Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Disconnect flexlines indicated by the arrows.<br />
4. Loosen the nut and bolt which secure the bridge to the oil-return manifold.<br />
5. Remove the cover plate from the front of the motor and disconnect the motor wires.<br />
6. Remove the two nuts and bolts which secure the front of the bridge to the cross brace and carefully<br />
slide the bridge rearward off the cross brace until its front end can be lowered to the floor. Undo<br />
the single nut holding it in place in back. Be careful not to let the rear of the bridge slip off the<br />
manifold at this point.<br />
7. Get a good grip on the bridge, carefully pull it forward off the oil-return manifold, and lower the<br />
entire assembly to the floor. Once on the floor, pull the assembly out the front of the fryer.<br />
8. When required service has been completed, reverse steps 4-7 to reinstall the bridge.<br />
9. Reconnect the unit to the electrical power supply, and verify that the pump is functioning correctly<br />
using the MIB board in manual mode (i.e., using the fill function when engaged, the motor should<br />
start and there should be strong suction at the intake fitting and outflow at the rear flush port.)<br />
10. When proper operation has been verified, reinstall the back panels and the filter pan and lid.<br />
11. Reconnect it to the electrical power supply and reposition the fryer under the exhaust hood to<br />
return the fryer to service.<br />
1.9.3 Replacing the Transformer or Filter Relay<br />
Disconnect the fryer from the electrical power supply. Remove the left computer from the fryer to<br />
expose the interior of the left component box. The transformer and relay on the left are located as<br />
shown in the illustration on the next page. NOTE: The right component box is identical to the left<br />
except that the transformer and relay on the left side are not present. Once replaced, reconnect the<br />
power.<br />
When replacing a filter relay in the left component box, ensure the 24VDC relay (8074482) is used.<br />
Similar <strong>Frymaster</strong> fryers use a 24VAC relay, which can lead to confusion. The 24VDC is used in the<br />
LOV fryer.<br />
1-12