120<br />
storing <strong>the</strong> blowdown mterialb that would result froan a lnajQK Steam leak<br />
in <strong>the</strong> steam generator.<br />
Account 22, Reactor plant equipment, The reactor and associated<br />
heat-transfer system costs have been updated from <strong>the</strong> 1978 estimate using<br />
a multiplier ~f 2.5.<br />
been added for engineered safety features (which were not previoaas~y con-<br />
sidered) and for larger salt volunes, %his amount also covers external<br />
heat dissipation equipment €‘or engineered safety features. Radioactive<br />
waste handlf~g in <strong>the</strong> DMSR was estimated ta cost about <strong>the</strong> same as radio-<br />
active waste processing for <strong>the</strong> PWR.<br />
About 10% of this total (accounts 221 and 222) has<br />
Fuel handling and storage and maintenance equipment were updated from<br />
<strong>the</strong> MSBR estimate using <strong>the</strong> 2.5 multiplier. An allowance was made for <strong>the</strong><br />
control features necessary for making <strong>the</strong> plant operate 011 <strong>the</strong> salt-steam<br />
cycle e<br />
Account 23. Turbine plant equipment. This account parallels <strong>the</strong><br />
coal plant case, whish uses supercritical steam-cycle equipment. The<br />
feed-heating account was increased 50% to allow for<br />
tures pesultar to <strong>the</strong> <strong>Salt</strong>-%QQp applicati0R.<br />
Account 24. Electric plant equipment. Except<br />
25 Mwe of electric heating associated with <strong>the</strong> salt<br />
similar to <strong>the</strong> PWR case.<br />
operating design fea-<br />
for provision of about<br />
loops, this account is<br />
Account 25. Miscellaneous plant equipment. The auxiliary steam sup-<br />
ply cost for <strong>the</strong> PWW has been increased to adjust <strong>the</strong> PWR cost to <strong>the</strong> DMSR<br />
basis<br />
Account 26. Main condenser heat rejection system. Design for <strong>the</strong><br />
coal plant is comparable to <strong>the</strong> DMSW; <strong>the</strong>refore, <strong>the</strong> same costs have been<br />
assumed e<br />
Accounts 91, 92, and $3, Indirect costs. The DMSR costs are based<br />
on PWR costs adjusted upward for those accounts in which higher labor re-<br />
quirements are anticipated.<br />
5,3.2 ESo~fuel oloeration and maintenance cost<br />
Estimates of nonfuel operation and maintenance (06M) costs of 2.82<br />
wills/kh% are based on <strong>the</strong> single-unit base-load plant. me procedure<br />