHEET NO 2 OF 6<br />

ISSUED DATE:<br />

<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />

POWER SUPPLY REVISED DATE:<br />

1.0 INTRODUCTION<br />

This documents specifies TWO voltage +5V,+ 12V power supply for<br />

electronic data processing equipment. The power supply will provide power to<br />

all system components.<br />

2.0 INPUT REQUIREMENTS<br />

2.1<br />

2.2<br />

2.3<br />

Input Voltage: 90~264 VAC.<br />

Line Frequency: 47 HZ to 63 HZ.<br />

In-Rush Current: 30 A max. less under 115V conditions.<br />

Interruption of the input voltage for duration sufficient to cause the output<br />

voltage to drop below the regulation setting shall cause reactivation of in<br />

rush limiting capability. ( Full-load 25 Cold-start )<br />

2.4 Input Current: 1 A max. at any line voltage specified in 2.1 at output full<br />

load condition.<br />

3.0 OUTPUT REQUIREMENTS<br />

3.1<br />

3.2<br />

Output Power<br />

The unit total output power from all voltage under steady state condition will<br />

not exceed 34 watts.<br />

Output Regulation<br />

Label Information per Safety Agencies according to UL1950 and or<br />

EN60950 Requirements.<br />

3.2.1 Input Rated Voltage Range: 100~240 VAC<br />

3.2.2 Line Rated Frequency: 50 HZ to 60 HZ.<br />

3.2.3 Static Load<br />

Output Voltage Minimum Load Maximum Load Surge Current<br />

1 + 5 0.2A 2A ------<br />

2 +12 0.1A 2A ------<br />

TABLE 3.2.4


MODEL NO. SHEET NO 3 OF 6<br />

ISSUED DATE:<br />

<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />

POWER SUPPLY REVISED DATE:<br />

3.2.4 Output Voltage<br />

The output voltage shall be statically regulated for all combinations<br />

of load(set in item 3.3.), line and environment, including cross<br />

regulation as shown:<br />

Output # Voltage Range Tolerance<br />

1 +5V +4.75~+5.25 5%<br />

2 +12V +10.8V~+13.2V 10%<br />

Table 3.2.4<br />

NOTE: Test measurement will be made at the output connector.<br />

3.2.5 Ripple and Noise<br />

Differential ripple and noise at the power supply output shall be as<br />

shown below when measured under constant load of at least 34W<br />

watts with an oscilloscope with a bandwidth of 20MHz.<br />

Output # Voltage Maximum peak to peak ripple and noise<br />

1 +5V 50mV<br />

2 + 12 V 120 mV<br />

Table 3.2.5<br />

Common mode output impedance to chassis shall be through an aluminum<br />

Electrolytic capacitor of 10uf and ceramic of 0.1uf<br />

3.3 Transient Response and Deviation<br />

The load regulation for +5V is less than +/-5% , for other outputs is less than<br />

+/-10% while the measuring is down by changing the measured output<br />

loading +20% form +100% of rated load and keep other is at +60% rated<br />

load .<br />

The load regulation for +12V is less than +/-10% , for other outputs is less<br />

than +/-5% while the measuring is down by changing the measured output<br />

loading +20% form +100% of rated load and keep other is at +60% rated<br />

load .<br />

3.4 Turn on, Hold up Time<br />

During turn on and turn off, no voltage shall exceed its nominal voltage by<br />

more than 10% and no output will change its polarity with respect to its<br />

return line. All outputs shall reach their steady state values within 2 seconds<br />

of turn on and the hold up time for the output must be at least 10 mS tested at<br />

115VAC/60HZ input with maximum load on output.


MODEL NO. SHEET NO 4 OF 6<br />

ISSUED DATE:<br />

<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />

POWER SUPPLY REVISED DATE:<br />

3.5 Efficiency<br />

The efficiency (watt out/watt in) shall be a minimum of 75 % under all line<br />

