8. “Filling” is displayed during fill.<br />

9. Release button to stop filling.<br />

10. “Continue Filling? Yes/No” is displayed.<br />

11. Press “” to exit.<br />

FILL JUG FROM BULK:*<br />

1. When “Orange” indicator light is on, the top-off jug is empty.<br />

2. To refill jug press and hold the orange reset button above the jug until the jug is full.<br />

3. Release the button to stop filling.<br />

*NOTE: The jug may not fill if any of the following are in progress:<br />

If FILTER NOW? YES/NO, CONFIRM YES/NO, or SKIM VAT is displayed, the fill jug button is disabled until either a<br />

filter is complete or until no is chosen.<br />

The system also checks these conditions. The following must be met before jug fill is allowed.<br />

Solenoid closed<br />

• Orange fill button pressed longer than 3 sec.<br />

• Waste valve closed<br />

• Filter Now? Yes/No, Confirm Yes/No, or Skim Vat cannot be displayed<br />

• System power cycle (all boards – computers, MIB, AIF and ATO) after changing setup from JIB to Bulk (use<br />

momentary reset). Ensure reset is pressed and held for at least ten seconds.<br />

• No filtration or other filter menu selection can be in process.<br />

Other factors that may not allow fill jug from bulk –<br />

• Defective solenoid<br />

• Defective switch<br />

• RTI pump issue<br />

• RTI relay stuck<br />

If using two fryer systems that are both attached to the RTI system, they may not be able to fill both units at the same<br />

time if they have an RTI unit with a single head. Some RTI units have dual heads which can fill simultaneously.<br />