8 COMBUSTION SPECIFICATIONS<br />

8<br />

<strong>EOLO</strong> <strong>Star</strong> <strong>23</strong> <strong>kW</strong><br />

Nat. gas (G20) LPG (G30) LPG (G31)<br />

100% Pn combustion efficiency % 92.5 92.5 92.5<br />

P min combustion efficiency % 86.1 86.1 86.1<br />

Stack losses with burner on (100% Pn) % 7.5 7.5 7.5<br />

Stack losses with burner on (P min) % 13.9 13.9 13.9<br />

Stack losses with burner off % 0.02 0.02 0.02<br />

Outer casing losses with burner off % 0.53 0.53 0.53<br />

Outer casing losses with burner on (100% Pn) % 2.1 2.1 2.1<br />

Outer casing losses with burner on (P min) % 3.4 3.4 3.4<br />

Exhaust flue temp. at Max. nominal heat input °C 122 122 1<strong>23</strong><br />

Exhaust flue temp. at Min. nominal heat input °C 100 101 100<br />

Fumes flow rate at Max. nominal heat input kg/h 58 56 56<br />

Fumes flow rate at Min. nominal heat input kg/h 61 61 61<br />

CO 2 at Maximum Heat Input % 6.30 7.60 7.50<br />

CO 2 at Minimum Heat Input % 2.50 2.90 2.90<br />

CO at Maximum Heat Input mg/<strong>kW</strong>h 62 119 69<br />

CO at Minimum Heat Input mg/<strong>kW</strong>h 75 88 83<br />

NO x at Maximum Heat Input mg/<strong>kW</strong>h 120 405 356<br />

NO x at Minimum Heat Input mg/<strong>kW</strong>h 88 240 183<br />

Weighted CO mg/<strong>kW</strong>h 89 - -<br />

Weighted NO x mg/<strong>kW</strong>h 106 - -<br />

NO x category - 3 3 3<br />

The gas flow rates refer to the NHV at 15°C and with 1013 mbar pressure.<br />

The fumes temperature values refer to a 15°C inlet air temperature.