<strong>Low</strong> <strong>Profile</strong> Fan Coils<br />

SPECIFICATION DATA<br />

SINGLE PHASE THREE PHASE<br />

MODEL ADA8 ADA9.5 ADA11 ADA13 ADA14 ADA15<br />

H.P. 2.75 3.2 3.8 4.4 4.4 5.0<br />

Nominal Cooling (kW) 1) 8.0 9.6 11.1 13.0 13.2 15.5<br />

Nominal Heating (kW) 1) 8.4 10.1 11.6 13.5 13.6 15.9<br />

Nett Cooling Capacity (kW) 2) 7.1 8.45 9.7 12.18 13.12 13.7<br />

Nett Heating Capacity (kW) 2) 7.57 9.1 10.6 12.29 13.38 14.2<br />

<strong>Air</strong> Flow High (l/s) 400 470 490 630 630 750<br />

<strong>Air</strong> Flow <strong>Low</strong> (l/s) 180 275 290 450 450 600<br />

ELECTRICAL DATA SINGLE PHASE THREE PHASE<br />

Power Supply 240 Volts -1 Phase - 50 Hz 415 Volts - 3 Phase - 50 Hz<br />

Nom. Full Load Amps 3) 17 18 20 23 12 13<br />

Minimum Circuit Size (Amps) 25 25 32 32 20 20<br />

Electrical Input Cooling (kW) 2) 2.69 3.2 3.7 4.31 5.03 5.23<br />

Electrical Input Heating (kW) 2) 2.55 3.05 3.47 3.7 4.37 4.62<br />

Sound Pressure dB(A) 51 51 52 49 49 51<br />

DIMENSIONS (MM)<br />

Outdoor Unit Length 1000 1150<br />

Width 400 565<br />

Height 800 960<br />

Weight (kg) 88 89 90 98.5 103.5 110<br />

Indoor Unit Length 1170 1470<br />

Width 450 450<br />

Height 250 250<br />

Weight (kg) 32.5 45.5<br />

Supply <strong>Air</strong> Size (mm) L x H 710 x 185 1050 x 185<br />

Return <strong>Air</strong> Size (mm) L x H 1000 x 195 1300 x 195<br />

Information on this table may be subject to change without notice. Please consult <strong>Accent</strong> <strong>Air</strong>.<br />

DESIGN CONDITIONS<br />

Cooling 35°C DB Outdoor / 27° C DB, 19°C WB <strong>Air</strong> Entering Indoor Unit<br />

Heating 7°C DB, 6°C WB Outdoor / 21°C DB <strong>Air</strong> Entering Indoor Unit<br />

Operating Range -10°C WB to 50°C DB<br />

Sound pressure level is influenced by the surroundings; therefore it may vary upon the location.<br />

Single Phase units may require a soft starter, please check with your local energy supplier.<br />

1) Nominal kW related to the compressor capacity<br />

2) Net Capacities are based on A.S.3823.1.2<br />

3) Full Load Amps taken from Highest Phase<br />

HEAD OFFICE: ACCENT AIR PTY LTD<br />

21 ATKINSON STREET, LIVERPOOL NSW 2170, AUSTRALIA<br />

PHONE: 61 2 9602 8444 FAX: 61 2 9602 8477<br />

EMAIL: sales@accentair.com.au<br />

WEB: www.accentair.com.au