driveraccelerator Figure5.21:ExperimentalsetuptomeasurebunchlengthwithzerophasingmethodintheIR-FEL<br />

Cavities tuned off<br />

24 MeV dipole<br />

Quadrupole<br />

OTR<br />

To ER dump<br />

12<br />

10<br />

0.036 mm<br />

2 cavities -90 deg (SC OFF)<br />

2 cavities -90 deg (SC ON)<br />

2 cavities +90 deg (SC OFF)<br />

4<br />

8 2 cavities +90 deg (SC ON)<br />

Figure5.22:Horizontalbeamenvelopeevolutionfromtheexitofthefourcavitiesinthecryomodule<br />

3 cavities -90 deg (SC OFF)<br />

4 3<br />

3 cavities -90 deg (SC ON)<br />

uptothebeamprolestationinthespectrometertransportlinefordierentnumbersofzerophasing<br />

3 cavities +90 deg (SC OFF)<br />

3<br />

3 cavities +90 deg (SC ON)<br />

6<br />

cavities.Foreachcase,thespacechargeroutineinparmelaisturnedon<strong>and</strong>o.<br />

4 cavities -90 deg (SC OFF)<br />

2<br />

4 cavities -90 deg (SC ON)<br />

4 cavities +90 deg (SC OFF)<br />

2<br />

4 cavities +90 deg (SC ON)<br />

4<br />

1<br />

1<br />

2<br />

All cavity off<br />

0<br />

1600 1800 2000 2200 2400 2600<br />

Distance (cm)<br />

x (mm)<br />

cavities off (SC OFF)<br />

cavities off (SC ON)<br />

1 cavity -90 deg (SC OFF)<br />

1 cavity -90 deg (SC ON)<br />

1 cavity +90 deg (SC OFF)<br />

1 cavity +90 deg (SC ON)