14<br />

VICTRIX kW Export<br />

VICTRIX kW X Export<br />

14 VICTRIX 24 kW X TECHNICAL SPECIFICATIONS<br />

VICTRIX 24 kW X<br />

Maximum nominal d.h.w. heat input kW (kcal/h) 27.0 (23,219)<br />

Maximum nominal central heating heat input kW (kcal/h) 24.9 (21,401)<br />

Maximum nominal d.h.w. heat output kW (kcal/h) 26.0 (22,337)<br />

Maximum nominal central heating output kW (kcal/h) 24.0 (20,640)<br />

Minimum nominal heat input kW (kcal/h) 5.0 (4,328)<br />

Minimum nominal output power kW (kcal/h) 4.7 (4,042)<br />

Efficiency at 100% Pn (80/60°C) % 96.4<br />

Efficiency at 30% of load (80/60°C) % 94.5<br />

Efficiency at 100% Pn (50/30°C) % 104.9<br />

Efficiency at 30% of load (50/30°C) % 104.5<br />

Efficiency at 100% Pn (40/30°C) % 106.0<br />

Efficiency at 30% of load (40/30°C) % 106.0<br />

Central heating circuit<br />

C.H. temperature adjustment (range 1 / range 2) °C 25 - 85 / 25 - 50<br />

Max system operating temperature °C 90<br />

Max system operating pressure bar bar 3<br />

System expansion vessel nominal capacity/ (actual) litres 8 / (5.7)<br />

System expansion vessel preload pressure bar 1.0<br />

Head available with a flow rate of 1000 l/h kPa (m H 2 O) 20,50 (2,09)<br />

Domestic Hot Water circuit (combined with the Storage Tank)<br />

D.H.W. useful thermal power kW (kcal/h) 26.0 (22,337)<br />

Specific flow rate x 10 min. (∆t 30°C) ST 80 litres litres/min 20.2<br />

Specific flow rate x 10 min. (∆t 30°C) ST 105 litres litres/min 22.0<br />

Specific flow rate x 10 min. (∆t 30°C) ST 120 litres litres/min 25.3<br />

Specific flow rate x 10 min. (∆t 30°C) ST 200 litres litres/min 35.9<br />

Flow rate for continuous service with ST (∆t 30°C) litres/min 12.8<br />

Gas supply<br />

NATURAL GAS (G20) MIN - MAX mbar 0.47 - 6.17 (7.20 D.H.W.)<br />

nozzles n°- ø mm 1 x 5.30<br />

LPG (G30) MIN - MAX mbar 0.42 - 6.18 (7.30 D.H.W.)<br />

nozzles n°- ø mm 1 x 3.85<br />

LPG (G31) MIN - MAX mbar 0.40 - 7.07 (8.40 D.H.W.)<br />

nozzles n°- ø mm 1 x 3.85<br />

Electricity supply V/Hz 230 - 50<br />

Nominal power draw A 0.60<br />

Installed electric power W 130<br />

Fan power consumption W 23<br />

Circulator power consumption W 78<br />

Electric protection level IP X4D<br />

Boiler water content litri 3.3<br />

Empty boiler weight kg 45.0<br />