JENTEC
JENTEC
JENTEC
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MODEL NO. SHEET NO 1 OF 6<br />
ISSUED DATE:<br />
<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />
POWER SUPPLY REVISED DATE:<br />
CONTAINS:<br />
1.0 INTRODUCTION<br />
2.0 INPUT REQUIREMENTS<br />
2.1 Voltage (VAC)<br />
2.2 Frequency<br />
2.3 In-Rush Current<br />
2.4 Ac Input Current<br />
3.0 OUTPUT REQUIREMENTS<br />
3.1 Output Power<br />
3.2 Output Regulation<br />
3.2.1 Input Voltage<br />
3.2.2 Input Frequency<br />
3.2.3 Static Load<br />
3.2.4 Output Voltage<br />
3.2.5 Ripple<br />
3.3 Transient Response and Deviation<br />
3.4 Turn on, Hold up Time<br />
3.5 Efficiency<br />
4.0 PROTECTION<br />
4.1 Input<br />
4.1.1 Input Current<br />
4.1.2 Input Voltage<br />
4.2 Output<br />
4.2.1 Output Voltage<br />
4.2.2 Output Current<br />
4.2.3 Short Circuit Protection<br />
5.0 ENVIRONMENTAL CONDITIONS<br />
5.1 Non-operating<br />
5.1.1 Ambient Temperature<br />
5.1.2 Relative Humidity<br />
5.2 Operating<br />
5.2.1 Ambient Temperature<br />
5.2.2 Relative Humidity<br />
6.0 EMI EMISSIONS<br />
7.0 RELIABILITY AND QUALITY CONTROL<br />
7.1 MTBF<br />
7.2 Burn-In<br />
8.0 MECHANICAL<br />
8.1 Introduction<br />
8.2 General Requirements<br />
8.3 Power Supply Dimensions<br />
8.4 Connector<br />
9.0 SAFETY<br />
9.1 Dielectric Strength (Hi-Pot) Test<br />
9.2 Insulation Resistance<br />
9.3 Leakage current<br />
10.0 PACKAGING
MODEL NO. SHEET NO 2 OF 6<br />
ISSUED DATE:<br />
<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />
POWER SUPPLY REVISED DATE:<br />
1.0 INTRODUCTION<br />
This documents specifies TWO voltage +5V,+ 12V power supply for<br />
electronic data processing equipment. The power supply will provide power to<br />
all system components.<br />
2.0 INPUT REQUIREMENTS<br />
2.1<br />
2.2<br />
2.3<br />
Input Voltage: 90~264 VAC.<br />
Line Frequency: 47 HZ to 63 HZ.<br />
In-Rush Current: 30 A max. less under 115V conditions.<br />
Interruption of the input voltage for duration sufficient to cause the output<br />
voltage to drop below the regulation setting shall cause reactivation of in<br />
rush limiting capability. ( Full-load 25 Cold-start )<br />
2.4 Input Current: 1 A max. at any line voltage specified in 2.1 at output full<br />
load condition.<br />
3.0 OUTPUT REQUIREMENTS<br />
3.1<br />
3.2<br />
Output Power<br />
The unit total output power from all voltage under steady state condition will<br />
not exceed 34 watts.<br />
Output Regulation<br />
Label Information per Safety Agencies according to UL1950 and or<br />
EN60950 Requirements.<br />
3.2.1 Input Rated Voltage Range: 100~240 VAC<br />
3.2.2 Line Rated Frequency: 50 HZ to 60 HZ.<br />
3.2.3 Static Load<br />
Output Voltage Minimum Load Maximum Load Surge Current<br />
1 + 5 0.2A 2A ------<br />
2 +12 0.1A 2A ------<br />
TABLE 3.2.4
MODEL NO. SHEET NO 3 OF 6<br />
ISSUED DATE:<br />
<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />
POWER SUPPLY REVISED DATE:<br />
3.2.4 Output Voltage<br />
The output voltage shall be statically regulated for all combinations<br />
of load(set in item 3.3.), line and environment, including cross<br />
regulation as shown:<br />
Output # Voltage Range Tolerance<br />
1 +5V +4.75~+5.25 5%<br />
2 +12V +10.8V~+13.2V 10%<br />
Table 3.2.4<br />
NOTE: Test measurement will be made at the output connector.<br />
3.2.5 Ripple and Noise<br />
Differential ripple and noise at the power supply output shall be as<br />
shown below when measured under constant load of at least 34W<br />
watts with an oscilloscope with a bandwidth of 20MHz.<br />
Output # Voltage Maximum peak to peak ripple and noise<br />
1 +5V 50mV<br />
2 + 12 V 120 mV<br />
Table 3.2.5<br />
Common mode output impedance to chassis shall be through an aluminum<br />
Electrolytic capacitor of 10uf and ceramic of 0.1uf<br />
3.3 Transient Response and Deviation<br />
The load regulation for +5V is less than +/-5% , for other outputs is less than<br />
+/-10% while the measuring is down by changing the measured output<br />
loading +20% form +100% of rated load and keep other is at +60% rated<br />
load .<br />
The load regulation for +12V is less than +/-10% , for other outputs is less<br />
than +/-5% while the measuring is down by changing the measured output<br />
loading +20% form +100% of rated load and keep other is at +60% rated<br />
load .<br />
3.4 Turn on, Hold up Time<br />
During turn on and turn off, no voltage shall exceed its nominal voltage by<br />
more than 10% and no output will change its polarity with respect to its<br />
return line. All outputs shall reach their steady state values within 2 seconds<br />
of turn on and the hold up time for the output must be at least 10 mS tested at<br />
115VAC/60HZ input with maximum load on output.
