Durable and cost effective single patient use SpO 2 <strong>sensors</strong><br />
<strong>Philips</strong> family of single-patient use SpO2 <strong>sensors</strong> provides continuous, non-invasive<br />
measurement of arterial oxygen saturation.<br />
You can choose between our Adult-Pediatric<br />
sensor to measure a wide range of patients or<br />
our wrap <strong>sensors</strong> <strong>that</strong> are optimally designed<br />
for the infant or neonate.<br />
In addition, these <strong>sensors</strong> are optimized for<br />
<strong>Philips</strong> FAST-SpO technology, providing you<br />
2<br />
additional benefits such as reduced sensitivity<br />
to patient movement and other artifacts.<br />
When your goal is superb patient care,<br />
there’s no better choice than <strong>Philips</strong>.<br />
<strong>Philips</strong> family of disposable <strong>sensors</strong><br />
• Cost-effective. <strong>Philips</strong> <strong>Disposable</strong>s offer a<br />
cost-effective solution and when combined<br />
with reusable <strong>sensors</strong>, can help to lower<br />
your total cost of SpO monitoring.<br />
2<br />
• Quality. <strong>Philips</strong> meets a wide range of<br />
standards <strong>that</strong> have been set by regulatory<br />
authorities and standardization committees<br />
(e.g. FDA, IEC, ISO), plus <strong>Philips</strong> own<br />
internal standards to achieve high levels of<br />
quality and safety.<br />
• Compatible. Tested and qualified<br />
for <strong>Philips</strong>, legacy HP and Agilent, and<br />
validated Nellcor ® and GE monitors.<br />
• Convenient. 20 <strong>sensors</strong> per box.
Three <strong>sensors</strong> for a wide range of patient sizes<br />
M1131A (Adult/Pediatric)<br />
• Versatile. One sensor fits pediatric to<br />
large adult patients.<br />
• Simple to use. Light ergonomically<br />
shaped sensor slips easily onto a patient’s<br />
finger and is easy to reposition as needed.<br />
• Reliable. Pre-aligned LED sensor provides<br />
fast, reliable readings you can count on to<br />
make informed clinical decisions.<br />
• Long <strong>last</strong>ing. Designed to perform for<br />
a single patient’s average hospital stay.<br />
M1132A and M1133A<br />
(Infant and Neonate)<br />
• Comfortable. Minimal adhesive is<br />
optimized to reduce irritation when<br />
skin sensitivity is a concern.<br />
• Accurate. Sensor design prevents ambient<br />
light for reliable readings.<br />
• Durable and cost effective.<br />
Ruggedly designed to out<strong>last</strong> typical adhesive<br />
<strong>sensors</strong>.<br />
© 2008 Koninklijke <strong>Philips</strong> Electronics N.V.<br />
All rights are reserved.<br />
M1131A (Adult/Pediatric Sensor)<br />
• Patient size: greater than 20kg (44 lb)<br />
• Application: any finger (except thumb)<br />
M1132A (Infant Sensor)<br />
• Patient size: 3-10kg (6.6-22 lb)<br />
• Application: any finger or toe<br />
M1133A (Neonatal/Infant/Adult<br />
Sensor)<br />
• Patient size: 40kg (>88 lb)<br />
Application: finger<br />
* Pulse oximetry measurements are statistically distributed. Two-thirds of all pulse oximetry measurements can be expected to fall within the stated accuracy.<br />
When <strong>sensors</strong> are used on neonatal subjects as recommended, the literature predicts the accuracy range should be increased by +/-1% to account for affect<br />
on oximeter measurements due to fetal hemoglobin in neonatal blood.<br />
<strong>Philips</strong> Medical Systems Nederland B.V. reserves the right to make changes<br />
in specifications and/or to discontinue any product at any time without<br />
notice or obligation and will not be liable for any consequences resulting<br />
from the use of this publication.<br />
<strong>Philips</strong> Healthcare is part of Royal <strong>Philips</strong> Electronics<br />
www.medical.philips.com<br />
medical@philips.com<br />
fax: +31 40 27 64 887<br />
Specifications<br />
Physical<br />
M1131A:<br />
Cable length: 45.0 cm (18”)<br />
M1132A, M1133A:<br />
Cable length: 90.0 cm (35”)<br />
Temperature range<br />
Operating: 10 to 37°C<br />
(50 to 98.6°F)<br />
Humidity<br />
Operating: 95% RH max at<br />
37°C (98.6°F)<br />
SpO 2 accuracy*<br />
Accuracy with compatible<br />
<strong>Philips</strong> (Agilent/Hewlett-Packard)<br />
and Nellcor monitors: (N-200,<br />
N-395, N3000 N-20 PA, NPB-40)<br />
and GE Dinamap Pro 400V1.<br />
M1131A:<br />
RMS = ±3% (70 to 100%)<br />
M1132A, M1133A:<br />
RMS = ±2% (70 to 100%)<br />