TECHNICAL SPECIFICATION<br />
SENSOR<br />
DRÄGER<br />
S<strong>en</strong>sor + Article number<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 1(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Gas measuring s<strong>en</strong>sor<br />
Calibration interval:<br />
Minimum 1 day<br />
Default 6 months<br />
Maximum 12 months<br />
Temperature:<br />
Operating: - 40°C to 65°C<br />
Storage: 0°C to 40°C<br />
Working pressure:<br />
7<strong>00</strong>mbar to 13<strong>00</strong>mbar<br />
Type: NO2<br />
Ref.: 6809655<br />
Measuring range:<br />
Minimum: 5 ppm<br />
Default: 10 ppm<br />
Maximum: 1<strong>00</strong> ppm<br />
Expected s<strong>en</strong>sor life: > 18 months<br />
Lower detection limit: 0.3 ppm<br />
Including reaction filter CF<br />
Type: NO<br />
Ref.: 6809625<br />
Measuring range:<br />
Minimum: 30 ppm<br />
Default: 50 ppm<br />
Maximum: 2<strong>00</strong> ppm<br />
Expected s<strong>en</strong>sor life: > 36 months<br />
Lower detection limit: 3 ppm<br />
<strong>1089</strong> <strong>0707</strong> 01<br />
<strong>1089</strong> <strong>0707</strong> 02
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 2(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Gas measuring s<strong>en</strong>sor<br />
Calibration interval:<br />
Minimum 1 day<br />
Default 9 months<br />
Maximum 18 months<br />
Temperature:<br />
Operating: - 40°C to 60°C<br />
Storage: 0°C to 40°C<br />
Working pressure:<br />
7<strong>00</strong>mbar to 13<strong>00</strong>mbar<br />
Type: SO2<br />
Ref.: 6809660<br />
Measuring range:<br />
Minimum: 5 ppm<br />
Default: 10 ppm<br />
Maximum: 1<strong>00</strong> ppm<br />
Expected s<strong>en</strong>sor life: > 24 months<br />
Lower detection limit: 0.5 ppm<br />
Type: CO<br />
Ref.: 6809605<br />
Measuring range:<br />
Minimum: 0 to 50 ppm<br />
Default: 0 to 3<strong>00</strong> ppm<br />
Maximum: 0 to 1<strong>00</strong>0 ppm<br />
Expected s<strong>en</strong>sor life: > 36 months<br />
Lower detection limit: 5 ppm<br />
Type: O2 - LS<br />
Ref.: 6909630<br />
Measuring range:<br />
Minimum: 0 to 5% O2 by vol.<br />
Default: 0 to 25% O2 by vol.<br />
Maximum: 0 to 25 O2 by vol.<br />
Expected s<strong>en</strong>sor life: > 36 months<br />
Lower detection limit:<br />
≤ ± 0.3% by vol.<br />
<strong>1089</strong> <strong>0707</strong> 03<br />
<strong>1089</strong> <strong>0707</strong> 04<br />
<strong>1089</strong> <strong>0707</strong> 05
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Internal name + designation :<br />
Module + Article number<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 3(8)<br />
Measuring unit<br />
Technical data Article number<br />
Common data Distinction data<br />
Polytron 3<strong>00</strong>0 measuring unit<br />
Output: 4 to 20mA<br />
Power supply: 12 to 30VDC, 2-wire<br />
Enclosure: IP 66/67<br />
Weight (approx.): 9<strong>00</strong>g<br />
Approvals:<br />
ATEX: II 1G EEx ia IIC T6 / T4<br />
(-40 to +40 / 65°C)<br />
II 3G EEx nL IIC T6 / T4<br />
(-25 to +40 / 65°C)<br />
IECEx: EEx ia IIC T6 / T4<br />
(-40 to +40 / 65°C)<br />
UL: Class I, Div 1,<br />
Group A,B,C,D<br />
Class II, Div 1,<br />
Group E, F, G<br />
(T6 / T4: -40 to +40 / 65°C)<br />
CSA: Class I, Div 1,<br />
Group A, B, C, D<br />
Ex ia T6/T4<br />
(-40 to +40/65°C)<br />
CE: directive 89/336/EEC<br />
CO 1<strong>00</strong> ppm with display<br />
Ref.: 8316632<br />
CO 1<strong>00</strong> ppm non display<br />
Ref.: 8316732<br />
NO LC 50 ppm non display<br />
Ref.: 8316740<br />
NO2 10 ppm non display<br />
Ref.: 8316741<br />
SO2 10 ppm non display<br />
Ref.: 8316746<br />
O2 25 vol.-% non display<br />
Ref.: 8316745<br />
