DICOM Conformance Statement - InCenter - Philips

DICOM Conformance Statement - InCenter - Philips DICOM Conformance Statement - InCenter - Philips

incenter.medical.philips.com
from incenter.medical.philips.com More from this publisher
03.08.2013 Views

DICOM Conformance Statement Page 52 of 82 Abstract Syntax Transfer Syntax Name UID Name List UID List Secondary Capture Image Storage 1.2.840.10008.5.1.4.1.1.7 Grayscale Softcopy Presentation State Storage 1.2.840.10008.5.1.4.1.1.11.1 X-Ray Angiographic Image Storage 1.2.840.10008.5.1.4.1.1.12.1 X-Ray Radiofluoroscopic Image Storage 1.2.840.10008.5.1.4.1.1.12.2 X-Ray Specialization 1.3.46.670589.2.3.1.1 Stack of X-Ray 1.3.46.670589.2.4.1.1 Volume 1.3.46.670589.5.0.1.1 3D Volume Object 1.3.46.670589.5.0.2.1 Surface 1.3.46.670589.5.0.3.1 Cardio 1.3.46.670589.5.0.8.1 CT Synthetic Image 1.3.46.670589.5.0.9 MR Synthetic Image 1.3.46.670589.5.0.10 MR Cardio Analysis 1.3.46.670589.5.0.11.1 CX Synthetic Image 1.3.46.670589.5.0.12 Perfusion 1.3.46.670589.5.0.13 Perfusion Analysis 1.3.46.670589.5.0.14 5.2.1.1. File Meta Information for the VF Workstation AE The Source Application Entity Title is configurable (ref. section 5.4). 5.2.1.2. Real-World Activities 5.2.1.2.1. Display Directory When a Database Open action is initiated on DICOM media then the VF Workstation AE acts as an FSR using the interchange option to read the DICOMDIR of the DICOM media. This will result in an overview of the patients, studies, series, and images on the GUI. 5.2.1.2.1.1. Media Storage Application Profile As depicted in Table 61, the VF Workstation AE supports the RWA Display Directory for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application profiles. 5.2.1.2.1.1.1. Options The mandatory DICOMDIR keys are required for the correct display of directory information. The display is structured according the DICOM Composite Information Model: Patient, Study, Series, and Image. 5.2.1.2.2. Read Image When an image transfer from DICOM media is initiated then the VF Workstation AE acts as an FSR using the interchange option to import SOP instances from the DICOM media. © Koninklijke Philips Electronics N.V. 2009 XPS031-090132.02 Veradius R1.1 6 Jul 2009

DICOM Conformance Statement Page 53 of 82 5.2.1.2.2.1. Media Storage Application Profile As depicted in Table 61, the VF Workstation AE supports the RWA Read Image for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application profiles. 5.2.1.2.2.1.1. Options The mandatory attributes of the DICOM images are required for the correct storage of the images in the local database. Optional attributes and retired/private attributes are stored too – if present; this is equivalent with the level 2 (Full) conformance for the Storage service class in the Network support. 5.2.1.2.3. Write Image When an image transfer to DICOM media is initiated then the VF Workstation AE acts as an FSC using the interchange option to write SOP instances on the DICOM media. 5.2.1.2.3.1. Media Storage Application Profile As depicted in Table 61, the VF Workstation AE supports the RWA Write Image for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application profiles. However, the VF Workstation AE only supports writing on DVD+R(W) media, not DVD-R(W) media. 5.2.1.2.3.1.1. Options The DICOMDIR file will be extended when new images are written. In case some attributes are not present in an image but are specified as mandatory in the DICOMDIR definition of DICOM media, a generated value will be filled in. Implementation remarks an restrictions When writing the DICOMDIR records, key values are generated when no value of the corresponding attribute is supplied, according to the following table. Table 63: Generated Keys Key Tag Generated Value Patient Keys Patient ID 0010,0020 At import the VF Workstation AE each time creates a new value based on the Study Instance UID for each new study written to DICOM media (even if this study belongs to a patient recorded earlier). Otherwise the default generated value shall be a succession of “UNKNOWN”, the Patient’s Name, the Patient’s Birth Date, and the Patient’s Sex, concatenated by using underscore characters. Study Keys Study Date 0008,0020 Current date. Study Time 0008,0030 Current time. Study ID 0020,0010 “UNKNOWN” Series Number 0020,0011 1 Instance Number 0020,0013 1 Series Keys Image Keys The default value for (0028,1040) Pixel Intensity Relationship is set to DISP. The VF Workstation AE can write volumes of the media to that media. If spanning is required then the VF Workstation AE asks for a new media. © Koninklijke Philips Electronics N.V. 2009 XPS031-090132.02 Veradius R1.1 6 Jul 2009

