DICOM Conformance Statement - InCenter - Philips
DICOM Conformance Statement - InCenter - Philips
DICOM Conformance Statement - InCenter - Philips
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
8. ANNEXES VERADIUS AE<br />
8.1. IOD Contents<br />
<strong>DICOM</strong> <strong>Conformance</strong> <strong>Statement</strong> Page 59 of 82<br />
8.1.1. Created SOP Instances<br />
This section specifies each IOD created by the Veradius AE.<br />
Defined abbreviations for the presence of IOD modules are:<br />
ALWAYS the module is always present<br />
CONDITIONAL the module is used under specified condition<br />
Defined abbreviations for the presence of module attributes in the tables are:<br />
ALWAYS the attribute is always present with a value<br />
EMPTY the attribute is always present without any value (attribute sent zero<br />
length)<br />
VNAP the attribute is always present and its Value is Not Always Present<br />
(attribute sent zero length if no value is present)<br />
ANAP the attribute is present under specified condition – if present then it<br />
will always have a value<br />
ANAPCV the attribute is present under specified condition – if present then<br />
its Value is Not Always Present (attribute sent zero length if<br />
condition applies and no value is present)<br />
ANAPEV the attribute is present under specified condition – if present then it<br />
will not have any value<br />
Defined abbreviations for the source of the attribute data values in the tables are:<br />
AUTO the attribute value is generated automatically<br />
CONFIG the attribute value source is a configurable parameter<br />
COPY the attribute value source is another SOP instance<br />
FIXED the attribute value is hard-coded in the application<br />
IMPLICIT the attribute value source is a user-implicit setting<br />
MPPS the attribute value source is a Modality Performed Procedure Step<br />
MWL the attribute value source is a Modality Worklist<br />
USER the attribute value source is explicit user input<br />
8.1.1.1. Secondary Capture Image Storage SOP Class<br />
Table 67: Modules of the Secondary Capture Image Storage SOP Class<br />
Information Entity Module Name Usage<br />
Patient Patient module ALWAYS<br />
Study<br />
General Study module ALWAYS<br />
Patient Study module CONDITIONAL<br />
Series General Series module ALWAYS<br />
Equipment<br />
General Equipment module CONDITIONAL<br />
SC Equipment module ALWAYS<br />
Image<br />
General Image module ALWAYS<br />
Image Pixel module ALWAYS<br />
SC Image module ALWAYS<br />
© Koninklijke <strong>Philips</strong> Electronics N.V. 2009<br />
XPS031-090132.02 Veradius R1.1 6 Jul 2009