15<br />

VICTRIX kW Export<br />

VICTRIX kW X Export<br />

15 VICTRIX 24 KW - 24 kW X COMBUSTION SPECIFICATIONS<br />

Natural gas<br />

(G20)<br />

The gas flow rates refer to the NHV at 15°C and with a 1013 mbar pressure.<br />

The fumes temperature values refer to a 15°C air inlet temperature and a delivery temperature of 50°C.<br />

LPG (G30) LPG (G31)<br />

100% Pn combustion efficiency (80/60°C) % 98.2 98.2 98.2<br />

P min combustion efficiency (80/60°C) % 98.3 98.3 98.3<br />

100% Pn operating performance (80/60°C) % 96.4 96.4 96.4<br />

P min operating performance (80/60°C) % 93.4 93.4 93.4<br />

100% Pn operating performance (50/30°C) % 104.9 104.9 104.9<br />

P min operating performance (50/30°C) % 105.0 105.0 105.0<br />

100% Pn operating performance (40/30°C) % 106.0 106.0 106.0<br />

P min operating performance (40/30°C) % 105.7 105.7 105.7<br />

Stack losses with burner on (100% Pn) (80/60°C) % 2.0 2.0 2.0<br />

Stack losses with burner on (P min) (80/60°C) % 1.7 1.7 1.7<br />

Stack losses with burner off % 0.15 0.15 0.15<br />

Outer casing losses with burner off % 0.05 0.05 0.05<br />

Outer casing losses with burner on (100% Pn) (80/60°C) % 1.8 1.8 1.8<br />

Outer casing losses with burner on (P min) (80/60°C) % 4.9 4.9 4.9<br />

Outlet flue temp. at maximum nominal heat input °C 54 60 55<br />

Outlet flue temp. at minimum nominal heat input °C 47 52 48<br />

Fumes flow rate at maximum heat input kg/h 40 35 40<br />

Fumes flow rate at maximum D.H.W. heat input kg/h 43 38 44<br />

Fumes flow rate at minimum heat input kg/h 8 7 8<br />

CO 2 at maximum heat input – C.H. % 9.35 12.25 10.45<br />

CO 2 at maximum heat input – D.H.W. % 9.40 12.25 10.40<br />

CO 2 at minimum heat input % 8.90 11.90 10.20<br />

CO at maximum heat input mg/kWh 208 595 190<br />

CO at minimum heat input mg/kWh 5 7 5<br />

NO x at maximum heat input mg/kWh 35 143 36<br />

NO x at minimum heat input mg/kWh 16 48 27<br />

CO weighted mg/kWh 58 - -<br />

NO x weighted mg/kWh 37 - -<br />

NO x category - 5 5 5