Initially two solutions of the ECs were made in methanol as solvent (solution<br />

A & B, from solution A came solution B) to achieve concentrations at environmental<br />

levels. The solution used (solution B) had approximately 10 mg/L of the ECs studied.<br />

The final solution was made with measured volume from solution B and tap water<br />

from the lab (NTUA groundwater) so that the ECs were up to 1 or 2 μg/L. The final<br />

solution was kept in a 200 L plastic bottle from HDPE, while solutions A & B were<br />

kept in the refrigerator at -18 o C.<br />

The pilot-scale system used four columns made from Plexiglas, which were<br />

working down-flow under pressure. Each column was 5 cm diameter and 1,40 m<br />

height. In the bottom of each column special valves were installed for sampling<br />

(Figure 1). As sorbent material the Granular Activated Carbon Filtracarb CC60 was<br />

used, bought from CHEMiTEC. Before each installation, GAC was put for one day in<br />

furnace at 106 o C for drying.<br />

At the bottom of each column were put 4 to 5 pieces of glaswolle to retain<br />

GAC inside the column. The solvent was added to the system through a peristaltic<br />

pump. From the bottom of each column and the 200 L bottle samples were taken at a<br />

regular basis (3 or 4 times per week) at 100 mL volumetric flasks for further analysis.<br />

The analytical method used (Samaras et al., 2011) included four stages :<br />

acidisation with HCl to pH 2,5-3, solid phase extraction (Isollute C18 columns were<br />

used from Biotage, installed in a proper aparatus – see Figure 2), derivatization<br />

(Pyridine and a solution of BSTFA and TMCS were used) and analysis on GC/MS<br />

(bought from Agilent Technologies).<br />

Figure 1 : The pilot-scale GAC column system used.<br />