8 PUMP HEAD/FLOW RATE GRAPHICS<br />

The "<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> / <strong>kW</strong> X” series boilers are<br />

supplied with pump incorporated with electric three-speed<br />

adjuster plus automatic speed (factory-set). The automatic<br />

speed decides the most suitable setting for the pump on the<br />

basis of the ∆T measured between system flow and return.<br />

The pump is already equipped with a condenser.<br />

8.1 <strong>VICTRIX</strong> <strong>Superior</strong> 32 <strong>kW</strong> - 32 <strong>kW</strong> X PUMP<br />

Head (kPa)<br />

D<br />

F<br />

C<br />

GRUNDFOS UPRO 15-70 AO HB<br />

A<br />

E<br />

8<br />

<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> <strong>Export</strong><br />

<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> X <strong>Export</strong><br />

The "<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> / <strong>kW</strong> X" series boilers have an<br />

adjustable by-pass that is set in the factory (screw turned by 1.5<br />

turns with respect to the adjustment screw that is completely<br />

unscrewed).<br />

The adjustment can be modified by acting on the screw located<br />

on the by-pass unit.<br />

Flow rate l/h<br />

A: Head available to the system at third speed with by-pass excluded (adjustment screw tightened fully home).<br />

B: Head available to the system at second speed with by-pass excluded (adjustment screw tightened fully home).<br />

C: Head available to the system at first speed with by-pass excluded (adjustment screw tightened fully home).<br />

D: Head available to the system at third speed (screw tightened by 1.5 turns with respect to the adjustment screw that<br />

is completely unscrewed).<br />

E: Head available to the system at second speed (screw tightened by 1.5 turns with respect to the adjustment screw that<br />

is completely unscrewed).<br />

F: Head available to the system at first speed (screw tightened by 1.5 turns with respect to the adjustment screw that is<br />

completely unscrewed).<br />

B<br />

Head (m H 2 O)