Section 4: Replenisher System<br />
G128_4306HCA<br />
G128_4306HC<br />
PROCESSOR<br />
TANK<br />
VALVE<br />
CHECK<br />
VALVE<br />
3 WAY<br />
VALVE<br />
CAL<br />
BIB<br />
FLOW<br />
MONITOR<br />
Replenisher System<br />
The REPLENISHER SYSTEM maintains chemistry at the correct strength in relation to the film that runs through<br />
the PROCESSOR. A single-board computer in the REPLENISHER RACK determines replenisher rates. Depending<br />
on the amount of film and film type, the appropriate REPLENISHER PUMP energizes. The PUMP pumps the<br />
REPLENISHER chemistry from the BIB through the PUMP, through a FLOW MONITOR, through 3-WAY<br />
VALVE and QUICK DISCONNECT, through a series of CHECK VALVES and HOSES, and into the bottom of the<br />
TANK. The FILM DETECTOR, at the entrance of the wet section, detects the amount of film. The FILM<br />
DETECTOR sends a signal to the SBC as to whether the PROCESSOR is transporting film or leader. When the film<br />
is spliced, the type of film is detected. This data is input into the computer at the start of a film batch.<br />
TG2044-1 – 06APR99 15<br />
RUN<br />
PUMP<br />
QUICK<br />
DISCONNECT<br />
CHECK<br />
VALVE