1.14.3 Service Required Errors<br />
A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the<br />
alarm is silenced. The computer displays an error message from the list below three times with the<br />
location of the error. Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen,<br />
enter code 1111. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error<br />
until issue is fixed.<br />
Pressing the MIB reset button during any filter function will generate a “SERVICE REQUIRED”<br />
error.<br />
This is a list of the service required errors and causes.<br />
ERROR MESSAGE EXPLANATION<br />
PUMP NOT FILLING Oil not returning to vat quickly. Possible<br />
problems: dirty pad, bad or missing O-rings,<br />
tripped or defective filter pump, actuators or<br />
linkage.<br />
DRAIN VALVE NOT OPEN Drain valve failed to open; the valve’s<br />
position is unknown.<br />
DRAIN VALVE NOT CLOSED Drain valve failed to close; the valve’s<br />
position is unknown.<br />
RETURN VALVE NOT OPEN Return valve failed to open; the valve’s<br />
position is unknown.<br />
RETURN VALVE NOT CLOSED Return valve failed to close; the valve’s<br />
position is unknown.<br />
MIB BOARD Problem with CAN communications; Check<br />
for loose CAN connections between<br />
computer and MIB board. MIB board failure<br />
AIF BOARD MIB detects AIF missing; AIF board failure<br />
ATO BOARD MIB detects ATO board connection lost;<br />
ATO board failure<br />
HIGH LIMIT FAILURE High limit circuit has an issue<br />
AIF PROBE AIF RTD reading out of range<br />
ATO PROBE ATO RTD reading out of range<br />
TEMP PROBE FAILURE TEMP Probe reading out of range<br />
MIB SOFTWARE Internal MIB software error<br />
INVALID CODE LOCATION SD card removed during update<br />
MISCONFIGURED ENERGY TYPE Energy type in fryer setup is incorrect. (ie.<br />
Set proper energy type gas or electric)<br />
Press 1234 to enter setup to properly<br />
configure fryer.<br />
RTC INVALID DATE The date is invalid. Press 1234 to enter<br />
setup to properly configure fryer and set<br />
proper date.<br />
1-34