<strong>DICOM</strong> <strong>Conformance</strong> <strong>Statement</strong> Page 52 of 82<br />

Abstract Syntax Transfer Syntax<br />

Name UID Name List UID List<br />

Secondary Capture Image Storage 1.2.840.10008.5.1.4.1.1.7<br />

Grayscale Softcopy Presentation<br />

State Storage<br />

1.2.840.10008.5.1.4.1.1.11.1<br />

X-Ray Angiographic Image Storage 1.2.840.10008.5.1.4.1.1.12.1<br />

X-Ray Radiofluoroscopic Image<br />

Storage<br />

1.2.840.10008.5.1.4.1.1.12.2<br />

X-Ray Specialization 1.3.46.670589.2.3.1.1<br />

Stack of X-Ray 1.3.46.670589.2.4.1.1<br />

Volume 1.3.46.670589.5.0.1.1<br />

3D Volume Object 1.3.46.670589.5.0.2.1<br />

Surface 1.3.46.670589.5.0.3.1<br />

Cardio 1.3.46.670589.5.0.8.1<br />

CT Synthetic Image 1.3.46.670589.5.0.9<br />

MR Synthetic Image 1.3.46.670589.5.0.10<br />

MR Cardio Analysis 1.3.46.670589.5.0.11.1<br />

CX Synthetic Image 1.3.46.670589.5.0.12<br />

Perfusion 1.3.46.670589.5.0.13<br />

Perfusion Analysis 1.3.46.670589.5.0.14<br />

5.2.1.1. File Meta Information for the VF Workstation AE<br />

The Source Application Entity Title is configurable (ref. section 5.4).<br />

5.2.1.2. Real-World Activities<br />

5.2.1.2.1. Display Directory<br />

When a Database Open action is initiated on <strong>DICOM</strong> media then the VF Workstation<br />

AE acts as an FSR using the interchange option to read the <strong>DICOM</strong>DIR of the <strong>DICOM</strong><br />

media.<br />

This will result in an overview of the patients, studies, series, and images on the GUI.<br />

5.2.1.2.1.1. Media Storage Application Profile<br />

As depicted in Table 61, the VF Workstation AE supports the RWA Display Directory<br />

for STD-GEN-CD, STD-GEN-USB-JPEG and STD-GEN-DVD-JPEG application<br />

profiles.<br />

5.2.1.2.1.1.1. Options<br />

The mandatory <strong>DICOM</strong>DIR keys are required for the correct display of directory<br />

information. The display is structured according the <strong>DICOM</strong> Composite Information<br />

Model: Patient, Study, Series, and Image.<br />

5.2.1.2.2. Read Image<br />

When an image transfer from <strong>DICOM</strong> media is initiated then the VF Workstation AE<br />

acts as an FSR using the interchange option to import SOP instances from the<br />

<strong>DICOM</strong> media.<br />

© Koninklijke <strong>Philips</strong> Electronics N.V. 2009<br />

XPS031-090132.02 Veradius R1.1 6 Jul 2009