Installation<br />

3.6 Gas Blown Burners<br />

CAUTION! Use only fluid or gas fuel burner that<br />

is avaliable at CE norms. Burner ignition power must be<br />

set according to nominal heat efficiency of boiler.<br />

Please take care boiler mounting manual while<br />

installing boiler.<br />

Burners must be set according to nominal heat<br />

efficiency of boiler on low heat conditions. Power of 1st<br />

stage burner must be upper than 66% of boiler nominal<br />

power for two stage burner.<br />

Waste gas temperature value must not be lower<br />

than 160 °C for ordinary chimney.<br />

Height of chimney must be set properly for<br />

preventing condensation in chimney.<br />

Open the boiler cover and remove some rotarders<br />

from bottom pipes of front plate on required situation<br />

( Note : Number of removed rotarder must not<br />

exceed much more than 25% boiler pipes quantity. )<br />

Installation of suction limitation cover and<br />

additional air mechanism are recommended. Chimney<br />

must be avaliable for processof waste gas at two stage<br />

burner applications.<br />

Explosion cover setup of the boiler must not be<br />

changed and dont put any object to the front side of<br />

cover.<br />

3.7 Related demands for fuels that is used<br />

63 9810.0156 – Rev.04 –12/01/2007<br />

Fuels that is used must be convenable to<br />

defined norms. Otherwise; boiler will be out of<br />

guaranty conditions. Manufacturer company is not<br />

responsible for phisical or sipiritual damages.<br />

Coal gas , natural gas and LPG must be<br />

convenable to EN 437 norm or avaliable for local laws<br />

For fluid fues; Diesel fuel and fuel oil<br />

corresponding to DIN 51603 must be used<br />

Attention ! Fuel-oil and/or heavy oil fuels which is not<br />

in standards can not be used for boilers.<br />

Additive materials are recommended on conditions below<br />

- If they increase durability of fuel storage<br />

- If they increase termic resistance of fuel or reduce<br />

smell formation as tank is filled and provide the burning<br />

without sediment,<br />

Additive material causing sediment or ruin is<br />

forbidden<br />

Attention! It is not allowed to use fuel oil with<br />

Yakut/Elmas 6/8/10 series. Otherwise boiler will be out<br />

of warranty and manufacturer company is not<br />

responsible for physical and sipirutal damages.<br />