Problem Probable Causes Corrective Action<br />

Frypots won’t top off.<br />

One vat doesn’t top off.<br />

M3000 displays<br />

SERVICE<br />

REQUIRED – ATO<br />

BOARD<br />

A. Empty JIB.<br />

B. Probe temperature lower than setpoint.<br />

C. Oil is too cold.<br />

D. Bad Connection<br />

E. ATO board power loss<br />

F. Failed transformer/harness<br />

G. ATO pump failed<br />

H. Failed ATO board.<br />

A. Filter error exists.<br />

B. Actuator, pump, loose connection, RTD<br />

or ATO issue.<br />

A. Loose or bad fuse<br />

B. Bad Connection<br />

C. ATO Board power loss<br />

1-14<br />

A. Ensure JIB has oil.<br />

B. Check to see that fryer is heating.<br />

Fryer temperature must be at setpoint.<br />

Check probe resistance. If probe is<br />

bad, replace the probe.<br />

C. Ensure that the oil in the JIB is above<br />

70°F (21°C).<br />

D. With the computer OFF, press TEMP<br />

button and ensure the ATO software<br />

version appears. If not, the connection<br />

between the AIF and the ATO board<br />

may be bad. Ensure the 6-pin CAN<br />

connectors are tight between AIF (J4<br />

and J5) and ATO (J10) boards.<br />

E. Power to the ATO board has been cut<br />

off. Restore power to the board and<br />

clear any service required errors.<br />

F. Ensure transformer in ATO box is<br />

functioning properly. Check power<br />

from transformer to ATO board.<br />

Ensure all harnesses are plugged<br />

securely into place.<br />

G. Ensure pump is operational. Check<br />

voltage to pump. Replace the pump if<br />

defective.<br />

H. Check for proper voltages using the pin<br />

position chart found on page 1-15. If<br />

ATO found defective, replace ATO<br />

board and clear any errors.<br />

A. Clear filter error properly. When<br />

change filter pad YES/NO is displayed,<br />

do NOT press any button until the pan<br />

has been removed for at least thirty<br />

seconds. After thirty seconds have<br />

elapsed, the computer returns to OFF or<br />

last display.<br />

B. Check actuator, ATO pump, wire<br />

connections, RTD and ATO board.<br />

A. Ensure fuse on right side of ATO box is<br />

secure and good. If the computer<br />

above the ATO box is missing power<br />

check the fuse below the component<br />

box.<br />

B. With the computer OFF, press TEMP<br />

button and ensure the ATO software<br />

version appears. If not, the connection<br />

between the AIF and the ATO board<br />

may be bad. Ensure the 6-pin CAN<br />

connectors are tight between AIF (J4<br />

and J5) and ATO (J9 or J10) boards.<br />

C. Power to the ATO board has been cut<br />

off. Ensure there is correct voltage to<br />

the ATO transformer. Restore power to<br />

the board and clear any service required<br />

errors.