1.11.4 MIB (Manual Interface Board) Display Diagnostics<br />

DISPLAY LED EXPLANATION<br />

Drain<br />

Vat # (The vat number is followed by<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

On Drain valve on vat # is open<br />

Vat # (The vat number is followed by<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

Off Drain valve on vat # is closed<br />

Vat # (The vat number is followed by Blink Drain valve on vat # is opening or closing or an<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

Return<br />

error condition may exist.<br />

Vat # (The vat number is followed by<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

On Return valve on vat # is open<br />

Vat # (The vat number is followed by<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

Off Return valve on vat # is closed<br />

Vat # (The vat number is followed by Blink Return valve on vat # is opening or closing or an<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

Network<br />

error condition may exist<br />

N<br />

Resetting<br />

Network error, displays for 10 seconds if no<br />

communications are received from the M3000<br />

within 10 seconds after power on or MIB reset.<br />

r<br />

Miscellaneous<br />

An “r” is displayed for ten seconds or until<br />

communication is received from the M3000 after a<br />

power on or MIB reset.<br />

E alternating with vat # (The vat Blink The circuit has an issue. Ensure the actuator is<br />

number is followed by an “L” to<br />

plugged in. Ensure the CAN connections are all<br />

indicate left side of a split vat or an<br />

“r” to indicate the right side of a split<br />

vat or a full vat.)<br />

securely plugged into the connectors.<br />

Indicates the AIF temperature sensor did not detect<br />

a full vat during filtration.<br />

A Manual LED off The system is in auto filtration mode.<br />

Vat # (The vat number is followed by<br />

an “L” to indicate left side of a split<br />

vat or an “r” to indicate the right side<br />

of a split vat or a full vat.)<br />

Manual LED on The system is in manual mode.<br />

P This will only be displayed in auto filtration mode.<br />

Filter pan is improperly seated. Any auto filtration<br />

messages received at this time are ignored.<br />