DICOM Conformance Statement Page 52 of 82 Abstract Syntax Transfer Syntax Name UID Name List UID List Secondary Capture Image Storage 1.2.840.10008.5.1.4.1.1.7 Grayscale Softcopy Presentation State Storage 1.2.840.10008.5.1.4.1.1.11.1 X-Ray Angiographic Image Storage 1.2.840.10008.5.1.4.1.1.12.1 X-Ray Radiofluoroscopic Image Storage 1.2.840.10008.5.1.4.1.1.12.2 X-Ray Specialization 1.3.46.670589.2.3.1.1 Stack of X-Ray 1.3.46.670589.2.4.1.1 Volume 1.3.46.670589.5.0.1.1 3D Volume Object 1.3.46.670589.5.0.2.1 Surface 1.3.46.670589.5.0.3.1 Cardio 1.3.46.670589.5.0.8.1 CT Synthetic Image 1.3.46.670589.5.0.9 MR Synthetic Image 1.3.46.670589.5.0.10 MR Cardio Analysis 1.3.46.670589.5.0.11.1 CX Synthetic Image 1.3.46.670589.5.0.12 Perfusion 1.3.46.670589.5.0.13 Perfusion Analysis 1.3.46.670589.5.0.14 5.2.1.1. File Meta Information for the VF Workstation AE The Source Application Entity Title is configurable (ref. section 5.4). 5.2.1.2. Real-World Activities 5.2.1.2.1. Display Directory When a Database Open action is initiated on DICOM media then the VF Workstation AE acts as an FSR using the interchange option to read the DICOMDIR of the DICOM media. This will result in an overview of the patients, studies, series, and images on the GUI. 5.2.1.2.1.1. Media Storage Application Profile As depicted in Table 61, the VF Workstation AE supports the RWA Display Directory for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application profiles. 5.2.1.2.1.1.1. Options The mandatory DICOMDIR keys are required for the correct display of directory information. The display is structured according the DICOM Composite Information Model: Patient, Study, Series, and Image. 5.2.1.2.2. Read Image When an image transfer from DICOM media is initiated then the VF Workstation AE acts as an FSR using the interchange option to import SOP instances from the DICOM media. © Koninklijke Philips Electronics N.V. 2009 XPS031-090132.02 Veradius R1.1 6 Jul 2009
DICOM Conformance Statement Page 53 of 82 5.2.1.2.2.1. Media Storage Application Profile As depicted in Table 61, the VF Workstation AE supports the RWA Read Image for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application profiles. 5.2.1.2.2.1.1. Options The mandatory attributes of the DICOM images are required for the correct storage of the images in the local database. Optional attributes and retired/private attributes are stored too – if present; this is equivalent with the level 2 (Full) conformance for the Storage service class in the Network support. 5.2.1.2.3. Write Image When an image transfer to DICOM media is initiated then the VF Workstation AE acts as an FSC using the interchange option to write SOP instances on the DICOM media. 5.2.1.2.3.1. Media Storage Application Profile As depicted in Table 61, the VF Workstation AE supports the RWA Write Image for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application profiles. However, the VF Workstation AE only supports writing on DVD+R(W) media, not DVD-R(W) media. 5.2.1.2.3.1.1. Options The DICOMDIR file will be extended when new images are written. In case some attributes are not present in an image but are specified as mandatory in the DICOMDIR definition of DICOM media, a generated value will be filled in. Implementation remarks an restrictions When writing the DICOMDIR records, key values are generated when no value of the corresponding attribute is supplied, according to the following table. Table 63: Generated Keys Key Tag Generated Value Patient Keys Patient ID 0010,0020 At import the VF Workstation AE each time creates a new value based on the Study Instance UID for each new study written to DICOM media (even if this study belongs to a patient recorded earlier). Otherwise the default generated value shall be a succession of “UNKNOWN”, the Patient’s Name, the Patient’s Birth Date, and the Patient’s Sex, concatenated by using underscore characters. Study Keys Study Date 0008,0020 Current date. Study Time 0008,0030 Current time. Study ID 0020,0010 “UNKNOWN” Series Number 0020,0011 1 Instance Number 0020,0013 1 Series Keys Image Keys The default value for (0028,1040) Pixel Intensity Relationship is set to DISP. The VF Workstation AE can write volumes of the media to that media. If spanning is required then the VF Workstation AE asks for a new media. © Koninklijke Philips Electronics N.V. 2009 XPS031-090132.02 Veradius R1.1 6 Jul 2009
- Page 1 and 2: © Koninklijke Philips Electronics
