Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

SENSOR<br />

DRÄGER<br />

S<strong>en</strong>sor + Article number<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 1(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Gas measuring s<strong>en</strong>sor<br />

Calibration interval:<br />

Minimum 1 day<br />

Default 6 months<br />

Maximum 12 months<br />

Temperature:<br />

Operating: - 40°C to 65°C<br />

Storage: 0°C to 40°C<br />

Working pressure:<br />

7<strong>00</strong>mbar to 13<strong>00</strong>mbar<br />

Type: NO2<br />

Ref.: 6809655<br />

Measuring range:<br />

Minimum: 5 ppm<br />

Default: 10 ppm<br />

Maximum: 1<strong>00</strong> ppm<br />

Expected s<strong>en</strong>sor life: > 18 months<br />

Lower detection limit: 0.3 ppm<br />

Including reaction filter CF<br />

Type: NO<br />

Ref.: 6809625<br />

Measuring range:<br />

Minimum: 30 ppm<br />

Default: 50 ppm<br />

Maximum: 2<strong>00</strong> ppm<br />

Expected s<strong>en</strong>sor life: > 36 months<br />

Lower detection limit: 3 ppm<br />

<strong>1089</strong> <strong>0707</strong> 01<br />

<strong>1089</strong> <strong>0707</strong> 02


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 2(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Gas measuring s<strong>en</strong>sor<br />

Calibration interval:<br />

Minimum 1 day<br />

Default 9 months<br />

Maximum 18 months<br />

Temperature:<br />

Operating: - 40°C to 60°C<br />

Storage: 0°C to 40°C<br />

Working pressure:<br />

7<strong>00</strong>mbar to 13<strong>00</strong>mbar<br />

Type: SO2<br />

Ref.: 6809660<br />

Measuring range:<br />

Minimum: 5 ppm<br />

Default: 10 ppm<br />

Maximum: 1<strong>00</strong> ppm<br />

Expected s<strong>en</strong>sor life: > 24 months<br />

Lower detection limit: 0.5 ppm<br />

Type: CO<br />

Ref.: 6809605<br />

Measuring range:<br />

Minimum: 0 to 50 ppm<br />

Default: 0 to 3<strong>00</strong> ppm<br />

Maximum: 0 to 1<strong>00</strong>0 ppm<br />

Expected s<strong>en</strong>sor life: > 36 months<br />

Lower detection limit: 5 ppm<br />

Type: O2 - LS<br />

Ref.: 6909630<br />

Measuring range:<br />

Minimum: 0 to 5% O2 by vol.<br />

Default: 0 to 25% O2 by vol.<br />

Maximum: 0 to 25 O2 by vol.<br />

Expected s<strong>en</strong>sor life: > 36 months<br />

Lower detection limit:<br />

≤ ± 0.3% by vol.<br />

<strong>1089</strong> <strong>0707</strong> 03<br />

<strong>1089</strong> <strong>0707</strong> 04<br />

<strong>1089</strong> <strong>0707</strong> 05


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Module + Article number<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 3(8)<br />

