VICTRIX Superior kW Export VICTRIX Superior kW X ... - Immergas
VICTRIX Superior kW Export VICTRIX Superior kW X ... - Immergas
VICTRIX Superior kW Export VICTRIX Superior kW X ... - Immergas
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
10 <strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> X WIRING DIAGRAM<br />
ROOM THERMOSTAT OR REMOTE CONTROL<br />
The Comando Amico Remoto (CAR) remote control or<br />
the Super Comando Amico Remoto remote control, must<br />
be connected to terminals 42 and 43 of the connector X15<br />
on the integrated P.C.B. respecting polarity and eliminating<br />
Brown<br />
Blue<br />
Blue<br />
Brown<br />
White<br />
Violet<br />
Black<br />
STORAGE<br />
TANK<br />
(optional)<br />
Blue<br />
Brown<br />
Black<br />
Power Supply<br />
230 Vac 50 Hz<br />
(D.H.W.)<br />
White<br />
Red (C.H.)<br />
White<br />
White<br />
Super CAR<br />
(optional)<br />
10<br />
<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> <strong>Export</strong><br />
<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> X <strong>Export</strong><br />
jumper X40.<br />
The boiler is designed to use the Room Thermostat (S20).<br />
Connect the room thermostat to terminals 40 and 41 of the<br />
connector X15 eliminating jumper X40.<br />
Any external probe (B4) must be connected to terminals 38<br />
and 39 of the connector X15 on the integrated P.C.B.<br />
KEY:<br />
A4 - Display board<br />
G2 - Igniter<br />
B1 - Flow probe<br />
M1 - Boiler pump<br />
B2 - D.H.W. probe (optional)<br />
M20 - Fan<br />
B4 - External probe (optional)<br />
M30 - 3-way valve (optional)<br />
B5 - Return probe<br />
R8 - Storage tank inibitor resistor<br />
CAR - Comando Amico Remoto remote control S5 - System pressure switch<br />
(optional)<br />
S20 - Room thermostat (optional)<br />
E1 - Ignition electrode<br />
Super CAR - SUPER Comando Amico Remoto<br />
E2 - Detection electrode<br />
remote control (optional)<br />
E4 - Safety thermostat<br />
T1 - Voltage transformer<br />
E6 - Flue safety thermostat<br />
X40 - Room thermostat jumper<br />
F1 - Line fuse<br />
Y1 - Gas valve<br />
Black<br />
Black<br />
Blue<br />
Blue<br />
White<br />
ZONE CONTROL<br />
UNIT(optional)<br />
White<br />
Grey<br />
Grey<br />
IMG BUS<br />
link<br />
Black<br />
Black<br />
White<br />
White<br />
Blue<br />
Brown<br />
FAN SPEED<br />
Storage Tank<br />
function jumper<br />
Blue<br />
Rose<br />
Orange<br />
White<br />
Black<br />
Red