MODEL NO. SHEET NO 4 OF 6<br />
ISSUED DATE:<br />
<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />
POWER SUPPLY REVISED DATE:<br />
3.5 Efficiency<br />
The efficiency (watt out/watt in) shall be a minimum of 75 % under all line<br />
conditions and full load.<br />
4.0 PROTECTION<br />
4.1 Input<br />
4.1.1<br />
4.1.2<br />
Input Current<br />
An input fuse with a rating of 2A/250V Amps, shall be provided to<br />
protect the power supply and the input wiring. The fuse shall be an<br />
unchangeable unit.<br />
Input Voltage<br />
The power supply shall be self-protecting for any steady or dynamic<br />
variation of the input voltage below the ratings specified in paragraph<br />
2.1. The power supply shall not be damaged by differential input<br />
transients of 1.5KV with energy of 2.5 joules.<br />
4.2 Output<br />
4.2.1 Output Voltage<br />
4.2.2<br />
4.2.3<br />
The power supply shall shut down all output when any output voltage<br />
reaches to its over voltage protection trigger point.<br />
Output Current<br />
Overload conditions shall cause both the output current and the output<br />
voltages to decrease. Removal of an output overload conditions shall<br />
permit automatic recovery of the output voltage.<br />
Short Circuit Protection<br />
The power supply shall be protected from damage of accidentally<br />
shorting .<br />
5.0 ENVIRONMENTAL CONDITIONS<br />
5.1 Storage<br />
The power supply shall be capable of withstanding the following<br />
environmental conditions for extended periods of time, without sustaining<br />
electrical and/or mechanical damage and subsequent operational deficiencies:<br />
5.1.1<br />
5.1.2<br />
Ambient temperature: -25 +85<br />
Relative Humidity<br />
10% 95%
MODEL NO. SHEET NO 5 OF 6<br />
ISSUED DATE:<br />
<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE<br />
POWER SUPPLY REVISED DATE:<br />
5.2 Operating<br />
The power supply shall be capable of operating continuously in any mode<br />
without performance deterioration in the following environmental conditions:<br />
5.2.1<br />
5.2.2<br />
6.0 EMI EMISSIONS<br />
Ambient Temperature: 0 40<br />
Relative Humidity: 25% 95%.<br />
The power supply meets the radiated and conducted emission requirements for a<br />
FCC part15B class B(DoC) and CISPR22(EN55022) class B<br />
7.0 RELIABILITY AND QUALITY CONTROL<br />
7.1<br />
7.2<br />
Reliability<br />
The design and construction of this power supply shall exhibit a<br />
minimum mean time between failure of 50,000 hours full rated load<br />
operation at 25.0, According to the MIL-HDBK-217F.<br />
Burn-in<br />
The power supply will be performed a minimum of a 4 hours burn-in at<br />
40 under full load on all power supplies.<br />
8.0 MECHANICAL<br />
8.1 Introduction Table 8.1 Pin out for DC Connector<br />
The power supply will provide PIN # Output Voltage<br />
Output power connector show as in P1 +12V<br />
Table 8.1 P2 +5V<br />
P3 RTN<br />
P4 +5V<br />
P5 RTN<br />
FRONT VIEW OF OUTPUT CONNECTOR
MODEL NO. SHEET NO 6 OF 6<br />
<strong>JENTEC</strong> DESCRIPTION SWITCHING MODE ISSUED DATE:<br />
POWER SUPPLY REVISED DATE:<br />
8.2 General Requirements<br />
The power supply must not exceed an audible noise level of 32 dB while<br />
operating under any combination of specified load and input voltages and<br />
frequencies. This noise level shall be measured according to IEC standards<br />
651 type 1, with the sound level meter pointed directly at the power supply in<br />
a free-field condition, at a distance of 1 meter and by selecting nominal “A”<br />
weighting frequency attenuation.<br />
8.3<br />
Power Supply Dimensions<br />
The dimensions of the power supply are shown :<br />
(110x50x30 m/m)<br />
Input / Output Connection<br />
8.4<br />
AC INPUT IEC SOCKET<br />
DC OUTPUTS 5PIN MIN DIN PLUG ,4FT,BLACK<br />
8.5 Unit Color: BLACK .<br />
9.0 SAFETY<br />
The power supply must be certified or meet of the following safety standards:<br />
Certified Meet<br />
UL *<br />
CSA or CUL *<br />
CE (TUV) *<br />
PSE *<br />
BSMI *<br />
C-TICK *<br />
DOIR *<br />
EK *<br />
CE *<br />
9.1 Dielectric Strength (Hi-Pot) Test System:<br />
Withstand AC 3 K V/10mA, for 2 sec./ min., primary to secondary.<br />
9.2 Insulation Resistance:<br />
Primary to secondary: 10 MOHM at 500 VDC .<br />
9.3 Leakage current:0.25mA<br />
10.0 PACKAGING: 140*80*40mm .
DIMENSION<br />
Dimensions are in millimeter(mm)
Output PIN ASSIGNMENT
Date<br />
2005/10/17<br />
Checked by : Drawn by :
Date<br />
2005/10/17<br />
Checked by : Drawn by :