1.14.6 M3000 Filter Error Flowchart<br />

Fryer returns to<br />

cook mode for 4<br />

minutes or 15<br />

minutes if pad<br />

change expired.<br />

SIXTH<br />

CONSECUTIVE<br />

FILTER ERROR<br />

NORMAL<br />

OPERATION<br />

RESUMES<br />

Change filter pad and<br />

ensure filter pan is<br />

pulled out for a<br />

minimum of 30<br />

seconds.<br />

This chart follows the process of clearing a filtration<br />

issue. The prompt is displayed when any of the<br />

following occur:<br />

1. a clogged filter pad,<br />

2. a tripped or defective filter pump,<br />

3. a leaky O-ring on the pick-up tube,<br />

4. a failed drain valve/actuator, or<br />

5. a failed return valve/actuator.<br />

1-37<br />

TECH<br />

ENTERS<br />

CODE<br />

MESSAGE<br />

DISPLAYED<br />

Call an Authorized<br />

Repair Technician<br />

Fryer returns to<br />

cook mode for 15<br />

minutes.<br />

If the computer displays SERVICE<br />

REQUIRED, the fryer can be used in<br />

most cases by answering NO when the<br />

prompt for SYSTEM ERROR<br />

FIXED? YES NO is displayed. The<br />

message repeats every 15 minutes until<br />

the issue is repaired and error cleared by<br />

a technician. To clear the error, enter<br />

1111 after answering YES when<br />

SYSTEM ERROR FIXED? YES<br />

NO is displayed.