However, from the results of the batch experiments conducted this does not<br />

seem to happen in any of the ECs examined. This was probably due to the<br />

microbiological activity, particularly in the fourth batch experiment, where the<br />

columns A and B reached breakthrough limits earlier compared to the third batch<br />

experiment, but not columns C and D. Microbiological activity was also observed<br />

earlier in the fourth batch experiment, compared to the second and third batch<br />

experiment. This also seems to have affected the results from the fourth batch<br />

experiment, resulting in decreased correlation of GAC bed depth and column service<br />

time compared to the third batch experiment.<br />

Furthermore, the difference of the linear flow rate between the forth batch<br />

experiment and the second and third batch experiments is probably not statistically<br />

significant and so the changes of the values of the constants N0 and K are not<br />

statistically significant either. So, for the reasons aforementioned the results were<br />

assumed to be of a single linear flow rate (the average value of 3,39 m/h) and the<br />

values of the constants N0 and K were extracted from all batch experiments for each<br />

EC examined. Table 1 shows the final values of the constants N0 and K for each EC<br />

examined. Those constants are referred to a single linear flow rate (3,39 m/h).<br />

Table 1 : Final values of the constants N0 and K at 3,39 m/h for each EC examined.<br />

Emerging contaminant N0 {g/m 3 } K {m 3 /(g·h)} Breakthrough limit<br />

Bisphenol-A 12,82 7,48 10%<br />

Triclosan 8,41 19,69 7,5%<br />

Ibuprofen 8,89 15,99 20%<br />

Naproxen 9,14 25,88 20%<br />

Ketoprofen 9,46 15,18 20%<br />

Diclofenac 10,85 12,86 20%<br />

In the design of a GAC column unit in a typical water treatment plant in order<br />

to remove from water one of the ECs examined (Diclofenac) it seems that the surface<br />

needed is relatively large (551 m 2 ) probably due to the fact that the flow rate of the<br />

unit is very small compared to the flow rate of the plant. So, it is suggested the<br />

redesign of the unit with bigger flow rates and new constants N0 and K respectively.<br />