- Page 3 and 4: DICOM Conformance Statement Page 3
- Page 5 and 6: DICOM Conformance Statement Page 5
- Page 7 and 8: 2. TABLE OF CONTENTS DICOM Conforma
- Page 9 and 10: 3. INTRODUCTION 3.1. Revision Histo
- Page 11 and 12: DICOM Conformance Statement Page 11
- Page 13 and 14: DICOM Conformance Statement Page 13
- Page 15 and 16: DICOM Conformance Statement Page 15
- Page 17 and 18: DICOM Conformance Statement Page 17
- Page 19 and 20: 4.2.1.3.2. Get Worklist DICOM Confo
- Page 21 and 22: DICOM Conformance Statement Page 21
- Page 23 and 24: 4.2.1.3.3. Export DICOM Conformance
- Page 25 and 26: DICOM Conformance Statement Page 25
- Page 27 and 28: DICOM Conformance Statement Page 27
- Page 29 and 30: DICOM Conformance Statement Page 29
- Page 31 and 32: DICOM Conformance Statement Page 31
- Page 33 and 34: 4.2.1.4. Association Acceptance Pol
- Page 35 and 36: 4.2.2. VF Workstation AE DICOM Conf
- Page 37 and 38: DICOM Conformance Statement Page 37
- Page 39 and 40: Query Level Series Image DICOM Conf
- Page 41 and 42: DICOM Conformance Statement Page 41
- Page 43 and 44: 4.3. AE Specifications DICOM Confor
- Page 45 and 46: DICOM Conformance Statement Page 45
- Page 47 and 48: 5. MEDIA INTERCHANGE 5.1. Implement
- Page 49 and 50: DICOM Conformance Statement Page 49
- Page 51: 5.2. AE Specifications DICOM Confor
- Page 55 and 56: DICOM Conformance Statement Page 55
- Page 57 and 58: 7. SECURITY 7.1. Security Profiles
- Page 59 and 60: 8. ANNEXES VERADIUS AE 8.1. IOD Con
- Page 61 and 62: DICOM Conformance Statement Page 61
- Page 63 and 64: DICOM Conformance Statement Page 63
- Page 65 and 66: DICOM Conformance Statement Page 65
- Page 67 and 68: DICOM Conformance Statement Page 67
- Page 69 and 70: DICOM Conformance Statement Page 69
- Page 71 and 72: DICOM Conformance Statement Page 71
- Page 73 and 74: DICOM Conformance Statement Page 73
- Page 75 and 76: DICOM Conformance Statement Page 75
- Page 77 and 78: DICOM Conformance Statement Page 77
- Page 79 and 80: DICOM Conformance Statement Page 79
- Page 81 and 82: DICOM Conformance Statement Page 81
<strong>DICOM</strong> <strong>Conformance</strong> <strong>Statement</strong> Page 52 of 82<br />
Abstract Syntax Transfer Syntax<br />
Name UID Name List UID List<br />
Secondary Capture Image Storage 1.2.840.10008.5.1.4.1.1.7<br />
Grayscale Softcopy Presentation<br />
State Storage<br />
1.2.840.10008.5.1.4.1.1.11.1<br />
X-Ray Angiographic Image Storage 1.2.840.10008.5.1.4.1.1.12.1<br />
X-Ray Radiofluoroscopic Image<br />
Storage<br />
1.2.840.10008.5.1.4.1.1.12.2<br />
X-Ray Specialization 1.3.46.670589.2.3.1.1<br />
Stack of X-Ray 1.3.46.670589.2.4.1.1<br />
Volume 1.3.46.670589.5.0.1.1<br />
3D Volume Object 1.3.46.670589.5.0.2.1<br />
Surface 1.3.46.670589.5.0.3.1<br />
Cardio 1.3.46.670589.5.0.8.1<br />
CT Synthetic Image 1.3.46.670589.5.0.9<br />
MR Synthetic Image 1.3.46.670589.5.0.10<br />
MR Cardio Analysis 1.3.46.670589.5.0.11.1<br />
CX Synthetic Image 1.3.46.670589.5.0.12<br />
Perfusion 1.3.46.670589.5.0.13<br />
Perfusion Analysis 1.3.46.670589.5.0.14<br />
5.2.1.1. File Meta Information for the VF Workstation AE<br />
The Source Application Entity Title is configurable (ref. section 5.4).<br />
5.2.1.2. Real-World Activities<br />
5.2.1.2.1. Display Directory<br />
When a Database Open action is initiated on <strong>DICOM</strong> media then the VF Workstation<br />
AE acts as an FSR using the interchange option to read the <strong>DICOM</strong>DIR of the <strong>DICOM</strong><br />
media.<br />
This will result in an overview of the patients, studies, series, and images on the GUI.<br />
5.2.1.2.1.1. Media Storage Application Profile<br />
As depicted in Table 61, the VF Workstation AE supports the RWA Display Directory<br />
for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application<br />
profiles.<br />
5.2.1.2.1.1.1. Options<br />
The mandatory <strong>DICOM</strong>DIR keys are required for the correct display of directory<br />
information. The display is structured according the <strong>DICOM</strong> Composite Information<br />
Model: Patient, Study, Series, and Image.<br />
5.2.1.2.2. Read Image<br />
When an image transfer from <strong>DICOM</strong> media is initiated then the VF Workstation AE<br />
acts as an FSR using the interchange option to import SOP instances from the<br />
<strong>DICOM</strong> media.<br />
© Koninklijke <strong>Philips</strong> Electronics N.V. 2009<br />
XPS031-090132.02 Veradius R1.1 6 Jul 2009