1.14.6 M3000 Filter Error Flowchart<br />
Fryer returns to<br />
cook mode for 4<br />
minutes or 15<br />
minutes if pad<br />
change expired.<br />
SIXTH<br />
CONSECUTIVE<br />
FILTER ERROR<br />
NORMAL<br />
OPERATION<br />
RESUMES<br />
Change filter pad and<br />
ensure filter pan is<br />
pulled out for a<br />
minimum of 30<br />
seconds.<br />
This chart follows the process of clearing a filtration<br />
issue. The prompt is displayed when any of the<br />
following occur:<br />
1. a clogged filter pad,<br />
2. a tripped or defective filter pump,<br />
3. a leaky O-ring on the pick-up tube,<br />
4. a failed drain valve/actuator, or<br />
5. a failed return valve/actuator.<br />
1-37<br />
TECH<br />
ENTERS<br />
CODE<br />
MESSAGE<br />
DISPLAYED<br />
Call an Authorized<br />
Repair Technician<br />
Fryer returns to<br />
cook mode for 15<br />
minutes.<br />
If the computer displays SERVICE<br />
REQUIRED, the fryer can be used in<br />
most cases by answering NO when the<br />
prompt for SYSTEM ERROR<br />
FIXED? YES NO is displayed. The<br />
message repeats every 15 minutes until<br />
the issue is repaired and error cleared by<br />
a technician. To clear the error, enter<br />
1111 after answering YES when<br />
SYSTEM ERROR FIXED? YES<br />
NO is displayed.