Ringfeder® Locking Elements RfN 8006 / Type GSA<br />
3 Tighten the lo cking scr ews evenly and in s everal steps foll owing the<br />
diamet rically opposite sequence illustrated i Figure n 1: Tightening Sequence.<br />
a Tighten the scr ews by hand until a slight positi ve contact is esta blished .<br />
Make final alignment adjustments to the connection.<br />
b Tighten the scr ews to appr ox. one-half the specified torque using an<br />
extended key or torque wrench.<br />
c Tighten the scr ews to full tightening torque using a torque wrench.<br />
d Verify that the scr ews are fully tightened by applying the specified torqu e.<br />
4 Check distance x . The clamp ring should not ma ke contact with the face of the<br />
hub. The gap between the clamp ring and hub face should be even all the way<br />
around.<br />
REMOVAL<br />
Note: Ring feder ® locking elements are not self-lo cking.<br />
1 Remove any accumulated contaminants from the connection.<br />
2 Loosen the lo cking scr ews in s everal stages foll owing a diamet rically opposite<br />
sequenc e.<br />
3 Remove the hub and lo cking elements from the shaft . If the lo cking element is<br />
jammed, loosen it by tapping it with a light hamme r.<br />