10 VICTRIX 24 kW X WIRING DIAGRAM<br />
ROOM THERMOSTAT OR REMOTE CONTROL<br />
The boiler is designed to have the Remote Control (CAR)<br />
installed. Connect it to terminals 42 and 43 on the low voltage<br />
terminal block, observing polarity and removing jumper<br />
X40.<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
LEGEND:<br />
A4 - Display board<br />
B1 - Delivery probe<br />
B2 - D.h.w. probe (optional)<br />
B4 - External probe (optional)<br />
CAR - Remote Control (optional)<br />
E1 - Ignition electrodes<br />
E2 - Detection electrode<br />
E4 - Safety thermostat<br />
E6 - Flue safety thermostat<br />
G2 - Igniter<br />
M1 - Boiler circulator<br />
M20 - Fan<br />
M30 - 3-way valve (optional)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
10<br />
VICTRIX kW Export<br />
VICTRIX kW X Export<br />
The boiler is designed to have the Room Thermostat (S20)<br />
installed. Connect it to terminals 40 and 41 on the low voltage<br />
terminal block, removing jumper X40. If there is an External<br />
Probe (B4) connect it to terminals 38 and 39, again on the<br />
low voltage terminal block.<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
R8 - Storage tank inhibition resistance<br />
S2 - Functioning knob<br />
S5 - System pressure switch<br />
S7 - Heating timer selector<br />
S10 - Circulator mode selector<br />
S13 - Heating temperature range selector<br />
S20 - Room thermostat (optional)<br />
T1 - Low voltage transformer<br />
U1 - Rectifier inside the gas valve connector<br />
X40 - Room thermostat jumper<br />
Y1 - Gas valve