ANP PROJECT PROGRESS REPORT<br />

Experimental transient wall and fluid temper-<br />

ature data are shown in Fig. 4.1.10 in terms of <strong>the</strong><br />

total temperature fluctuation divided by <strong>the</strong> axial<br />

temperature rise of <strong>the</strong> fluid going through <strong>the</strong><br />

core. The frequencies of <strong>the</strong> temperature fluctu-<br />

ations for this one-half-scale volume-heat-source<br />

system vary from about \ to 4 cps. The frequency<br />

range of temperature fluctuations in <strong>the</strong> full-scale<br />

ART system operating with fluoride fuel should be<br />

similar to that in <strong>the</strong> one-half-scale volume-heat-<br />

I ISLANDSHELLATEQUATOR I I<br />

+OUTER GORE SHELL AT EQUATOR -4<br />

0 4.0 2.0 3.0<br />

TIME (sec)<br />

source system in which an acid was circulated.<br />

The frequencies of <strong>the</strong> temperature fluctuations<br />

were found to be in agreement with <strong>the</strong> frequencies<br />

of <strong>the</strong> velocity fluctuations observed in <strong>the</strong> full-<br />

scale core madel used for flow studies,<br />

The results of a study- of <strong>the</strong> temperature<br />

structure in an idealized ART core were presented<br />

in <strong>the</strong> previous report.8 The increase in <strong>the</strong><br />

'H. F. Poppandiek and L. D. Palmer, ANP Quur.<br />

Prog. Rep. March 10, 1956. p 176.<br />

HELICAL Re = 256,000<br />

6wucF<br />

<strong>ORNL</strong>-LR-DWG 44742<br />

W=s (UNIFORM)<br />

At, = TOTAL CHANGE IN WALL TEMPERATURE<br />

At,,, = AXIAL FLUID TEMPERATURE RISE IN<br />

GOING THROUGH CORE<br />

Fig. 4.1.10. Transient Surface and Fluid Temperatures Obtained for ART Core Model with a Uniform 7<br />

Volume Heat Source.<br />

2 26<br />