Cleaning and Maintenance<br />

7. Cleaning and Maintenance<br />

7.1 Cleaning<br />

63 9810.0156 – Rev.04 –12/01/2007<br />

Electricshock Danger! Before protective hat and<br />

pieces of cover is taken out, all electrical connections on<br />

boiler must be disassembled. Works that will be done when<br />

electric is on, must be carried on by authorized people after<br />

all necessary precuations are supplied.<br />

Cleaning consists of items below;<br />

- Cleaning of the boiler from outside,<br />

- Cleaning of combustion chamber and pipes of the<br />

boiler ( this may change depending on operation).<br />

It is strongly advised that cleaning and<br />

maintenance of boiler must be done once in a year by<br />

authorized services.<br />

Attention: Insulation of front cover was made by<br />

a material that is not required to be cleaned. Therefore,<br />

do not clean with any shape or corrosive tool, do not<br />

apply force or pressurized air, do not clean with fluids<br />

like water, etc. In case of damage on cover insulation,<br />

boiler will be out of warranty.<br />

For cleaning of combustion chamber in boiler room,<br />

open boiler cover, pull and take out turbulators with tools<br />

which was delivered with the boiler. After turbulators are<br />

taken out, clean them with a brush and brush holder, clean<br />

smut and dirts accumulating to the side of flume hood<br />

taking out the explotion hoot then repeating all the works<br />

from reverse, assemble explosition hoot and turbulators,<br />

close boiler cover and after bolts are tighten check if there<br />

is gas leakage from connections.<br />

See figure of turbulator assemble for process of<br />

connection and disconnection of turbulators.<br />

Burner must be checked for impurity, cleaned and<br />

processed to maintenance if it is necessary.<br />

In case of necessity, clean boilers from outside.<br />

Use only soft cleaning materials which will not damage to<br />

surface. Cleaning of surfaces, heating the inside of the<br />

boiler and burner, must be only done by authorized<br />

service.<br />