Hydraulic system 48 Immergas | Catalogue ʻ09 Description Code Safety kit for single boiler 3.015222 (it includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressostat, gas intercepting valve trap, expansion vessel connection) Three-way valve kit connection to the separate storage tank 3.015223 (it includes the storage tank probe) Hydraulic manifold kit for single boiler 3.015224 to allow rise in head/flow rate of the system (it includes a mud-filter on the return pipe) Hydraulic manifold kit for 2 boilers in cascade 3.015225 (including the intercepting valve and the non-return for each appliance) Hydraulic manifold kit for additional boiler in cascade 3.015226 (including the intercepting valve and the non-return valve) Safety kit for boilers in cascade 3.015227 (it includes thermometer, thermometer holder, lock thermostat with manual reset, connection tap for pressure gauge, manual reset pressostat, gas intercepting valve trop, expansion vessel connection) Low temperature second zone kit 3.018836 High temperature second zone kit 3.018837
VICTRIX Zeus Superior kW VICTRIX Zeus VICTRIX Superior kW VICTRIX VICTRIX 50&75 • • • • • • VICTRIX Superior kW X VICTRIX X HERCULES Condensing • • ZEUS Superior kW AVIO/ZEUS kW EOLO Maior kW NIKE/EOLO Mini kW Special NIKE/EOLO Mini kW NIKE/EOLO Star EOLO Maior kW X NIKE/EOLO Mini kW S EOLO Extra kW UB80 UB105 UB120 UB200 Catalogue ʻ09 | Immergas 49
- Page 1: CATALOGUE Gas boilers and condensin
- Page 4 and 5: NEW VICTRIX Zeus Superior kW Heat o
- Page 6 and 7: VICTRIX Superior kW Heat output of
- Page 8 and 9: VICTRIX 115 Heat output of 115 kW;
- Page 10 and 11: VICTRIX 75 Heat outputs of 75 kW; H
- Page 12 and 13: VICTRIX Superior kW X Heat output o
- Page 14 and 15: NEW HERCULES Condensing Heat output
- Page 16 and 17: AVIO/ZEUS kW Heat outputs of 24 and
- Page 18 and 19: NIKE/EOLO Mini kW Special Heat outp
- Page 20 and 21: NEW NIKE/EOLO Star Open chamber con
- Page 22 and 23: NIKE/EOLO Mini kW S Heat outputs of
- Page 24 and 25: JULIUS Star Wall-hung open chamber
- Page 26 and 27: IMMERSTOR Stainless steel storage t
- Page 28 and 29: FLUE SYSTEMS RANGE green series
- Page 30 and 31: Green Series Flue systems for VICTR
- Page 32 and 33: Green Series Flue System for Conden
- Page 34 and 35: Green Series Ø 60 mm ducting syste
- Page 36 and 37: Green Series Ø 80 mm flexible duct
- Page 39 and 40: FLUE SYSTEMS RANGE blue series
- Page 41 and 42: Blue Series Flue System for Traditi
- Page 43 and 44: Blue Series Flue System for Traditi
- Page 45 and 46: Blue Series Ø 80 mm ducting system
- Page 47: Blue Series Flue system components
- Page 52 and 53: Hydraulic system 50 Immergas | Cata
- Page 54 and 55: Hydraulic system 52 Immergas | Cata
- Page 56 and 57: Climatic regulation 54 Immergas | C
- Page 58 and 59: Climatic regulation 56 Immergas | C
- Page 60 and 61: Boilers and storage tank units conn
- Page 62 and 63: Index of codes Code Description 3.5
- Page 64 and 65: Code Description EAN code 3.014439
- Page 66: Code Description 3.018865 Boiler EO
Hydraulic system<br />
48 <strong>Immergas</strong> | Catalogue ʻ09<br />
Description Code<br />
Safety kit for single boiler 3.015222<br />
(it includes thermometer, thermometer holder, lock, thermostat<br />
with manual reset, connection tap for pressure gauge,<br />
manual reset pressostat, gas intercepting valve trap,<br />
expansion vessel connection)<br />
Three-way valve kit connection to the separate storage tank 3.015223<br />
(it includes the storage tank probe)<br />
Hydraulic manifold kit for single boiler 3.015224<br />
to allow rise in head/flow rate of the system<br />
(it includes a mud-filter on the return pipe)<br />
Hydraulic manifold kit for 2 boilers in cascade 3.015225<br />
(including the intercepting valve and the non-return<br />
for each appliance)<br />
Hydraulic manifold kit for additional boiler in cascade 3.015226<br />
(including the intercepting valve and the non-return valve)<br />
Safety kit for boilers in cascade 3.015227<br />
(it includes thermometer, thermometer holder, lock thermostat<br />
with manual reset, connection tap for pressure gauge,<br />
manual reset pressostat, gas intercepting valve trop,<br />
expansion vessel connection)<br />
Low temperature second zone kit 3.018836<br />
High temperature second zone kit 3.018837