05.08.2013 Views

Pressure limiter for multiple actuators ÜB…A2 NB…A2

Pressure limiter for multiple actuators ÜB…A2 NB…A2

Pressure limiter for multiple actuators ÜB…A2 NB…A2

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NB...A2 / <strong>ÜB…A2</strong> mounting options<br />

FRI gas pressure regulator<br />

<strong>Pressure</strong> tap<br />

1<br />

2<br />

3<br />

NB...A2 / <strong>ÜB…A2</strong><br />

mounting possible…<br />

yes<br />

yes<br />

yes<br />

NB...A2 / <strong>ÜB…A2</strong> mounting options<br />

MB 053-403 GasMultiBloc<br />

<strong>Pressure</strong> tap<br />

1<br />

2<br />

3<br />

4<br />

NB...A2 / <strong>ÜB…A2</strong> mounting options<br />

MB-D GasMultiBloc; MB-Z 405-412<br />

<strong>Pressure</strong> tap<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

NB...A2 / <strong>ÜB…A2</strong><br />

mounting possible…<br />

yes, with # 221 630<br />

yes<br />

yes<br />

yes, with # 221 630<br />

NB...A2 / <strong>ÜB…A2</strong><br />

mounting possible…<br />

alternatively to 7<br />

no<br />

yes<br />

yes<br />

yes, with # 214 975<br />

yes, with # 221 630<br />

yes<br />

NB...A2 / <strong>ÜB…A2</strong> mounting options<br />

Safety solenoid valve<br />

SV-… 505-520<br />

<strong>Pressure</strong> tap NB...A2 / <strong>ÜB…A2</strong><br />

mounting possible…<br />

1<br />

2<br />

3<br />

4<br />

SV<br />

505/507<br />

pe<br />

no<br />

no<br />

pa with<br />

221 630<br />

horizontal<br />

SV<br />

510/512<br />

pa<br />

pe<br />

pe 1,(2)<br />

pa 2)<br />

SV<br />

520<br />

pa<br />

pe<br />

pe 1)<br />

pa<br />

1,2,3 seal plug G 1/8 as per<br />

DIN ISO 228<br />

1 2 3<br />

6<br />

5 3 4<br />

➞<br />

➞<br />

4<br />

7<br />

1<br />

2<br />

p = 500 mbar<br />

max.<br />

FRI<br />

3 2 1<br />

6 7<br />

1<br />

6<br />

2<br />

➞<br />

5 3 4 43<br />

5<br />

<strong>Pressure</strong> tap 3<br />

➞<br />

435 2<br />

6<br />

1<br />

1<br />

1<br />

3<br />

The seal plugs 1 can also be<br />

replaced by an instrument<br />

gland<br />

2 p e<br />

2 p e<br />

3 p a<br />

3 p a<br />

1,3 seal plug G 1/8<br />

2 Instrument gland, optional<br />

4 Instrument gland<br />

2<br />

7<br />

3<br />

p e<br />

2 3<br />

p e<br />

4<br />

p a<br />

4<br />

p a<br />

5<br />

p Br<br />

1 6<br />

2<br />

7<br />

3<br />

p e<br />

2 3<br />

p e<br />

4<br />

p a<br />

4<br />

p a<br />

5<br />

p Br<br />

5<br />

p Br<br />

5<br />

p Br<br />

1,3,4 seal plug G 1/8<br />

2,6 Instrument gland, optional G 1/8<br />

5 M4 inner hex<br />

<strong>Pressure</strong> tap 4<br />

<strong>Pressure</strong> tap 1<br />

<strong>Pressure</strong> tap 2<br />

<strong>Pressure</strong> taps <strong>for</strong> 1, 2 and 4 are installed depending on<br />

the SV model.<br />

1) Not with appliance connector model<br />

2) For pressure switch assembly, pay attention to the<br />

flange attachment<br />

4<br />

4 … 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!