TECHNICAL DATA Unit of measurement vICTRIx 50 vICTRIx 75 vICTRIx 90 vICTRIx 115 Maximum nominal heat input kW 50,8 74,6 92,3 110,7 Minimum nominal heat input kW 10,4 18,5 23,0 29,4 Maximum nominal heat output (80/60 °C) kW 50,0 72,6 90,0 109,0 Maximum nominal heat output (40/30 °C) kW 54,4 79,8 100,3 120,3 Minimum nominal heat output (80/60 °C) kW 10,0 18,1 22,5 28,8 Efficiency at nominal heat output (80/60 °C) % 98,5 97,3 97,5 98,4 Efficiency at minimum heat output (80/60 °C) % 96,0 97,6 97,8 98,0 Efficiency at nominal heat output (50/30 °C) % 106,0 104,5 106,0 106,9 Efficiency at minimum heat output (50/30 °C) % 106,5 106,3 108,2 108,2 Efficiency at nominal heat output (40/30 °C) % 107,0 107,0 108,7 108,7 Efficiency at minimum heat output (40/30 °C) % 107,0 107,0 109,1 109,6 Stack losses with burner on % 1,3 2,3 1,8 1,8 Stack losses with burner off % 0,02 0,01 0,01 0,01 Casing losses with burner on % 0,2 0,4 0,7 0,2 Casing losses with burner off % 0,47 0,32 0,41 0,28 Gas consumption at nominal heat output with natural gas m 3 /h 5,37 7,90 9,77 11,72 Fumes temperature at max. nominal heat input °C 41 62 52 52 Fumes temperature at min. nominal heat input °C 47 48 49 45 Fumes flow rate at max. nominal heat input kg/h 81 120 148 175 Fumes flow rate at min. nominal heat input kg/h 17 31 38 49 CO2 at maximum heat input % 9,3 9,2 9,3 9,45 CO2 at minimum heat input % 9,2 8,9 9,1 8,95 CO at maximum heat input with 0% of O2 ppm 130 170 180 175 CO at minimum heat input with 0% of O2 ppm 5 7 10 8 NOx at maximum heat input with 0% of O2 mg/kWh 69 53 37 49 NOx at minimum heat input with 0% of O2 mg/kWh 28 28 14 20 Weighted CO mg/kWh 37,6 43,0 20,0 19,0 Weighted NOx mg/kWh 38,5 40,0 23,3 28,0 NOx class - 5 5 5 5 Central heating temperature range °C 20–85 20–85 25–85 25–85 Maximum heating temperature °C 90 90 90 90 Maximum operating pressure bar 4,4 4,4 4,4 4,4 Available head with 1000 l/h flow rate Dimensions kPa 55,4 65,5 87,7 92,18 Height mm 950 950 1010 1010 Width mm 600 600 600 600 Depth mm 525 525 610 610 Electrical supply V/Hz 230/50 230/50 230/50 230/50 Nominal power draw A 0,85 1,26 1,69 1,80 Installed electric power W 180 270 370 390 Fan power consumption W 59 72 102 117 Circulator power consumption W 115 168 238 242 Protection index IP X5D X5D X5D X5D Boiler water content litres 3,7 4,0 10,1 11,7 Full appliance weight Kg 66 72 107 117,2 18
VICTRIX 115/90 main dimensions and connections 2035 1851 140 251 610 253 1 /2 G 2 ” 200 169 182 385 905 170 220 222 390 160 200 170 184 395 982 1 G 1 /2 ” G 1 ” G 1” 1 G 1 /2 ” 1 G 2 /2 ” 390 110 1 G 2 /2 ” 110 1 G 2 /2 ” 1 G 1 /2 ” G 1 ” 1 G 1 /2 ” 3 G /4 ” 3 G /4 ” G 1” SINGLE INSTALLATION VICTRIX 75/50 main dimensions and connections 19