120<br />

storing <strong>the</strong> blowdown mterialb that would result froan a lnajQK Steam leak<br />

in <strong>the</strong> steam generator.<br />

Account 22, Reactor plant equipment, The reactor and associated<br />

heat-transfer system costs have been updated from <strong>the</strong> 1978 estimate using<br />

a multiplier ~f 2.5.<br />

been added for engineered safety features (which were not previoaas~y con-<br />

sidered) and for larger salt volunes, %his amount also covers external<br />

heat dissipation equipment €‘or engineered safety features. Radioactive<br />

waste handlf~g in <strong>the</strong> DMSR was estimated ta cost about <strong>the</strong> same as radio-<br />

active waste processing for <strong>the</strong> PWR.<br />

About 10% of this total (accounts 221 and 222) has<br />

Fuel handling and storage and maintenance equipment were updated from<br />

<strong>the</strong> MSBR estimate using <strong>the</strong> 2.5 multiplier. An allowance was made for <strong>the</strong><br />

control features necessary for making <strong>the</strong> plant operate 011 <strong>the</strong> salt-steam<br />

cycle e<br />

Account 23. Turbine plant equipment. This account parallels <strong>the</strong><br />

coal plant case, whish uses supercritical steam-cycle equipment. The<br />

feed-heating account was increased 50% to allow for<br />

tures pesultar to <strong>the</strong> <strong>Salt</strong>-%QQp applicati0R.<br />

Account 24. Electric plant equipment. Except<br />

25 Mwe of electric heating associated with <strong>the</strong> salt<br />

similar to <strong>the</strong> PWR case.<br />

operating design fea-<br />

for provision of about<br />

loops, this account is<br />

Account 25. Miscellaneous plant equipment. The auxiliary steam sup-<br />

ply cost for <strong>the</strong> PWW has been increased to adjust <strong>the</strong> PWR cost to <strong>the</strong> DMSR<br />

basis<br />

Account 26. Main condenser heat rejection system. Design for <strong>the</strong><br />

coal plant is comparable to <strong>the</strong> DMSW; <strong>the</strong>refore, <strong>the</strong> same costs have been<br />

assumed e<br />

Accounts 91, 92, and $3, Indirect costs. The DMSR costs are based<br />

on PWR costs adjusted upward for those accounts in which higher labor re-<br />

quirements are anticipated.<br />

5,3.2 ESo~fuel oloeration and maintenance cost<br />

Estimates of nonfuel operation and maintenance (06M) costs of 2.82<br />

wills/kh% are based on <strong>the</strong> single-unit base-load plant. me procedure<br />