12. Quality assurance<br />

The quality awareness is constantly increasing in<br />

the industry. The keys for your ambition are setting<br />

the right torque on all your power tools, calibration<br />

of transducerized tools together with static<br />

installed torque after checks on your applications.<br />

The industrially designed ACTA 3000 together with<br />

the ToolsTalk ACTA software provide you with one<br />

tool management and application management<br />

system. All information of your tools, applications<br />

and tightenings can be stored in one single database<br />

and more important, is easily retrieved and<br />

analyzed.<br />

Our quality assurance and control systems are designed<br />

specifi cally for ensuring that our customers can satisfy<br />

the current requirements of ISO 9001:2000 and ISO<br />

16949. Every product that leaves a production line<br />

should be checked and tested to ensure that every joint<br />

was tightened to the exact specifi cations. Tightening<br />

tolerances vary from one tool and tightening operation<br />

to the next and depend on both product and the purpose<br />

of its use. The many and often complex variables<br />

require a system that is transparent, easy to use and<br />

reliable – a system that eliminates the expensive<br />

consequences of faults and guarantees fault-free<br />

tightening performance in daily use. The combination<br />

of a quality tightening system and tool database<br />

guarantee peak tool performance.<br />

12.1 The ACTA 3000 for statistical<br />

evaluation of the tightening processes<br />

Measuring device for recording torque, rotational angle,<br />

number of pulses and speed. With large LCD display.<br />

The device is equipped with rechargeable batteries and<br />

is therefore suitable for mobile application. For checking<br />

the correct torque setting of nutrunners in the<br />

production line and the tool performance as part of<br />

repairs.<br />

Able to store up to 12,000 tightening values. Able to<br />

manage up to 1,000 tools. Expanded statistics functions<br />

and confi gurable display.<br />

With serial interface for PC communication and printer<br />

interface. Automatic calibration with all <strong>Atlas</strong> <strong>Copco</strong><br />

transducers. This design has a graphic function and can<br />

record, display and print out tightening curves.<br />

Designation Ordering No.<br />

ACTA 3000 Basic 8092 1133 20<br />

ACTA 3000 QC 8092 1133 30<br />

ACTA 3000 AA 8092 1133 40<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!