SwitchBox-USB-USB - antrax.de
SwitchBox-USB-USB - antrax.de
SwitchBox-USB-USB - antrax.de
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>antrax</strong> Datentechnik GmbH<br />
info@<strong>antrax</strong>.<strong>de</strong> - www.<strong>antrax</strong>.<strong>de</strong><br />
<strong>SwitchBox</strong>-<strong>USB</strong>-<strong>USB</strong><br />
• relay version<br />
• <strong>USB</strong> interface<br />
Manual<br />
12.07.2005<br />
- 1 -<br />
Hasenbrink 4, 32052 Herford, Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628
<strong>antrax</strong> Datentechnik GmbH<br />
info@<strong>antrax</strong>.<strong>de</strong> - www.<strong>antrax</strong>.<strong>de</strong><br />
General<br />
The <strong>SwitchBox</strong>-<strong>USB</strong> allows the input and switching off a electronic <strong>de</strong>vice via <strong>USB</strong> interface of<br />
a PC. Timer-controlled switching operations by the parallel and serial interfaces via the free of<br />
charge <strong>SwitchBox</strong>-<strong>USB</strong> service program (download on the <strong>antrax</strong> homepage)<br />
Before first use of the <strong>SwitchBox</strong>-<strong>USB</strong>, please read this instruction manual or the help file<br />
(found on our homepage). It contains information for the correct use and contains important<br />
tips for the installation of the <strong>SwitchBox</strong>-<strong>USB</strong>. The manufacturer does not accept any liability<br />
due to improper use of the unit. In this case all guarantee claims are invalid.<br />
Use of the <strong>SwitchBox</strong>-<strong>USB</strong><br />
The <strong>SwitchBox</strong>-<strong>USB</strong> is inten<strong>de</strong>d for switching of resistive and inductive loads up to maximum<br />
2000W (230V/8.5A) in dry and closed housing space and offices. Activation may only be set up<br />
via the <strong>USB</strong>-bus. Operating instructions of the connected electronic <strong>de</strong>vices and their safety<br />
regulations must be respected.<br />
Safety Instructions<br />
Caution<br />
� Do not open the <strong>SwitchBox</strong>-GSM. It contains no parts to be serviced by you.<br />
� Only use the <strong>SwitchBox</strong>-GSM indoors and do not subject the unit to moisture or<br />
humidity.<br />
� Only connect the <strong>SwitchBox</strong>-GSM to properly installed 230V AC outlets.<br />
� Only clean the exterior of the <strong>SwitchBox</strong>-GSM with a dry cloth after unplugging it<br />
from the electrical outlet and removal of the interface cable.<br />
� Do not overload the <strong>SwitchBox</strong>-GSM above its load specification level. An<br />
overload can lead to the <strong>SwitchBox</strong>-GSM being <strong>de</strong>stroyed.<br />
� Do not use the <strong>SwitchBox</strong>-GSM in areas used by children.<br />
� Do not connect the <strong>SwitchBox</strong>-GSM to a computer that is already switched on.<br />
This can lead to computer components becoming damaged or <strong>de</strong>stroyed.<br />
� Do not use the <strong>SwitchBox</strong>-GSM if one or several parts (case, cable, plug) are<br />
damaged or damage may be caused by its location (e.g., falling down).<br />
� The <strong>SwitchBox</strong>-GSM may only be repaired by authorized service personnel.<br />
� Only connect electrical appliances that have no limit to their switched-on time (i.e.<br />
all connected electrical appliances must be able to take continuous current without<br />
sustaining damage in the case of a <strong>de</strong>fault to the permanently “ON” position).<br />
� Never operate the <strong>SwitchBox</strong>-<strong>USB</strong>, if malfunction/error of the box may cause<br />
damage on people or material.<br />
� The load circuit is switched about a single-pole electrical relay, therefore even when the<br />
<strong>SwitchBox</strong>-<strong>USB</strong> outlet is switched to off there can still be a mains voltage on one of the<br />
outlet sockets!<br />
� When the <strong>SwitchBox</strong>-<strong>USB</strong> is controlled via a PC/computer, this <strong>de</strong>vice <strong>de</strong>termines the<br />
- 2 -<br />
Hasenbrink 4, 32052 Herford, Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628
<strong>antrax</strong> Datentechnik GmbH<br />
info@<strong>antrax</strong>.<strong>de</strong> - www.<strong>antrax</strong>.<strong>de</strong><br />