conditions and full load.<br />

4.0 PROTECTION<br />

4.1 Input<br />

4.1.1<br />

4.1.2<br />

Input Current<br />

An input fuse with a rating of 2A/250V Amps, shall be provided to<br />

protect the power supply and the input wiring. The fuse shall be an<br />

unchangeable unit.<br />

Input Voltage<br />

The power supply shall be self-protecting for any steady or dynamic<br />

variation of the input voltage below the ratings specified in paragraph<br />

2.1. The power supply shall not be damaged by differential input<br />

transients of 1.5KV with energy of 2.5 joules.<br />

4.2 Output<br />

4.2.1 Output Voltage<br />

4.2.2<br />

4.2.3<br />

The power supply shall shut down all output when any output voltage<br />

reaches to its over voltage protection trigger point.<br />

Output Current<br />

Overload conditions shall cause both the output current and the output<br />

voltages to decrease. Removal of an output overload conditions shall<br />

permit automatic recovery of the output voltage.<br />

Short Circuit Protection<br />

The power supply shall be protected from damage of accidentally<br />

shorting .<br />

5.0 ENVIRONMENTAL CONDITIONS<br />

5.1 Storage<br />

The power supply shall be capable of withstanding the following<br />

environmental conditions for extended periods of time, without sustaining<br />

electrical and/or mechanical damage and subsequent operational deficiencies:<br />

5.1.1<br />

5.1.2<br />

Ambient temperature: -25 +85<br />

Relative Humidity<br />

10% 95%


MODEL NO. SHEET NO 5 OF 6<br />

ISSUED DATE:<br />

<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />

POWER SUPPLY REVISED DATE:<br />

5.2 Operating<br />

The power supply shall be capable of operating continuously in any mode<br />

without performance deterioration in the following environmental conditions:<br />

5.2.1<br />

5.2.2<br />

6.0 EMI EMISSIONS<br />

Ambient Temperature: 0 40<br />

Relative Humidity: 25% 95%.<br />

The power supply meets the radiated and conducted emission requirements for a<br />

FCC part15B class B(DoC) and CISPR22(EN55022) class B<br />

7.0 RELIABILITY AND QUALITY CONTROL<br />

7.1<br />

7.2<br />

Reliability<br />

The design and construction of this power supply shall exhibit a<br />

minimum mean time between failure of 50,000 hours full rated load<br />

operation at 25.0, According to the MIL-HDBK-217F.<br />

Burn-in<br />

The power supply will be performed a minimum of a 4 hours burn-in at<br />

40 under full load on all power supplies.<br />

8.0 MECHANICAL<br />

8.1 Introduction Table 8.1 Pin out for DC Connector<br />

The power supply will provide PIN # Output Voltage<br />

Output power connector show as in P1 +12V<br />

Table 8.1 P2 +5V<br />

P3 RTN<br />

P4 +5V<br />

P5 RTN<br />

FRONT VIEW OF OUTPUT CONNECTOR


MODEL NO. SHEET NO 6 OF 6<br />

<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE ISSUED DATE:<br />

POWER SUPPLY REVISED DATE:<br />

8.2 General Requirements<br />

The power supply must not exceed an audible noise level of 32 dB while<br />

operating under any combination of specified load and input voltages and<br />

frequencies. This noise level shall be measured according to IEC standards<br />

651 type 1, with the sound level meter pointed directly at the power supply in<br />

a free-field condition, at a distance of 1 meter and by selecting nominal “A”<br />

weighting frequency attenuation.<br />

8.3<br />

Power Supply Dimensions<br />

The dimensions of the power supply are shown :<br />

(110x50x30 m/m)<br />

Input / Output Connection<br />

8.4<br />

AC INPUT IEC SOCKET<br />

DC OUTPUTS 5PIN MIN DIN PLUG ,4FT,BLACK<br />

8.5 Unit Color: BLACK .<br />

9.0 SAFETY<br />

The power supply must be certified or meet of the following safety standards:<br />

Certified Meet<br />

UL *<br />

CSA or CUL *<br />

CE (TUV) *<br />

PSE *<br />

BSMI *<br />

C-TICK *<br />

DOIR *<br />

EK *<br />

CE *<br />

9.1 Dielectric Strength (Hi-Pot) Test System:<br />

Withstand AC 3 K V/10mA, for 2 sec./ min., primary to secondary.<br />

9.2 Insulation Resistance:<br />

Primary to secondary: 10 MOHM at 500 VDC .<br />

9.3 Leakage current:0.25mA<br />

10.0 PACKAGING: 140*80*40mm .


DIMENSION<br />

Dimensions are in millimeter(mm)


Output PIN ASSIGNMENT


Date<br />

2005/10/17<br />

Checked by : Drawn by :


Date<br />

2005/10/17<br />

Checked by : Drawn by :

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!