ANP PROJECT PROGRESS REPORT<br />

<strong>the</strong> effect of time on <strong>the</strong> extent of decarburization<br />

of <strong>the</strong> steel specimens.<br />

Two AIS1 1043 steel specimens and sodium were<br />

loaded into evacuated Armco iron and type 304<br />

ELC stainless steel containers and tested at<br />

183O0F for 400 hr. The conditions and results<br />

of <strong>the</strong> tests are given in Table 3.2.6. As expected<br />

on <strong>the</strong> basis of <strong>the</strong> previous investigation, exten-<br />

sive decarburization of <strong>the</strong> steel specimens oc-<br />

13<br />

curred in both <strong>the</strong> iron and <strong>the</strong> stainless steel<br />

containers. The extent of decarburization of <strong>the</strong> i<br />

AIS1 1043 steel specimens was greater in <strong>the</strong>se<br />

400-hr tests than in <strong>the</strong> previous 100-hr test,<br />

and, in addition, <strong>the</strong> vapor zone of <strong>the</strong> stainless<br />

steel container was carburized in <strong>the</strong> 400-hr test<br />

and not in <strong>the</strong> 100-hr test. This discrepancy may<br />

be due to <strong>the</strong> vapor zone sample having been taken<br />

closer to <strong>the</strong> bath zone after <strong>the</strong> 400-hr test than<br />

TABLE 826. CARBON AND NICKEL ANALYSES OF THE VARIOUS COMPONENTS OF SYSTEMS DESIGNED<br />

FOR STUDYING THE DECARBURIZATION OF MILD STEEL BY SODIUM<br />

Test System<br />

AIS1 1043 steel specimen in Steel specimen<br />

Armco iron container<br />

As received<br />

AIS1 1043 steel specimen in<br />

type 304 ELC stainless<br />

steel container<br />

*Sample taken 4 in. above bath level.<br />

**Sample taken 1 in. above bath level.<br />

154<br />

Weight Loss in<br />

Carbon Content Nickel Content<br />

Material Analyzed 400-hr Test<br />

(wt 96) (w 16)<br />

2<br />

(din. 1<br />

After 100-hr test<br />

After 400-hr test<br />

Iron container<br />

As received<br />

Vapor zone<br />

After 100-hr test<br />

After 400-hr test<br />

Bath zone<br />

After 100-hr test<br />

After 400-hr test<br />

Steel specimen<br />

As received<br />

After 100-hr test<br />

After 400-hr test<br />

Steel container<br />

As received<br />

Vapor zone<br />

After 100-hr test<br />

After 400-hr test<br />

Bath zone<br />

After 100-hr test<br />

After 400-hr test<br />

0.433<br />

0.121<br />

0.054<br />

0.018<br />

0.019<br />

0.016<br />

0.035<br />

0.024<br />

0.433<br />

0.100<br />

0.074<br />

0.008<br />

0.008<br />

0.090<br />

0.037 11.12<br />

0.022f<br />

0.162** 10.32<br />

0.128<br />

0.200<br />

9.98<br />

0.0001<br />

0.0408<br />

0.0002<br />

0.0303<br />

*<br />

'W