switching state of the load circuit during and after booting of the system. Depending on<br />
the behaviour of the used computer (or the BIOS), the operating system, <strong>de</strong>vice drivers<br />
for the interfaces and other programs, while booting short-term or permanent switching of<br />
the load is possible. The <strong>de</strong>cisive switching state of the load is only achieved by the start<br />
of the <strong>SwitchBox</strong>-<strong>USB</strong> service program.<br />
� Very fast ON/OFF switching sequences can be controlled with the <strong>SwitchBox</strong>-<strong>USB</strong>. The<br />
duration of the switching cycles is to be adjusted to the controlled <strong>de</strong>vice. Not all<br />
electronic <strong>de</strong>vices tolerate rapid switching sequences.<br />
� In<strong>de</strong>pen<strong>de</strong>nt from the previous switching state the <strong>SwitchBox</strong>-<strong>USB</strong> will always switch<br />
OFF the connected 230V consumer after a “Power-ON”.<br />
Package Content<br />
� 1 pcs. <strong>SwitchBox</strong>-<strong>USB</strong><br />
� this manual<br />
Software<br />
The required driver ("SBOX_<strong>USB</strong>.DLL" and "<strong>USB</strong>access.DLL") an the free of charge software for<br />
controlling the <strong>SwitchBox</strong>-<strong>USB</strong> can be downloa<strong>de</strong>d from our web page at www.<strong>antrax</strong>.<strong>de</strong><br />
Installation of the <strong>SwitchBox</strong>-<strong>USB</strong><br />
� Connectec the <strong>SwitchBox</strong>-<strong>USB</strong> to the <strong>USB</strong>-bus of the PC (the PC may be switched ON<br />
or OFF), however the <strong>SwitchBox</strong>-<strong>USB</strong> must not yet be connected to a 230V socket.<br />
� The PC recognises the <strong>USB</strong> <strong>SwitchBox</strong> as "<strong>USB</strong> Switch" and "HID" (human interface<br />
<strong>de</strong>vice).<br />
� Copy the two required drivers<br />
- SBOX_<strong>USB</strong>.DLL<br />
- <strong>USB</strong>access.DLL<br />
in the system directory (e.g. C:\WINDOWS\SYSTEM or C:\WINDOWS\SYSTEM32) to the<br />
PC. Additional drivers are not requested!<br />
� Start the service program "<strong>SwitchBox</strong><strong>USB</strong>.exe". This program consists of only one file, no<br />
entries in the registry or elsewhere are ever ma<strong>de</strong> by starting this program, there is no<br />
"installation". The program can easily be copied to any subdirectories and be erased free<br />
of residues.<br />
� The service program displays all <strong>de</strong>tected <strong>USB</strong> <strong>SwitchBox</strong>es with their serial numbers.<br />
Select the serial number you want to switch from the list and use the "ON" / "OFF"<br />
buttons for the selected box. The LED of the <strong>SwitchBox</strong>-<strong>USB</strong> changes color <strong>de</strong>pending on<br />
the current switching state: RED (=off) to GREEN (=on).<br />
� If everything works out fine: Plug the electronic <strong>de</strong>vice tot he <strong>SwitchBox</strong>-<strong>USB</strong> and<br />
connect the <strong>SwitchBox</strong>-<strong>USB</strong> into a 230V outlet.<br />
- 3 -<br />
Hasenbrink 4, 32052 Herford, Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628
<strong>antrax</strong> Datentechnik GmbH<br />
info@<strong>antrax</strong>.<strong>de</strong> - www.<strong>antrax</strong>.<strong>de</strong><br />
Physical Characteristics<br />
General:<br />
• Protection class: IP20, in dry rooms only<br />
• Connector system: safety plug (CEE 714)<br />
• Current switching state is indicated by green/red LED<br />
• Load and control circuit have a safe electronic isolation over the switch relay<br />
• Ambient temperature 0 ... +40°C<br />
• Storage temperature -10 ... +70°C<br />
Load Circuit:<br />
• Operating voltage: 230/240V~ 50/60Hz<br />
• Single pole electronic switch (relay)<br />
• Maximum switching power: 2000W (8.5A at 230/240V)<br />
Control Circuit:<br />
• <strong>USB</strong> controlled<br />
• Maximum power over <strong>USB</strong>, operating: approx. 150mA<br />
• Each <strong>SwitchBox</strong>-<strong>USB</strong> has a unique serial number<br />
CE Marking<br />
In accordance with the low-voltage and EMC directive.<br />
- 4 -<br />
Hasenbrink 4, 32052 Herford, Germany Tel. +49 (0) 5221 929660 Fax +49 (0) 5221 9296628