Measuring unit<br />

Technical data Article number<br />

Common data Distinction data<br />

Polytron 3<strong>00</strong>0 measuring unit<br />

Output: 4 to 20mA<br />

Power supply: 12 to 30VDC, 2-wire<br />

Enclosure: IP 66/67<br />

Weight (approx.): 9<strong>00</strong>g<br />

Approvals:<br />

ATEX: II 1G EEx ia IIC T6 / T4<br />

(-40 to +40 / 65°C)<br />

II 3G EEx nL IIC T6 / T4<br />

(-25 to +40 / 65°C)<br />

IECEx: EEx ia IIC T6 / T4<br />

(-40 to +40 / 65°C)<br />

UL: Class I, Div 1,<br />

Group A,B,C,D<br />

Class II, Div 1,<br />

Group E, F, G<br />

(T6 / T4: -40 to +40 / 65°C)<br />

CSA: Class I, Div 1,<br />

Group A, B, C, D<br />

Ex ia T6/T4<br />

(-40 to +40/65°C)<br />

CE: directive 89/336/EEC<br />

CO 1<strong>00</strong> ppm with display<br />

Ref.: 8316632<br />

CO 1<strong>00</strong> ppm non display<br />

Ref.: 8316732<br />

NO LC 50 ppm non display<br />

Ref.: 8316740<br />

NO2 10 ppm non display<br />

Ref.: 8316741<br />

SO2 10 ppm non display<br />

Ref.: 8316746<br />

O2 25 vol.-% non display<br />

Ref.: 8316745<br />

<strong>1089</strong> <strong>0707</strong> 11<br />

<strong>1089</strong> <strong>0707</strong> 12<br />

<strong>1089</strong> <strong>0707</strong> 13<br />

<strong>1089</strong> <strong>0707</strong> 14<br />

<strong>1089</strong> <strong>0707</strong> 15<br />

<strong>1089</strong> <strong>0707</strong> 16


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Mounting + Article number<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 4(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Polytron docking station<br />

Ref.: 8317990 <strong>1089</strong> <strong>0707</strong> 21<br />

Mounting cradle for measuring unit<br />

Polytron 7<strong>00</strong>0 and Polytron 3<strong>00</strong>0<br />

Size (H x W x D, approx.):<br />

170 x 130 x130 mm


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Filter + Article number<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 5(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Selective filter for gas measuring<br />

s<strong>en</strong>sor<br />

Removes specific interfer<strong>en</strong>t gases<br />

with little effect on the gas to be<br />

measured<br />

Oxidation filter A2F for s<strong>en</strong>sor CO<br />

and CO LS<br />

Ref.: 6809684<br />

Reaction filter K1F for s<strong>en</strong>sor SO2<br />

Ref.: 6809663<br />

Reaction filter CF for s<strong>en</strong>sor NO2<br />

Ref.: 6809658<br />

Dust filter for O2 and NO<br />

Ref.: 6809595<br />

<strong>1089</strong> <strong>0707</strong> 31<br />

<strong>1089</strong> <strong>0707</strong> 32<br />

<strong>1089</strong> <strong>0707</strong> 33<br />

<strong>1089</strong> <strong>0707</strong> 34


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Adapter + Article number<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 6(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Gasing process adapter<br />

Ref.: 6806978 <strong>1089</strong> <strong>0707</strong> 41<br />

For transmitters with<br />

electrochemical s<strong>en</strong>sors (not type<br />

L), catalytic bead s<strong>en</strong>sors<br />

(Pellistors) and Polytron IR CO2<br />

and polytron Ex HC.


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Polytron IR CO2<br />

Transmitter + Article number<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 7(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Measuring range:<br />

0 to 1…30 vol%<br />

0 to 2<strong>00</strong>0…9999 ppm<br />

Output: 4 to 20mA<br />

Power supply: 13 to 30VDC, 3-wire<br />

Temperature: -20 to 65°C<br />

Enclosure: IP65<br />

Weight: 1.9kg<br />

Size: 205 x 120 x 90 mm<br />

Approvals:<br />

CENELEC EEx em [ib] d IIb +<br />

H2 T4<br />

CE: directive 89/336/EEC<br />

Transmitter IR CO2 NDH, without<br />

display<br />

Ref.: 8316039<br />

<strong>1089</strong> <strong>0707</strong> 51


Edition check<br />

- Lotus Notes data base Standard Docum<strong>en</strong>ts - GSD<br />

- Internet URL http://atlascopco.com/gsd<br />

GROUP<br />

STANDARDS<br />

DEPARTMENT ©<br />

Internal name + designation :<br />

Adapter + Article number<br />

Published by : AIRPOWER STANDARDS DEPARTMENT<br />

TECHNICAL SPECIFICATION<br />

<strong>en</strong> <strong>1089</strong> <strong>0707</strong> <strong>00</strong><br />

Datum / date Uitgave / edition Blad / page<br />

2<strong>00</strong>7-11-28 4 8(8)<br />

Technical data Article number<br />

Common data Distinction data<br />

Adapter Polytron IR Ex and<br />

Polytron IR CO2<br />

Ref.: 6809240<br />

Connection for unit with gasing<br />

process adapter, splash guard or<br />

remote calibration adapter<br />

<strong>1089</strong> <strong>0707</strong> 61