M12 Oncore Users Guide Supplement - deetc - isel
M12 Oncore Users Guide Supplement - deetc - isel
M12 Oncore Users Guide Supplement - deetc - isel
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Position Control Function Sets the positioning mode for the receiver.<br />
holdcon Syntax holdcon ([ 0 | 1 | 2 |)<br />
0 = no hold or normal positioning<br />
1 = enable position hold<br />
2 = enable altitude hold<br />
Example holdcon 1<br />
Notes None<br />
See Also None<br />
Binary Equivalent @@Gd<br />
Leap Second Pending Function Used to determine if there is a pending leap second correction<br />
leap12<br />
Syntax leap12<br />
Example leap12 <br />
Notes This is a polled-only output message. If a correction is pending, the<br />
direction of the correction is indicated.<br />
See Also None<br />
Binary Equivalent @@Gj<br />
ID Tag Function Sets or defaults the ID tag.<br />
vin<br />
Syntax vin ([ ++++++ ])<br />
++++++ ID tag will be receiver serial number<br />
6 spaces No change<br />
Motorola GPS Products<br />
<strong>M12</strong> <strong>Oncore</strong> User’s <strong>Guide</strong> <strong>Supplement</strong><br />
Revision 1.0 01/25/00<br />
COMMAND DESCRIPTIONS<br />
Example vin ++++++<br />
Notes None<br />
Any other combination of 6 ASCII characters (from 0x20 to<br />
0x7e0will be construed as a new ID tag. Any out of range character<br />
will cause the ID tag to remain unchanged.<br />
See Also Position/Status/Data Message (@@Ha)<br />
Binary Equivalent @@Gk<br />
123