<strong>1089</strong> <strong>0707</strong> 11<br />
<strong>1089</strong> <strong>0707</strong> 12<br />
<strong>1089</strong> <strong>0707</strong> 13<br />
<strong>1089</strong> <strong>0707</strong> 14<br />
<strong>1089</strong> <strong>0707</strong> 15<br />
<strong>1089</strong> <strong>0707</strong> 16
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Internal name + designation :<br />
Mounting + Article number<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 4(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Polytron docking station<br />
Ref.: 8317990 <strong>1089</strong> <strong>0707</strong> 21<br />
Mounting cradle for measuring unit<br />
Polytron 7<strong>00</strong>0 and Polytron 3<strong>00</strong>0<br />
Size (H x W x D, approx.):<br />
170 x 130 x130 mm
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Internal name + designation :<br />
Filter + Article number<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 5(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Selective filter for gas measuring<br />
s<strong>en</strong>sor<br />
Removes specific interfer<strong>en</strong>t gases<br />
with little effect on the gas to be<br />
measured<br />
Oxidation filter A2F for s<strong>en</strong>sor CO<br />
and CO LS<br />
Ref.: 6809684<br />
Reaction filter K1F for s<strong>en</strong>sor SO2<br />
Ref.: 6809663<br />
Reaction filter CF for s<strong>en</strong>sor NO2<br />
Ref.: 6809658<br />
Dust filter for O2 and NO<br />
Ref.: 6809595<br />
<strong>1089</strong> <strong>0707</strong> 31<br />
<strong>1089</strong> <strong>0707</strong> 32<br />
<strong>1089</strong> <strong>0707</strong> 33<br />
<strong>1089</strong> <strong>0707</strong> 34
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Internal name + designation :<br />
Adapter + Article number<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 6(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Gasing process adapter<br />
Ref.: 6806978 <strong>1089</strong> <strong>0707</strong> 41<br />
For transmitters with<br />
electrochemical s<strong>en</strong>sors (not type<br />
L), catalytic bead s<strong>en</strong>sors<br />
(Pellistors) and Polytron IR CO2<br />
and polytron Ex HC.
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Internal name + designation :<br />
Polytron IR CO2<br />
Transmitter + Article number<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 7(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Measuring range:<br />
0 to 1…30 vol%<br />
0 to 2<strong>00</strong>0…9999 ppm<br />
Output: 4 to 20mA<br />
Power supply: 13 to 30VDC, 3-wire<br />
Temperature: -20 to 65°C<br />
Enclosure: IP65<br />
Weight: 1.9kg<br />
Size: 205 x 120 x 90 mm<br />
Approvals:<br />
CENELEC EEx em [ib] d IIb +<br />
H2 T4<br />
CE: directive 89/336/EEC<br />
Transmitter IR CO2 NDH, without<br />
display<br />
Ref.: 8316039<br />
<strong>1089</strong> <strong>0707</strong> 51
Edition check<br />
- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />
- Internet URL http://atlascopco.com/gsd<br />
GROUP<br />
STANDARDS<br />
DEPARTMENT ©<br />
Internal name + designation :<br />
Adapter + Article number<br />
Published by : AIRPOWER STANDARDS DEPARTMENT<br />
TECHNICAL SPECIFICATION<br />
<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />
Datum / date Uitgave / edition Blad / page<br />
2<strong>00</strong>7-11-28 4 8(8)<br />
Technical data Article number<br />
Common data Distinction data<br />
Adapter Polytron IR Ex and<br />
Polytron IR CO2<br />
Ref.: 6809240<br />
Connection for unit with gasing<br />
process adapter, splash guard or<br />
remote calibration adapter<br />
<strong>1089</strong> <strong>0707</strong> 61