DICOM Conformance Statement Page 14 of 78 4.2. AE Specifications This section in the DICOM Conformance Statement is a set of application entity specifications. There are as many of these subsections as there are different AEs in the implementation. 4.2.1. Eleva Detail of this specific Application Entity is specified in this section. 4.2.1.1. SOP Classes This Application Entity provides Standard Conformance to the following SOP Classes. Table 5: SOP Classes for Eleva SOP Class Name SOP Class UID SCU SCP Computed Radiography Image Storage SOP Class 1.2.840.10008.5.1.4.1.1.1 Yes No Digital Mammography X-Ray Image Storage - Pres. SOP 1.2.840.10008.5.1.4.1.1.1.2 Yes No Digital Mammography X-Ray Image Storage - Proc. SOP 1.2.840.10008.5.1.4.1.1.1.2.1 Yes No Modality Performed Procedure Step SOP Class 1.2.840.10008.3.1.2.3.3 Yes No Modality Worklist Information Model - FIND SOP Class 1.2.840.10008.5.1.4.31 Yes No Presentation LUT SOP Class 1.2.840.10008.5.1.1.23 Yes No Storage Commitment Push Model SOP Class 1.2.840.10008.1.20.1 Yes No Verification SOP Class 1.2.840.10008.1.1 Yes Yes Basic Grayscale Print Management Meta SOP Class 1.2.840.10008.5.1.1.9 Yes No >Basic Film Box SOP Class 1.2.840.10008.5.1.1.2 Yes No >Basic Film Session SOP Class 1.2.840.10008.5.1.1.1 Yes No >Basic Grayscale Image Box SOP Class 1.2.840.10008.5.1.1.4 Yes No >Printer SOP Class 1.2.840.10008.5.1.1.16 Yes No Note: Any SOP specific behavior is documented later in the conformance statement in the applicable SOP specific conformance section. 4.2.1.2. Association Policies Each AE specification contains a description of the general association establishment and acceptance policies of the AE. 4.2.1.2.1. General The DICOM standard application context has specified. Table 6: DICOM Application Context Description Value Application Context Name 1.2.840.10008.3.1.1.1 © Koninklijke Philips Electronics N.V. Document Number: XPR 031-090167.00 MammoDiagnost DR 1.0 18-March-2009
DICOM Conformance Statement Page 15 of 78 4.2.1.2.2. Number of Associations The number of simultaneous associations that an Application Entity may support as a Initiator or Acceptor is specified. Table 7: Number of Associations as an Association Initiator Description Value Maximum number of simultaneous associations 2 Table 8: Number of Associations as an Association Acceptor Description Value Maximum number of simultaneous assocations 1 4.2.1.2.3. Asynchronous Nature If the implementation supports negotiation of multiple outstanding transactions this is stated here, along with the maximum number of outstanding transactions supported. Table 9: Asynchronous Nature as an Association Initiator Description Value Maximum number of outstanding asynchronous transactions 0 4.2.1.2.4. Implementation Identifying Information The value supplied for Implementation Class UID and version name are documented here. Table 10: DICOM Implementation Class and Version for Eleva Implementation Class UID 1.3.46.670589.30.1.3 Implementation Version Name PMS_ELEVA_PA_2.1 4.2.1.2.5. Communication Failure Handling The behavior of the AE during communication failure is summarized in next table. Table 11: Communication Failure Behavior Exception Behavior ARTIM Timeout TBD 4.2.1.3. Association Initiation Policy The behavior of this Application Entity is summarized as shown in next Table. © Koninklijke Philips Electronics N.V. Document Number: XPR 031-090167.00 MammoDiagnost DR 1.0 18-March-2009
- Page 1 and 2: DICOM Conformance Statement © Koni
- Page 3 and 4: DICOM Conformance Statement Page 3
- Page 5 and 6: 2. TABLE OF CONTENTS DICOM Conforma
- Page 7 and 8: 3. INTRODUCTION DICOM Conformance S
- Page 9 and 10: DICOM Conformance Statement Page 9
- Page 11 and 12: DICOM Conformance Statement Page 11
- Page 13: DICOM Conformance Statement Page 13
- Page 17 and 18: DICOM Conformance Statement Page 17
- Page 19 and 20: DICOM Conformance Statement Page 19
- Page 21 and 22: DICOM Conformance Statement Page 21
- Page 23 and 24: DICOM Conformance Statement Page 23
- Page 25 and 26: DICOM Conformance Statement Page 25
- Page 27 and 28: Service Status DICOM Conformance St
- Page 29 and 30: DICOM Conformance Statement Page 29
- Page 31 and 32: DICOM Conformance Statement Page 31
- Page 33 and 34: DICOM Conformance Statement Page 33
- Page 35 and 36: DICOM Conformance Statement Page 35
- Page 37 and 38: DICOM Conformance Statement Page 37
- Page 39 and 40: DICOM Conformance Statement Page 39
- Page 41 and 42: DICOM Conformance Statement Page 41
- Page 43 and 44: DICOM Conformance Statement Page 43
- Page 45 and 46: DICOM Conformance Statement Page 45
- Page 47 and 48: DICOM Conformance Statement Page 47
- Page 49 and 50: DICOM Conformance Statement Page 49
- Page 51 and 52: 4.3. Network Interfaces DICOM Confo
- Page 53 and 54: 5. MEDIA INTERCHANGE DICOM Conforma
- Page 55 and 56: DICOM Conformance Statement Page 55
- Page 57 and 58: 7. SECURITY 7.1. Security Profiles
- Page 59 and 60: 8. ANNEXES OF APPLICATION "ELEVA" 8
- Page 61 and 62: DICOM Conformance Statement Page 61
- Page 63 and 64: DICOM Conformance Statement Page 63
<strong>DICOM</strong> <strong>Conformance</strong> <strong>Statement</strong> Page 15 of 78<br />
4.2.1.2.2. Number of Associations<br />
The number of simultaneous associations that an Application Entity may support as a<br />
Initiator or Acceptor is specified.<br />
Table 7: Number of Associations as an Association Initiator<br />
Description Value<br />
Maximum number of simultaneous associations 2<br />
Table 8: Number of Associations as an Association Acceptor<br />
Description Value<br />
Maximum number of simultaneous assocations 1<br />
4.2.1.2.3. Asynchronous Nature<br />
If the implementation supports negotiation of multiple outstanding transactions this is<br />
stated here, along with the maximum number of outstanding transactions supported.<br />
Table 9: Asynchronous Nature as an Association Initiator<br />
Description Value<br />
Maximum number of outstanding asynchronous transactions 0<br />
4.2.1.2.4. Implementation Identifying Information<br />
The value supplied for Implementation Class UID and version name are documented<br />
here.<br />
Table 10: <strong>DICOM</strong> Implementation Class and Version for Eleva<br />
Implementation Class UID 1.3.46.670589.30.1.3<br />
Implementation Version Name PMS_ELEVA_PA_2.1<br />
4.2.1.2.5. Communication Failure Handling<br />
The behavior of the AE during communication failure is summarized in next table.<br />
Table 11: Communication Failure Behavior<br />
Exception Behavior<br />
ARTIM Timeout TBD<br />
4.2.1.3. Association Initiation Policy<br />
The behavior of this Application Entity is summarized as shown in next Table.<br />
© Koninklijke <strong>Philips</strong> Electronics N.V.<br />
Document Number: XPR 031-090167.00 MammoDiagnost DR 1.0 18-March-2009