7.2. Association Level Security Not applicable. 7.3. Application Level Security Not applicable. DICOM Conformance Statement Page 58 of 78 © Koninklijke Philips Electronics N.V. Document Number: XPR 031-090167.00 MammoDiagnost DR 1.0 18-March-2009
8. ANNEXES OF APPLICATION "ELEVA" 8.1. IOD Contents DICOM Conformance Statement Page 59 of 78 8.1.1. Created SOP Instance This section specifies each created IOD by this application. This section specifies each IOD created (including private IOD’s). It should specify the attribute name, tag, VR, and value. The value should specify the range and source (e.g. user input, Modality Worklist, automatically generated, etc.). For content items in templates, the range and source of the concept name and concept values should be specified. Whether the value is always present or not shall be specified. Abbreviations used in the IOD tables for the column "Presence of Module" are: ALWAYS The module is always present CONDITIONAL The module is used under specified condition Abbreviations used in the Module table for the column "Presence of Value" are: ALWAYS The attribute is always present with a value EMPTY The attribute is always present without any value (attribute sent zero length) VNAP The attribute is always present and its Value is Not Always Present (attribute sent zero length if no value is present) ANAP The attribute is present under specified condition – if present then it will always have a value ANAPCV The attribute is present under specified condition – if present then its Value is Not Always Present (attribute sent zero length if condition applies and no value is present) ANAPEV The attribute is present under specified condition – if present then it will not have any value The abbreviations used in the Module table for the column "Source" are: AUTO The attribute value is generated automatically CONFIG The attribute value source is a configurable parameter COPY The attribute value source is another SOP instance FIXED The attribute value is hard-coded in the application IMPLICIT The attribute value source is a user-implicit setting MPPS The attribute value is the same as that use for Modality Performed Procedure Step MWL The attribute value source is a Modality Worklist USER The attribute value source is explicit user input 8.1.1.1. List of created SOP Classes Table 57: List of created SOP Classes SOP Class Name SOP Class UID Digital Mammography X-Ray Image Storage - Pres. 1.2.840.10008.5.1.4.1.1.1.2 SOP Digital Mammography X-Ray Image Storage - Proc. 1.2.840.10008.5.1.4.1.1.1.2.1 SOP Computed Radiography Image Storage SOP Class 1.2.840.10008.5.1.4.1.1.1 © Koninklijke Philips Electronics N.V. Document Number: XPR 031-090167.00 MammoDiagnost DR 1.0 18-March-2009
- Page 7 and 8: 3. INTRODUCTION DICOM Conformance S
- Page 9 and 10: DICOM Conformance Statement Page 9
- Page 11 and 12: DICOM Conformance Statement Page 11
- Page 13 and 14: DICOM Conformance Statement Page 13
- Page 15 and 16: DICOM Conformance Statement Page 15
- Page 17 and 18: DICOM Conformance Statement Page 17
- Page 19 and 20: DICOM Conformance Statement Page 19
- Page 21 and 22: DICOM Conformance Statement Page 21
- Page 23 and 24: DICOM Conformance Statement Page 23
- Page 25 and 26: DICOM Conformance Statement Page 25
- Page 27 and 28: Service Status DICOM Conformance St
- Page 29 and 30: DICOM Conformance Statement Page 29
- Page 31 and 32: DICOM Conformance Statement Page 31
- Page 33 and 34: DICOM Conformance Statement Page 33
- Page 35 and 36: DICOM Conformance Statement Page 35
- Page 37 and 38: DICOM Conformance Statement Page 37
- Page 39 and 40: DICOM Conformance Statement Page 39
- Page 41 and 42: DICOM Conformance Statement Page 41
- Page 43 and 44: DICOM Conformance Statement Page 43
- Page 45 and 46: DICOM Conformance Statement Page 45
- Page 47 and 48: DICOM Conformance Statement Page 47
- Page 49 and 50: DICOM Conformance Statement Page 49
- Page 51 and 52: 4.3. Network Interfaces DICOM Confo
- Page 53 and 54: 5. MEDIA INTERCHANGE DICOM Conforma
- Page 55 and 56: DICOM Conformance Statement Page 55
- Page 57: 7. SECURITY 7.1. Security Profiles
- Page 61 and 62: DICOM Conformance Statement Page 61
- Page 63 and 64: DICOM Conformance Statement Page 63
- Page 65 and 66: DICOM Conformance Statement Page 65
- Page 67 and 68: DICOM Conformance Statement Page 67
- Page 69 and 70: DICOM Conformance Statement Page 69
- Page 71 and 72: DICOM Conformance Statement Page 71
- Page 73 and 74: DICOM Conformance Statement Page 73
- Page 75 and 76: View Position 0018,5101 CS VNAP DIC
- Page 77 and 78: Number of Films 2100,0170 IS DICOM
7.2. Association Level Security<br />
Not applicable.<br />
7.3. Application Level Security<br />
Not applicable.<br />
<strong>DICOM</strong> <strong>Conformance</strong> <strong>Statement</strong> Page 58 of 78<br />
© Koninklijke <strong>Philips</strong> Electronics N.V.<br />
Document Number: XPR 031-090167.00 MammoDiagnost DR 1.0 18-March-2009